CONNECTOR CN1
1) F
Phase 95-255 Vac
2) N
Neutral 95-255 Vac
3)
Ground
230Vac
CONNECTOR CN2
4) AP M1
M1 motor connection
5) CH M1
M1 motor connection
6) AP M2
M2 motor connection
7) CH M2
M2 motor connection
Motor M2 starts first during closing
8) ELS
Electric lock output connection
9) ELS
Electric lock output connection
At the opening command, it turns on for 1 sec. Before activating door M1
10) LAMP
Flasher connection max. 25W 24Vdc
11) COM OUT
Common link Blinking light gate open/courtesy light
12) SP LC
Gate open indicator / courtesy light max 3Watt 24Vdc
for higher power levels, it is recommended to connected a relay sized for the applied load to
this output
M
M
RG58