Cattron Holdings, Inc., or any of its affiliates or agents shall not be liable for incidental or consequential damages of any kind. All Cattron products are sold pursuant to the Terms and Conditions of Sale, a copy of which will be furnished upon request. When used as a tradename herein, Cattron means Cattron Holdings, Inc.
® CommandPro General Purpose & Safety Applications User Manual Contents 1. Warnings ................................5 2. FCC Compliance Statement ..........................6 3. Safety Rules .................................7 3.1 Installation ..............................7 3.2 Personal Safety ............................7 3.3 Care ................................7 4. Introduction................................8 4.1 How the System Works ..........................8 4.1.1 Frequency ...............................8 4.1.2 Range and Antenna Coverage .......................8 4.1.3 License-Free Channels ...........................8...
Page 4
® CommandPro General Purpose & Safety Applications User Manual 6.2.2 Command Switches ..........................17 6.2.3 Auto OFF ............................. 17 6.3 Transmitter Operation..........................17 6.4 Transmitter Troubleshooting ........................17 6.4.1 Status LED ............................18 6.5 Replace the Batteries ..........................18 6.6 Changing the Transmitter Identity Codes ....................19 6.7 24T09 Specifications ..........................
Read all safety rules and warnings before installing and operating this system. WARNING The use of unapproved components or accessories in the systems sold by Cattron and its subsidiaries is strictly prohibited. Unapproved components are defined as any component not inspected and sold by Cattron.
® CommandPro General Purpose & Safety Applications User Manual FCC Compliance Statement ® The CommandPro Series receivers have been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
® CommandPro General Purpose & Safety Applications User Manual Safety Rules WARNING Read all Instructions. Failure to follow these rules can result in serious personal injury or death. Installation • GROUND THE RECEIVER CASE. In order to ensure safety of the system, firmly connect the receiver case to earth ground •...
The Cattron Safety Stop Remote Control System is designed to provide the means for an operator to remotely stop electrical equipment in times of emergency. The Safety Stop Remote Control System is used as a supplement to the hard wired Emergency Stop switch on equipment and not as a replacement for such function.
(described in the next section). 4.1.5 Safety Safety and preventing loss of control are very important issues at Cattron. We use a unique identification code for each user. There are provisions in the system for 65,535 individual codes. Each transmission includes a CRC check sum, which is a polynomial created by factoring all of the previous bits transmitted.
4.1.9 Options 4.1.9.1 Custom Transmitter Labels Custom switch labels are available from Cattron to best suit your application. 4.1.9.2 Custom Enclosure The receivers are normally supplied in a NEMA 4 steel enclosure. A number of other enclosures are available to meet special ratings.
This section describes the safety/operational features, troubleshooting and repair of the 22T10A transmitter. Cattron control transmitters are housed in a rugged polymer plastic IP67 compliant case that stands up to extremely rugged use. A key feature is our patented switch assembly for control inputs. This long-life elastomeric keypad is ergonomically designed to provide easy operation over long periods of time with exceptional reliability.
® CommandPro General Purpose & Safety Applications User Manual Figure 1: 22T10A Transmitter Maintained Link and Utility Mode Transmitter Safety and Operational Features The following describes the functions and operational features of the 22 Series transmitter. Refer to Figure 5.2.1 Status LED The status LED provides an indication of the transmitter operation.
® CommandPro General Purpose & Safety Applications User Manual Transmitter Operation (22T10A Maintained Link Mode) IMPORTANT To stop the system in an emergency, press and hold the OFF/STOP button. Pressing and holding this button down stops all functions. 1. Press and release the RADIO ON button. Verify that the status LED starts flashing at a low rate. Note: You must be within radio range at all times for the system to operate.
® CommandPro General Purpose & Safety Applications User Manual 5.4.1 Status LED Troubleshooting Chart LED Indications Possible Cause Transmitter is off – switch transmitter ON LED is Off Batteries are dead – replace batteries Transmitter failure – call for service Utility Mode TX LED flashes at low rate Transmitter is operating in a normal mode...
User Manual Changing the Transmitter Identity Codes Changing the ID Code requires use of a Cattron RAC16A Series Programmer. Refer to Figure 2 for the handheld transmitters. 1. Confirm that the batteries are fresh and the transmitter is off (refer to Troubleshooting).
This section describes the safety/operational features, troubleshooting and repair of the 24T09A transmitter. Cattron control transmitters are housed in a rugged case molded from a modified polymer plastic that stands up to extremely rugged use. A key feature is our patented switch assembly for control inputs. This long-life elastomeric keypad is ergonomically designed to provide easy operation over long periods of time with exceptional reliability.
® CommandPro General Purpose & Safety Applications User Manual ‘A’ Series IP67 rated Transmitters have a separate battery door. Note: Transmitter Safety and Operational Features The following sections describe the safety and operational features and characteristics of the transmitters. 6.2.1 Status LED The status LED provides an indication of the transmitter operation.
® CommandPro General Purpose & Safety Applications User Manual 6.4.1 Status LED LED Identification Possible Cause Transmitter is Off – switch transmitter On LED is Off Batteries are dead – replace batteries Transmitter failure – call for service In Utility Mode LED flashes at low rate Transmitter is operating in a normal mode LED flashes at high rate...
CommandPro General Purpose & Safety Applications User Manual Changing the Transmitter Identity Codes Changing the ID Code requires use of a Cattron RAC16A Series Programmer. Refer to Figure 3 Figure 4 your transmitter. 1. Confirm that the batteries are fresh (refer to the Transmitter Troubleshooting chart).
® CommandPro General Purpose & Safety Applications User Manual Receivers Receiver Description 22R08A The 22R08A receiver consists of a single RF/Relay Board mounted inside a NEMA 4 enclosure. In utility mode, the 22R08A has eight control relays. Typically, in maintained link mode, the 22R08A receiver has eight control relays configurable to customer applications and requires a continuously valid signal from the transmitter for the system to operate.
® CommandPro General Purpose & Safety Applications User Manual Figure 5: Receiver with NEMA 4 Enclosure Receiver Testing 7.2.1 Receiver LEDs Refer to Figure 5 for the locations of the decoder diagnostic LEDs inside the receiver enclosure. LED Indication Possible Cause POWER LED lit Receiver operating voltage is present SIGNAL LED flashes rapidly...
Verify that proper voltage is present at AC X1/+DC and AC X2/-DC. b. If voltage is present, check or replace F1. c. If POWER LED is not illuminated, send the receiver to Cattron for repair. 2. Activate the transmitter by pressing any command switch (press ‘ON’ in maintained link mode).
® CommandPro General Purpose & Safety Applications User Manual Receiver Repairs WARNING Remove external power to the receiver enclosure before performing electrical work inside the cabinet. Refer to Figure 7.4.1 Replacing the RF/Relay Board 1. Switch off power to the receiver and open the enclosure door. 2.
® CommandPro General Purpose & Safety Applications User Manual Item Detail Safety Features Address check CRC code check Format test Signal check Transmitter status checks Self-test Indicators Full function Diagnostics LEDs for easy troubleshooting Output Contacts 8 Amp @ 230 VAC in rush current Logic Base Programmable for each application Maximum Current Drain...
General Purpose & Safety Applications User Manual Warranty Statement For service and repairs, go to www.cattron.com/contact CE Declaration of Conformity Hereby Cattron declares that the radio equipment is in compliance with Directive 2014/53/EU. View the EU Declaration of Conformity document at www.cattron.com 9M02-9028-A031-EN Rev 4...
Page 26
Due to continuous product improvement, the information provided in this document is subject to change without notice. Cattron Support For remote and communication control systems support, parts and repair, or technical support, visit us online at: www.cattron.com/contact Cattron North America Inc., 655 N River Rd NW, Suite A, Warren, OH 44483 9M02-9028-A031-EN Rev 4...