READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Failure to comply with instructions could result in person injury or property damage.
Page 3
GENERAL SAFETY INFORMATION CONTINUED Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause motor humming noise. When this product is no longer being operated, please remove the product to prevent the possibility of falling.
DESCRIPTION This Panasonic ventilating fan model is listed by UL under UL file No. E78414. This product uses a sirocco fan driven by a capacitor motor. It also incorporates a thermal-cut off for safety. The trim ring is a spring-loaded, quick remove type.
DIMENSIONS 12 3/4 (324) 1/2 (12) 7 1/2 (190) 16 5/8 (423) Lamp cover Trim ring Junction box Fan body Adaptor Suspension bracket Blower unit Motor Damper LED lamp Bracket cover WIRING DIAGRAM Fan body Junction box White White Neutral Power Supply LED lamp Black...
INSTALLATION (BETWEEN JOISTS MOUNTING) Unit: inches (mm) Suspension bracket Suspension bracket Adaptor Tape Damper Adaptor Bracket cover Screw (ST4.2X6) Fig. 1 Please follow the installation steps as below: 1. Insert the suspension brackets into the fan body from each side of the bracket cover. (Fig. 1) Long hole Suspension bracket...
Page 7
INSTALLATION (BETWEEN JOISTS MOUNTING) CONTINUED 5. Hang the fan body down from the four long screws, 2-screws and adjust the suspension brackets if necessary. (ST4.2X6) 2-screws Then, tighten the fou r long screws up . And that, fix (ST4.2X18) the other four long screws (ST4.2X20) to other holes. Make sure the fan body is level and square with the joists.
Page 8
INSTALLATION (BETWEEN JOISTS MOUNTING) CONTINUED 10. Finish ceiling work. A circle ceiling hole ( 6 1/2 inches (165mm) dia.) should be cut. And make sure there will be a gap ( >1/8 inches (3.2mm )) between bottom of 6 1/2 (165) Dia. fan body and ceiling.
INSTALLATION (BETWEEN JOISTS MOUNTING) CONTINUED 13. Lock the lamp cover. 2-Slots 2-Mounting Make sure the lamp cover is locked securely. ① springs ② Otherwise the lamp cover may drop. Trim ring 14. Insert the mounting springs into the slot as shown in the figure and attach the trim ring to the fan Fig.
MAINTENANCE (CLEANING) CONTINUED 3. Dry the trim ring after cleaning. 4. Remove dust and dirt from fan body using a vacuum Vacuum cleaner cleaner. (Fig. 13) Fig. 13 (Fig. 14) 6. Replace the trim ring. Gloves Fig. 14 MAINTENANCE (REPLACEMENT OF LED LAMP) Disconnect power source before working on unit.
Fans installed with existing ducts may not achieve their rated air flow. SPECIFICATIONS Lamp 1378 20.5 13.0 FV-08VRE1 10.0(4.5) 20.5 1378 13.0 HVI Certified performance based on HVI Procedures 915, 916 and 920. LIST OF COMPATIBLE DIMMERS (NOT SUPPLIED)