Page 1
User MANUAL Imaging Tables CFPMFXH CFPMFXH integrated headrest top rectangular top CFPM100 CFPM100 integrated headrest top rectangular top CFPM300 CFPM300 integrated headrest top rectangular top CFPM400 CFPM400 integrated headrest top rectangular top CFPM301 CFPM301 integrated headrest top rectangular top CFPMB301...
PRoDUCT Use DesCRIPTIon / IMPoRTanT saFeTy InsTRUCTIons PRoDUCT Use DesCRIPTIon Oakworks® Imaging Tables are radiographic tables intended for use with mobile or compact stationary C-arm Imaging Systems. It is ideally suited for pain management imaging and therapeutic procedures. These tables are suitable to use for diagnostic x-ray imaging and imaging during therapeutic procedures such as spinal injections, vertebroplasty procedures and other pain management procedures.
Grounding reliability can only be achieved when this equipment is connected to an equivalent 3 prong receptacle marked “Hospital Only” or “Hospital Grade”. Oakworks medical tables are designed and built to provide many years of dependable service. Please follow local regulations and laws when disposing of the electrical components used in this table.
Page 6
IMPoRTanT saFeTy InsTRUCTIons WaRnInG To reduce the risk of burns, fire, electric shock or injury to persons: 1. Unplug this furnishing from the electrical outlet before cleaning. 2. Unplug from outlet before adding or removing parts. 3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water.
PRoDUCT DesCRIPTIon CFPMFXH 24” X 80” ReCTanGULaR ToP Carbon Fiber Integrated Headrest Top with removable Table Top Pad Hand rail Integrated Face rest with Crescent Face Pad Locking Casters Standard SpecificationS optionS fixed Height 37” (91cm) 5” (13cm) Locking casters choice of tabletop: custom heights: 31”-37”...
PRoDUCT DesCRIPTIon CFPM100 24” X 80” ReCTanGULaR ToP Carbon Fiber Integrated Headrest Top with removable Table Top Pad Hand rail Integrated electronic Face rest Lift Tower with Crescent Face Pad emergency stop Locking Casters Standard SpecificationS optionS Height Motion powered 22”-40” (56-102cm) 5”...
PRoDUCT DesCRIPTIon CFPM300 24” X 80” ReCTanGULaR ToP Carbon Fiber Integrated Headrest Top with removable Table Top Pad Hand rail electronic Lift Tower Integrated Face rest with Crescent emergency Face Pad stop Locking Casters Standard SpecificationS optionS Motion 1 powered 26”-44” (66-112cm) Height range 5”...
PRoDUCT DesCRIPTIon CFPM400 24” X 80” ReCTanGULaR ToP Carbon Fiber Integrated Headrest Top with removable Table Top Pad Hand rail electronic Lift Tower Integrated Face rest with Crescent emergency Face Pad stop Locking Casters Standard SpecificationS optionS Motion 1 powered 26”-44” (66-112cm) Height range 5”...
PRoDUCT DesCRIPTIon CFPM301 24” X 80” ReCTanGULaR ToP Carbon Fiber Integrated Headrest Top with removable Table Top Pad Hand rail electronic Lift Tower Integrated Face rest with Crescent emergency Face Pad stop Locking Casters Standard SpecificationS optionS Motion 1 powered 25”-43” (64-109cm) Height range 5”...
PRoDUCT DesCRIPTIon CFPM401 24” X 80” ReCTanGULaR ToP Carbon Fiber Integrated Headrest Top with removable Table Top Pad Hand rail electronic Lift Tower Integrated Face rest with Crescent emergency Face Pad stop Locking Casters Standard SpecificationS optionS Motion 1 powered 26”-44” (66-112cm) Height range 5”...
PRoDUCT DesCRIPTIon CFLU401 - Lithotripsy/Urology Top short extension Carbon Fiber Top with removable Table Top Pad T-rail Hand rail (along each side) (under end) end extension emergency stop Locking Casters Standard SpecificationS Motion 1 powered 27”-45” (66-112cm) Height range Urology Bag Hoop clips onto t-rails (bag not included) Motion 2 powered +15°/-12°...
InsTaLLaTIon The Imaging tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (see Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible.
DIReCTIons FoR Use FooT ConTRoL - one MoTIon Used to raise and lower the height of the table. FooT ConTRoL - THRee MoTIon Used to control table Vertical Height, Trendelenburg, Lateral Tilt OR Vertical Height, Trendelenburg, Longitudinal Motion. Control functions dependent upon table’s features. FooT ConTRoL - FoUR MoTIon Used to control table Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Tilt OR Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Motion.
Page 19
DIReCTIons FoR Use HanD ConTRoL - THRee MoTIon Used to control table Vertical Height, Trendelenburg, Lateral Tilt OR Vertical Height, Trendelenburg, Longitudinal Motion. Control functions dependent upon table’s features. HanD ConTRoL - FoUR MoTIon Used to control table Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Tilt OR Vertical Height, Trendelenburg, Longitudinal Motion, Lateral Motion.Control functions dependent upon table’s features.
DIReCTIons FoR Use BUBBLe LeVeLs Bubble levels are installed on the handle end of the table to aid the operator to determine the horizontal plane. anGLe InDICaToR Standard on CFLU401, CFUR401 and CFUR301 Tables. Optional on all other Imaging Tables. To use angle indicator, simply press “on/off”...
DIReCTIons FoR Use ReMoVe / RePLaCe THe TaBLe ToP PaD CaUTIon Make sure the top is not in motion when removing / replacing the table top pad. Remove Table Pad by pulling flaps at the ends & sides of the table until the hook and loop fastener becomes unanchored.
DIReCTIons FoR Use LoCkInG CasTeRs Use All four casters should be locked at all times during use with a patient. LoCkInG THe CasTeRs Un-LoCkInG THe CasTeRs 1. Place your shoe on the end of the casters locking tab. 1. Place your shoe on top of the casters locking tab. 2.
DIReCTIons FoR Use WeIGHT CaPaCITy & PaTIenT Use The o table top is rated at 500 lb. (227 kg) load evenly distributed. (Bariatric table is rated ® CaUTIon akworks at 750 lbs. (340 kg)) To minimize any risk to the patient, do not allow the patient to sit on the face rest area beyond the warning line on the table top.
DIReCTIons FoR Use LaTeRaL eXTensIons - LITHoTRIPsy/URoLoGy & URoLoGy ToPs CaUTIon Do not sit on any extensions. Weight Limit: 200 lbs. / 91 kg. There are four lateral extensions for the Lithotripsy table. (2 - 8” x 11”, 1 - 8” x 14” and 1 - 8” x 24”). 8”...
DIReCTIons FoR Use enD eXTensIons - LITHoTRIPsy/URoLoGy & URoLoGy ToPs CaUTIon Do not sit on any extensions. Weight Limit: 200 lbs. / 91 kg. There are extensions which can be inserted on either end of the table. (1) - 23” x 28” (58 x 71cm) and (1) - 23” x 16”...
DIReCTIons FoR Use CaRBon FIBeR aRM BoaRD (aCCessoRy) Do not place undue weight or downward pressure on the Carbon Fiber Arm Board. It is a posi- CaUTIon tioning device for the arms and should not be used as leverage to get on or off the table. Injury can occur.
DIReCTIons FoR Use sPIne PosITIonInG sysTeM II (aCCessoRy) For directions on the use of the Spine Positioning System, see publication “Spine Positioning System” Part number MMMMNUP0003 Contoured torso suPPort Pad CresCent FaCe rest Pad radioluCent Frame With adjustable FaCe rest Contoured torso Wedge 8”...
MAINTENANCE • No specific maintenance tasks are required. • Oakworks medical tables/chairs are designed and built to provide many years of dependable service. Please follow local regulations and laws when disposing of the electrical components used in this chair. For all Customer Service related problems refer to the Service Manual •...
MoDeL nUMBeR & seRIaL nUMBeR MoDeL & seRIaL nUMBeRs Serial Number Model Number Imaging Table Power Rating 120 V 60 Hz 8.2 A Class 1 Equipment Duty Cycle: MAX 2 minutes ON 16796025 FL40IF222684MGTTZZF8 Ser#: FL4563563 18 minutes OFF CFPM400 IF 22 x 26-44 x 84 MG/TT/F8 TTCoal 01/04/2013 Order#:654321 Notes: Sample Product Label European Authorized...
& Transport -20° (-29°C) to 135° (57°C) 20% to 95% rH 98 to 105 kPa eLeCTRICaL sPeCIFICaTIons CFPM400, CFPM401, CFPM301, CFLU401, CFUr401 & CFUr301 CFPM100 Tables only Tables Designed for: NorTH AMerICA eUroPe NorTH AMerICA eUroPe Input service (All electric...
sPeCIFICaTIons Guidance and Manufacturer’s Declaration - electromagnetic emissions all equipment and systems (except CFPMFXH) The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. emissions Test Compliance electromagnetic environment - guidance...
sPeCIFICaTIons Guidance and Manufacturer’s Declaration - Immunity all equipment and systems The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. electromagnetic Immunity Test IeC 60601 test level...
sPeCIFICaTIons Guidance and Manufacturer’s Declaration - Immunity equipment and systems that are noT life-supporting The table is intended for use in the electromagnetic environment specified below. The customer or the user of the table should assure that it is used in such an environment. electromagnetic Immunity Test IeC 60601 test level...
Need help?
Do you have a question about the CFPM100 and is the answer not in the manual?
Questions and answers