Technical Data - Beckhoff AX2090-ND50 Documentation

Mains chokes
Table of Contents

Advertisement

Technical data

4
Technical data
Ambient conditions
Rated voltage
Overload factor
Ambient temperature
Mounting height
Rel. air humidity
Storage temperature
Protection
Short circuit voltage
Permissible contamination
Thermal rating
Recognition
1)
at mains frequency = 60 Hz power loss approx. 10 % higher!
Three-phase mains chokes
Data
Rated current [A]
Power loss total [W]
Inductance [mH]
Weight [kg]
Connection [mm²]
Short-circuit voltage
10
Three-phase mains chokes AX2090-ND50
3 x 460 V, -25% +10%, 50/60 Hz
-25 °C to +45 °C, with 1,3% (/°C) power reduction to +60°C
1000 m, with 6% (/1000m) power reduction to 4000 m
15 %...95 %, no condensation permitted
0060
0072
60
72
70
80
0,25
0,20
7
10
16
16
Version: 1.1
2,0 x I
for 30 s
N
-25 °C to +70 °C
IP00
UK 4 % at 400 V = 9,24 V
UK 2 % at 400 V = 4,6 V
P2 to EN 61558-1
I
< I
eff
N
UL / CSA
AX2090-ND50-
0090
0110
90
110
120
140
0,16
0,13
13
15
35
35
4 % U
K
Mains chokes AX2090-ND50
1)
0143
0170
143
170
160
170
0,10
0,09
25
25
70
70

Advertisement

Table of Contents
loading

Table of Contents