Jumpers; Power Supply Voltage (Jp: 99, 100, 101, 102, 103); Level-Shifter Direction Control: (Jp1 - Jp3, Jp27 - Jp32, Jp59, Jp61 - Jp65 And Jp86 - Jp88) - Fujitsu PB-91469G-LS-256BGA User Manual

Probe cable
Table of Contents

Advertisement

3 Jumpers

This chapter describes all jumpers that can be modified on the probe. The default setting is
shown with a grey shaded area. All jumpers are named directly on the board, so it is very
easy to set the jumpers according to the features.

3.1 Power Supply Voltage (JP: 99, 100, 101, 102, 103)

3V3 and 5V are the supply voltages for the Level shifters. The Jumpers JP99 and JP101 in
conjunction with S1 and S2, allow to use an externally power supply for the Level shifters. In
that case, take care of the input-voltage. Neither a voltage regulation nor an over-voltage-
protection does exist for an external power-supply. The default setting is supplying the level
shifters with UVCC3 and UVCC5 directly.
Jumper
JP99 (5V
supply)
JP101 (3V3
supply)
ON (closed)
JP102 (UVCC5
> 5V_T)
OFF (open)
ON (closed)
JP103 (UVCC3
> 3V3)
OFF (open)
JP100
3.2 Level-shifter Direction Control: (JP1 – JP3, JP27 – JP32, JP59,
JP61 – JP65 and JP86 – JP88)
Jumper
JP1 (D0-D7)
direction control
LV1 /1DIR
UG-910022-13
PB-91469G-LS-256BGA V12
Chapter 3 Jumpers
Setting
Description
1 - 2
The emulator site of the level shifters (B-site, 5V) is
supplied by 5V_T.
2 - 3
The emulator site of the level shifters (B-site, 5V) is
supplied by external power-supply from S1.
The target site of the level shifters (A-site, 3V3) is
1 - 2
supplied by VDD35.
2 - 3
The target site of the level shifters (A-site, 3V3) is
supplied by external power-supply from S2.
5V_T (target) is connected to UVCC5 of the
emulator MB2198-300. (see also JP100)
5V_T (target) is not connected to UVCC5 of the
emulator MB2198-300. (see also JP100)
3V3 (target) is connected to UVCC3 of MB2198-
300. (see also JP100)
3V3 (target) is not connected to UVCC3 of
MB2198-300. (see also JP100)
1 – 2
VDD35 is connected to 3V3
2 – 3
VDD35 is connected to 5V_T
Open
Setting
Description
1DIR connected to DIR -> the direction of LV1/1
1 – 2
1A<>1B is selectable
1DIR connected to GND -> LV1/1 direction B/A
2 – 3
(MB2198-300 to target)
- 10 -
© Fujitsu Microelectronics Europe GmbH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mb91v460 series