Circuit Diagram; Dimensional Drawing - Beckhoff AX2090-ND50 Documentation

Mains chokes
Table of Contents

Advertisement

3.1

Circuit diagram

Serious risk of injury!
Due to the DC link capacitors dangerous voltage (> 890V
tacts "ZK+ and ZK-"and "RB+ and RB-" after the servo drive has been disconnected from
DANGER
the mains supply. After disconnecting the servo drive wait at AX5160/AX5172; 15 minutes,
at AX5190/AX5191; 30 minutes and at AX5192/AX5193; 45 minutes and measure the volt-
age at the DC link contacts ZK+ and ZK-. The device is safe once the voltage has fallen be-
low 50 V.
Connection:
• Connect the protective conductor connection of the mains choke with the PE rail.
• Connect the connecting cable of the mains choke to the appropriate terminals of the servo drive.
• Connect the mains choke to the supply network.
3.2

Dimensional drawing

Dimension [mm]
0060
B (Wigth)
190
H (Height)
200
T (Depth)
120
A
170
C
68
D
8
Mains chokes AX2090-ND50
AX2090-ND50-
0072
0090
190
230
240
300
110
160
170
180
78
98
8
8
Version: 1.1
Installing the mains chokes
) may persist at the DC link con-
DC
0110
0143
230
240
300
330
180
200
180
190
122
125
8
11
0170
240
330
200
190
125
11
9

Advertisement