Adjustment
12
Limiting the knee lever stroke
.05.15
12 - 17
Requirement
When the knee lever 3 is pushed fully, the presser foot should rise approximately 8 mm
from the needle plate.
109-046
Fig. 12 - 16
Adjust screw 1 (nut 2) in accordance with the requirement.
3
1
109-093
2