Thank you to purchase of NUBI 4.0, the intelligent smoke
machine able to be connected to any burglar alarm system
in new or existing systems. Thanks to the integrated
intelligence and the infrared motion sensor, NUBI 4.0
drastically reduces the activations due to false alarms. The
device is 12 V DC powered, usually supplied by the alarm
control panel, the current consumption is only 10 mA.
NUBI efficiently protects volumes up to 100 m
generated by NUBI 4.0 is based on incense and does not
produce toxic atmosphere as tested according to the TLV-
STEL directive EU 2017/164 and ACGIH. After use the
room must be ventilated before staying there.
2. INSTALLATION
NUBI 4.0 can be easily installed on the
wall or even in a corner at a height
between 150 and 300 cm.
A single upper screw allows disassembly between the
base and the top cover.
3. MOTHERBOARD
Main elements placed on
motherboard are:
Keep out of reach of children, away from open and dry flames.
Installation manual NUBI F1
3
. The smoke
1)
Main connector
2)
Integrated passive
infrared connector.
3)
Diagnostic LEDs
4)
DIP Switches
5)
Walk test button
6)
Tamper switch
7)
Reserved connector.
NOTICE: Always connect the supplied 33K resistance to
+12V or GND to the SI, ALL and CS inputs, depending on
the polarity chosen.
With alarm panel outputs active at GND
With alarm panel outputs active at +12V
Some alarm panel outputs active at GND, others at
www.smarteksrl.it
4. Main connector
1
+12V
Power supply + 12VDC
2
GND
Power supply GND
3
CF1
Smoke capsule
4
CF2
5
SI
System state (input)
6
ALL
Alarm (input)
7
OUT
Empty capsule (output)
8
OC
Alarm (output)
9
CS
Immediate action (input)
10
GND
GND
11
24H
Tamper switch
12 24H
5. INPUTS POLARITY
GND
Pag. 1 of 3

Advertisement

loading

Summary of Contents for Smartek NUBI 4.0 F1

  • Page 1 1. NUBI 4.0 F1 4. Main connector Thank you to purchase of NUBI 4.0, the intelligent smoke +12V Power supply + 12VDC machine able to be connected to any burglar alarm system Power supply GND in new or existing systems. Thanks to the integrated intelligence and the infrared motion sensor, NUBI 4.0...
  • Page 2 6. DIP SWITCHES 9. WALK TEST Press the Walk Test button to activate the diagnostic DIP ON function for 10 minutes to turn on the blue LED every time Tamper disabled Tamper active the passive infrared detects movement. This allows to position the device to obtain the maximum coverage of the Not used Not used...
  • Page 3 18. LIMITATION OF LIABILITY SMARTEK srl is not responsible for any use of the product that does not conform to its recommended use or for installations that do not comply with the indicated guidelines.