Advertisement

Photograph 1- Location of the fan side auto resettable A60 over temperature switch, one
each side
Table3- Rating of the overheat switches
Temp/model
SS512e/i
Auto
3xA60
Manual
1xM80
2. Replacement of the flame sensor and or ignitor -
Open the two screws of the flame sensor shown through photograph 3 and replace or service the
flame sensor fitted on the front face of the burner top panel. The ignitor is located below the
burner bottom as shown in photograph 4. Just open the two screws and pull down the ignitor for
replacement. Make sure the ignitor lead of the replacement part is sleeved with a high voltage
suppression lead. Use genuine part of the appliance to avoid malfunction. Make sure the gap
between the electrodes tips is not tempered with.
Photograph 3- Location of the flame sensor
3. Pressure switch-
The heater will not work if the pressure switch is not operating properly. Please see that the flue
is not blocked in any way. Make sure the air pressure tube is connected at both ends and with
grey inlet of the switch and the spade connections are tight fit to make proper contacts. The
replacement pressure switch should be of the same rating and part number as specified in the
appliance. The switch can malfunction if it is not mounted and harnessed properly on the
specified location. The location of the pressure switch is given next to the combustion fan and is
shown through the photograph 5 and 6.
Eco Pacific/Super Star- Installation and Service Instructions 20173
SS516e/i and
HB416i
o
o
C
3xA60
C
o
o
C
1xM80
C
SS520e/i and
SS525e/i
HB420i
o
3xA80
C
3x80
o
1xM90
C
1x90
Photograph 4- Location of the igniter- top right end
SS530e/i
o
o
C
3x80
C
o
o
C
1x90
C
17