13. MAINTENANCE
We recommend replacing the smoke capsule every 5
years using only the original replacement.
14. INDICATE THE INSTALLATION
In accordance with local laws, it may be
mandatory to report the presence inside a
room of one or more security smoke
systems. Apply the warning label near the
normal access point to the room.
15. NOTIFICATION TO THE AUTHORITIES
In accordance with local laws, it may be mandatory to
notify the competent authorities the installation of one or
more security smoke systems.
16. WARRANTY
SMARTEK s.r.l. It guarantees its products against all
manufacturing defects for a period of 30 months from the
production date shown on the label.
17. RECOMMENDATIONS
Install in a dry place, under 70% of
relative humidity. In installations in
more humid environments do not
remove the adhesive that protects the
smoke outlet.
The device must be handled by
qualified technician.
Do not place any objects on the
smoke exit hole for a distance of at
least 1,5 meters.
Before leaving, ventilate the rooms
thoroughly after the smoke has been
delivered.
18. LIMITATION OF LIABILITY
SMARTEK srl is not responsible for any use of the product
that does not conform to its recommended use or for
installations that do not comply with the indicated
guidelines.
SMARTEK srl can not be held responsible for thefts
suffered in environments where the NUBI product is
installed, regardless of whether or not it has been
activated.
SMARTEK srl can not be held responsible for any direct or
indirect damage caused by the supply of smoke.
Installation manual NUBI F1
19 TECHNICAL SPECIFICATIONS
Power supply
Consumption
Size
Saturable volume
Weight
Smoke average delivery time
Operating temperature
Storage temperature
Maximum relative humidity
Inputs
Outputs
20 WIRING SMOKE CAPSULE
At the end of installation the smoke capsule mus be wired
to the main connector screw terminal 3 and 4. The smoke
capsule has not polarity but the two white wires must be
wired together, the same for coloured wires, as showed in
the picture.
IMPORTANT: When the smoke supply will start, it will
continue until the capsule will be completely exhausted.
www.smarteksrl.it
12VDC ±15%
10mA
9cm x 14cm x 8cm
100m
3
760g
25sec
From 0°C to +45°C
From -20°C to +55°C
70%
SI – System state
ALL – Alrm
CS – Immediate action
24H – Tamper
OC – Alarme
OUT – Empty capsule
Pag. 3 of 3