Mikrofill Ethos Series Technical Documentation Manual

Mikrofill Ethos Series Technical Documentation Manual

Floor standing room sealed condensing boilers
Table of Contents

Advertisement

I N S P I R E D
E F F I C I E N C Y
C O N D E N S I N G
B O I L E R S
ETHO S RS 3 5 0 & RS 5 50 FLOOR STAND IN G R OOM SEALE D CON DE NSIN G BO IL E RS
TECHNICAL DOCUME NTATION
ISSUE 03/18 R ev . 02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ethos Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mikrofill Ethos Series

  • Page 1 I N S P I R E D E F F I C I E N C Y C O N D E N S I N G B O I L E R S ETHO S RS 3 5 0 & RS 5 50 FLOOR STAND IN G R OOM SEALE D CON DE NSIN G BO IL E RS TECHNICAL DOCUME NTATION ISSUE 03/18 R ev .
  • Page 3: Table Of Contents

    TA BLE O F C ON TE NTS Technical Data Boiler Module PCB Symbol Key Dimensions Switching On the Appliance Switching Off the Appliance Safety Guidelines Information Display Conditions DHW Operation General Guidelines Heating Operation Service Displaying Information General Restrictions Table Parameter List History Mode Description...
  • Page 4: Technical Data

    T EC HN I C AL D AT A GENERAL Dimensions (Height x Width x Depth) 1300 x 750 x 1100 1300 x 750 x 1500 ETHOS RS 350 ETHOS RS 550 Model Water Content of Appliance litre Weight (Empty) Flow / Return Connections DN50 PN16 Flange DN65 PN16 Flange...
  • Page 5: Dimensions

    D IMEN SIONS • All dimensions are in millimetres unless otherwise specified. • Depth dimensions are taken from the front to the rear of the casing and do not include the external pipework. • Height dimensions are taken from the bottom of the boiler and do not include the height of the supplied adjustable feet.
  • Page 6: Safety Guidelines

    SA FE T Y G UI D EL I N E S CONDITIONS Mikrofill Systems Ltd. shall not be liable for any damages caused by non-compliance with this manuals instructions. Only original parts must be used for service purposes. GENERAL GUIDELINES...
  • Page 7: Service

    03452 60 60 20. GENERAL RESTRICTIONS Mikrofill products should always be used, installed and maintained in accordance with the statutory requirements, specifications and standards applicable to these installations. Mikrofill cannot be held responsible for any losses or damage whether direct or consequential that have arisen as a result of incorrect or poor installation.
  • Page 8: Description

    DESC RI P T I O N GENERAL The Mikrofill ETHOS RS floor standing boilers are environmentally friendly gas fired heating boilers with a modulation range between approximately 10% and 100% of their maximum output. The appliances have low and CO emission, which satisfies the most stringent environmental requirements.
  • Page 9: Main Components

    D ESC RIPTIO N FRONT VIEW: REAR VIEW: TOP VIEW: MAIN COMPONENTS: Burner #00 Control Unit Burner #01 Control Unit Combustion Fan Control Fascia Electrical Connections Gas Valve Heat Exchanger and Burner Package Flap Valve Venturi REAR CONNECTIONS: Air Inlet Condense Outlet Flow Connection Gas Connection...
  • Page 10: Boiler Control

    DESC RI P T I O N BOILER CONTROL If there is a heat demand, and if all necessary conditions have been fulfilled and all safety devices are satisfied, the boiler will start. This heat requirement will arise if: • the flow temperature of the boiler is less than the required flow temperature. •...
  • Page 11: Delivery & Transport

    D EL I VERY & T RAN SPO R T DELIVERY The boiler is delivered fully assembled, tested and packed. • Check the boiler for damage upon receipt. • Check whether the items delivered are correct and in accordance with the items ordered. TRANSPORT The packing should only be removed after transportation.
  • Page 12: Installation

    INS TAL LA TI O N REGULATIONS The appliance should be installed by a competent installer in accordance with the applicable national and local standards, rules and regulations (please refer to pages 06 and 07 for safety guidelines). INSTALLATION GUIDELINES The following guidelines should be complied with;...
  • Page 13: Ventilation

    IN ST AL LA TION VENTILATION The ventilation of the installation room should conform to current gas regulations. GAS CONNECTION The gas connection is located on the rear of the appliance (see page 09). It should be installed by a competent installer in accordance with the applicable national standards.
  • Page 14: Internal Controls Breakdown (Main Pcb)

    INS TAL LA TI O N INTERNAL CONTROLS BREAKDOWN (MAIN PCB) 01 02 03 01 02 03 04 05 01 02 04 05 06 06 07 08 09 10 03 04 ▲ FIGURE 02. TOP VIEW OF MAIN PCB. • X00 Pin 01: Power to Main PCB •...
  • Page 15: Internal Controls Breakdown (Control Fascia)

    IN ST AL LA TION INTERNAL CONTROLS BREAKDOWN (CONTROL FASCIA) ▲ FIGURE 03. TOP VIEW OF CONTROL FASCIA. • X01 Pin 01: Control Fascia to Main PCB • X03 Pin 02: Communication with Master • X05 Pin 01: Alarm Output •...
  • Page 16: Controls And Options

    INS TAL LA TI O N CONTROLS AND OPTIONS The boiler features an automatic fully modulating control system and as such can be used as a ‘stand alone’ appliance. The standard controls include; • 0 - 10 V Input ready. •...
  • Page 17: Flue Connection

    IN ST AL LA TION FLUE CONNECTION The flue gas discharge outlet system should be installed by a competent installer according to applicable national and local standards and specifications. Care should also be taken to ensure compliance with the Clean Air Act. The boilers are suitable for the following flue system types: •...
  • Page 18: Flue Length

    INS TAL LA TI O N FLUE LENGTH Since the boiler is equipped with a ‘premix burner’ with a fan, an over pressure is created in the boiler. This over pressure is sufficient to overcome the resistance of the burner, the heat exchanger and the chimney. The back pressure on the boiler depends on: •...
  • Page 19: Condense Connections

    IN ST AL LA TION CONDENSE CONNECTIONS The boiler includes an anti syphon condense trap enabling the condense pipework to be taken directly to drain. The condense water is slightly acidic (pH 3.0 - 5.5) and should be run in a standard drain pipe material, e.g.
  • Page 20: Shut-Off Valves

    INS TAL LA TI O N SHUT-OFF VALVES It is recommended that manual valves should be installed between the flow and return connections to the installation. VALVES (BOILERS IN CASCADE ARRANGEMENT) To prevent water flow through non-firing boilers, and hence unnecessary heat loss, a spring loaded non-return valve may be installed on the return pipework external to the boiler.
  • Page 21: Water Pressure

    IN ST AL LA TION WATER PRESSURE At a maximum flow temperature of 90°C and with the nominal water flow that occurs at a ΔT of 20°K, the minimum operating pressure should be at least 1.5 bar. The operating pressure should be measured when the external pump is switched off.
  • Page 22: Water Hardness

    INS TAL LA TI O N WATER HARDNESS Water hardness levels are caused by dissolved minerals in the water and will vary geographically. The harder the water, the more likely that problems with precipitation (limescale deposits) will occur, causing permanent damage to the boiler and associated equipment.
  • Page 23: Boiler Module

    OP ER A TING INST RU C TIONS BOILER MODULE RESET RESET DHW Selection Heating Selection Multi-Function Reset Switch DHW Temperature Heating Temperature Power Switch PCB SYMBOL KEY - OpenTherm Connection - Heating Circuit Active - Information - Summer Mode - Wireless - Pump Active - Reset Required...
  • Page 24: Switching On The Appliance

    O P E RAT I NG I N ST R UC T I ON S WARNING: • The appliance should be installed by a competent installer. • These operating instructions should be closely followed. • If the cause of any fault cannot be determined, please contact the technical department. •...
  • Page 25: Information Display

    OP ER A TING INST RU C TIONS INFORMATION DISPLAY: RESET RESET DHW OPERATION • DHW Mode can be enabled or disabled by using the button. • The DHW setpoint can be increased or decreased by using the buttons. HEATING OPERATION •...
  • Page 26: History Mode

    O P E RAT I NG I N ST R UC T I ON S HISTORY MODE • To access history mode, press and hold until the display shows ‘Bu 0’. • Press the button and the display will flash ‘Hi 0’. •...
  • Page 27: Possible Error Codes Continued

    OP ER A TING INST RU C TIONS POSSIBLE ERROR CODES continued. ERROR CODE DESCRIPTION RESOLUTION Return temperature sensor short The return temperature sensor is registering a short circuit. Check the circuit. connection to the sensor and replace the sensor if necessary. Return temperature sensor open The return temperature sensor is registering an open circuit.
  • Page 28: Commissioning

    CO M M I S S I ON I N G GENERAL The commissioning should only be carried out by qualified personnel. The guarantee may be void if this is not adhered to. Before operating the appliance, the following should be done: •...
  • Page 29: Maximum Load Adjustment

    C OM MISS IONING MAXIMUM LOAD ADJUSTMENT Press and hold the button for three seconds until the below display appears, the boiler will then start to operate at minimum load. To adjust to maximum rate, press and hold until the below display appears, the boiler will then start to operate at maximum load.
  • Page 30: Setting The Co Value For The Ethos Rs Range

    CO M M I S S I ON I N G SETTING THE CO VALUE FOR THE ETHOS RS RANGE • Any adjustments should only be carried out by competent persons. • After adjustment of the gas valve the adjusters must be resealed. There is a setting screw on the gas valve with which the CO value can be set at maximum load.
  • Page 31: Conversion From Natural Gas To Propane

    C OM MISS IONING CONVERSION FROM NATURAL GAS TO PROPANE For natural gas to propane conversion, it is only necessary to change the gas volume by altering the CO values as described on pages 28 - 30. C A SC A DE S ET- U P AUTO DETECTION MODE Cascade structure will need to be auto detected prior to cascading the boilers.
  • Page 32: Cascade Test Mode

    CA S C A DE S E T - UP CASCADE TEST MODE • Press and hold the buttons together for three seconds. • This will send a request to the master boiler to fire all slave boilers. • This can be increased to 100% by pressing the button until the display below is shown.
  • Page 33: Maintenance

    The frequency of maintenance will depend upon the installation condition and usage, but should still be carried out at least annually. Mikrofill Systems Ltd. does not accept liability resulting from the use of unauthorised components for the repair and maintenance of appliances not in the companies recommendations and specifications.
  • Page 34: Removal Of Gas Valve And Venturi

    M AI N T EN A N C E REMOVAL OF GAS VALVE AND VENTURI • Isolate the gas and electrical supplies to the boiler. • Remove the four screws from the flange on the rear of the gas valve ( •...
  • Page 35: Removal Of Fan And Burner Assembly

    MA INT ENA NCE REMOVAL OF FAN AND BURNER ASSEMBLY • Isolate the gas and electrical supplies to the boiler. • Remove the caps from the ignition electrode and ionisation probe. • Remove the two electrical connections from the fan. •...
  • Page 36: Setting / Checking Of Electrode And Probe Gaps

    M AI N T EN A N C E SETTING / CHECKING OF IGNITION ELECTRODE AND IONISATION PROBE GAPS In addition to the annual maintenance, please ensure the following is carried out: • Isolate the gas and electrical supplies to the boiler. •...
  • Page 37: Component List

    C OM PON ENT L IS T Any components within the ETHOS RS 350 - RS 550 that may require replacing have been listed in this section, along with their respective part codes. If any part needs replacing which is not listed here, please contact our technical department on 03452 60 60 20 for assistance.
  • Page 38: Core Components

    CO M P O NE N T L I S T CORE COMPONENTS 38 TEC HN ICAL DOCUM ENTA TION...
  • Page 39: Flue Components

    C OM PON ENT L IS T FLUE COMPONENTS ▲ FIGURE 10. EXPLODED DRAWING DETAILING THE FLUE COMPONENTS OF THE ETHOS RS 350 - RS 550. “(PART CODE) PART NAME”: (FRS350001) AIR INLET TUBE (FRS350003) FLUE CAP (Ø 110mm) (ETHOS RS 350) (Ø...
  • Page 40: Conversion Formulae & Factors

    CO N VE RS I ON F O R M U L A E & F A CT ORS FORMULAE 20.9 - measured O measured CO x 20.9 x 11.7 = 20.9 - 20.9 11.7 11.7% CO is the maximum CO percentage that is generated by stoichiometric burning of G20 natural gas (H-gas).
  • Page 41 C O N V E R S I ON FORM UL A E & FA C TO R S FOR NON-CONDENSING BOILERS: 0.339 0.377 nb = 90 - + 0.008 x ΔT no = 100 - + 0.009 x ΔT FOR CONDENSING BOILERS: As a result of condensation, the efficiency at the lower value increases.
  • Page 42: Notes

    NOT ES 42 TEC HN ICAL DOCUM ENTA TION...
  • Page 43 ISO 9001 Registered Quality Management...
  • Page 44 Mikrofill Systems Ltd. 11 Merse Road, North Moons Moat, Redditch, Worcestershire B98 9HL , U K +44 (0)3452 60 60 20 +44 (0)3452 60 60 21 info@mikrofill.com www.mikrofill.com...

This manual is also suitable for:

Ethos rs 350Ethos rs 550

Table of Contents