Archgard Optima 32 Users Installation Operation & Maintenance Manual

Gas fired vented room heater (direct vent)

Advertisement

f i r e - p a r t s . c o m
WARNING:
If the information in this manual is
not followed exactly, fire or explosion may result
causing property damage, personal injury or loss
of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance.
· Do not touch any electrical switch; do not use
any phone in your building.
· Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
· If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Installer: Please leave this manual with the appliance owner for future reference
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
OPTIMA 32
Gas Fired Vented Room
Heater (Direct Vent)
For use with natural gas or
propane
U
SERS
I
NSTALLATION
O
PERATION &
M
AINTENANCE
M
ANUAL
This appliance may be installed in an
aftermarket permanently located,
manufactured home (USA only or mo-
bile home, where not prohibited by lo-
cal codes.
This appliance is only for use with the
type of gas indicated on the rating
plate. This appliance is not convertible
for use with other gases, unless a certi-
fied kit is used.
C
U
Master Contract: 214018
200-0100
04 Oct 02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Optima 32 and is the answer not in the manual?

Questions and answers

Summary of Contents for Archgard Optima 32

  • Page 1 OPTIMA 32 Gas Fired Vented Room Heater (Direct Vent) For use with natural gas or propane SERS NSTALLATION f i r e - p a r t s . c o m PERATION & AINTENANCE WARNING: If the information in this manual is...
  • Page 2: Table Of Contents

    CONTENTS Introduction General Information Appliance Description Dimensions and Clearances Installation Instructions 8 - 13 Operation Instructions 14 - 15 Maintenance Trouble Shooting Instructions 17 - 18 Wiring Diagrams Servicing 20 - 22 Replacement Parts Warranty f i r e - p a r t s . c o m CAUTION Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
  • Page 3: Introduction

    INTRODUCTION Congratulations for choosing an Archgard fireplace. The Optima 32 is one of the most advanced Direct Vent fireplace insert heaters available today. It is solidly designed using the latest technology and manufactured to the highest quality. It is our aim to provide you an appliance with many trouble free years of reliable service.
  • Page 4: General Information

    - ANSI Z21.88a-2000 /CSA 2.33a-M00, Vented Gas Fireplace Heaters, - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance. INSTALLATION CODES This appliance must be installed by a qualified gas appliance installer.
  • Page 5: Appliance Description

    PTIMA 32 APPLIANCE DESCRIPTION TOP VIEW ON-OFF SWITCH POWER CORD (AND GAS INLET SIDE) INLET FLUE f i r e - p a r t s . c o m CONNECTION OUTLET FLUE CONNECTION FRONT VIEW TOP GRILL GLASS DOOR BRICK PANELS BOTTOM...
  • Page 6: Dimensions And Clearances

    PTIMA 32 DIMENSIONS AND CLEARANCES APPLIANCE DIMENSIONS A 25 5/8” (651 mm) B 16” (406 mm) 19 7/8” (505 mm) C 14” (356 mm) 3 3/4” (93 mm) D 14 1/8” (359 mm) f i r e - p a r t s . c o m 1 1/4”...
  • Page 7 PTIMA 32 DIMENSIONS AND CLEARANCES Cont... f i r e - p a r t s . c o m...
  • Page 8: Installation Instructions

    34,000 BTU/hr (9,800 watts) ABOVE 4500 ft. (1372 m) 34,000 BTU/hr (9,800 watts) less 4% per 1000 ft. (305m) Please contact your Archgard dealer or distributor for the appropriate orifice size above 4500’. Propane Pressure Settings: The inlet supply or line pressure must be a minimum of 11 1/2” wc (2.9 kPa) and a maximum of 14”...
  • Page 9 All gas connections must be checked for gas leaks. ELECTRICAL CONNECTIONS The Optima 32 comes complete with an electrical cord and plug already installed. If you require to run an electrical lead to the appliance instead, follow the instructions listed below.
  • Page 10 Only use the approved vertical termination caps with this appliance Archgard part number TK-32 “Dura-vent” part # 980 (cap), 923GK (adaptor with flashing) or 991 (high wind cap) Periodically check that the venting system is not restricted or blocked (every 12 months) WARNING: Operation of this heater when not connected to a properly installed and f i r e - p a r t s .
  • Page 11 PTIMA 32 INSTALLATION INSTRUCTIONS Cont... SWITCH MOUNTING AND WIRING ON-OFF SWITCH: The on-off switch is located in the side trim. The wire must be run along the frame and clipped together. Attach to valve terminals as shown on page 15. GLASS DOOR WARNING: THE OPTIONAL BAY DOOR IS A DECORATIVE ACCESSORY ONLY.
  • Page 12 PTIMA 32 INSTALLATION INSTRUCTIONS Cont... PLACEMENT OF LOGS AND BRANCH Locate the rear log on the locator pins and then the front logs on it’s pins. The branch fits over top as shown. It is locked into place with a pin on the Left Front Log and sits on the edge of the knot hole in the rear log.
  • Page 13 PTIMA 32 INSTALLATION INSTRUCTIONS Cont... OPTIONAL BAY DOOR CONVERSION WARNING: THE OPTIONAL BAY DOOR IS A DECORATIVE OPTION ONLY AND IS MANUFACTURED WITH TEMPERED GLASS. THIS UNIT MUST NOT BE OPERATED WITHOUT THE FLAT CERAMIC DOOR SECURED IN PLACE, BEHIND IT. NOTE: Ensure that the fireplace is turned off and cool, disconnect the power to the unit.
  • Page 14: Operation Instructions

    PTIMA 32 OPERATION INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING INITIAL OPERATION • Check that the appliance is properly vented and connected to the gas supply. • Check that the logs and branches are properly placed. • Check that all external parts, such as grills, door and faceplate are properly attached and fastened.
  • Page 15 PTIMA 32 OPERATION INSTRUCTIONS Cont.. MILLI-VOLT VALVE START-UP PROCEDURE Set the thermostat, if present, to the lowest level. Press slightly and turn the control knob clockwise to the OFF position and wait 5 minutes; thus allowing any gases to escape which may have accumulated in the combustion chamber. Note: LP gases do not vent upward.
  • Page 16: Maintenance

    PTIMA 32 MAINTENANCE CAUTION : Do not conduct maintenance on the appliance while it is operating or while it is still hot. CLEANING THE APPLIANCE The exterior painted surfaces, glass and gold trims may be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner.
  • Page 17: Trouble Shooting Instructions

    PTIMA 32 TROUBLE SHOOTING Please check to make sure the instructions are followed exactly before attempting trouble shooting of the appliance. WARNING: Trouble shooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician. SYMPTOM ACTION Pilot will not light after...
  • Page 18 PTIMA 32 TROUBLE SHOOTING Cont... SYMPTOM ACTION The main burner does not 3. Check to make sure the thermostat is set high enough to turn turn on with the pilot lit. on the appliance. Cont... 4. Check that the remote switch or the thermostat is turned on. 5.
  • Page 19: Wiring Diagrams

    PTIMA 32 WIRING DIAGRAMS CONVECTION BLOWER SPEED CONTROL 110F (43ºC) N.O. THERMAL SNAP SWITCH LINE CONVECTION BLOWER 120 VAC NEUTRAL ELECTRICAL GROUND f i r e - p a r t s . c o m AUTOMATIC VALVE SPARK ELECTRODE OPTIONAL THERMOSTAT PILOT BURNER...
  • Page 20: Servicing

    SERVICING SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the Archgard authorized dealer were you purchased the appliance from and provide him with details of the problem together with the initial installation information (from the back of this manual).
  • Page 21 PTIMA 32 SERVICING Cont... CHANGING MAIN BURNER ORIFICE • Remove the glass door, log set, coals (embers) and the brick panel set. • Unscrew the 2 screws holding the left burner log rest shield between the burner tubes and remove the shield. •...
  • Page 22 In the event your glass cracks or breaks, it must be replaced by the exact same size and mate- rial. The glass is made from high temperature ceramic material. See replacement parts list and contact your nearest Archgard dealer. •...
  • Page 23 PTIMA 32 Disassembly picture step 1 Remove the “H” burner from the tray by first removing the wing nut and washer (located under the firebox) holding the primary air sleeve as- sembly on the end of the burner feed tube. STEP 2 f i r e - p a r t s .
  • Page 24: Replacement Parts

    PTIMA 32 Replacement parts list for OPTIMA 32 DIRECT VENT INSERT PART NUMBER DESCRIPTION Owners manual ODVI-32 200-0100 300-0034 Door latch 301-0068 Cap orifice ( #35 DMS) natural gas 301-0068 Cap orifice ( #50 DMS) Propane gas 305-0013 Speed control KBMC-13BV c/w knob...
  • Page 25: The Appliance

    Place of Purchase Date of Purchase Problem Description NOTE: Warranty may be void if work is carried out by unqualified personnel. Only original Archgard parts may be used. Please consult your Archgard representative if in doubt. OBTAINING WARRANTY SERVICE: To obtain warranty service, the consumer shall return the defective part to the original selling dealer transportation prepaid, along with the serial number of the appliance and proof of purchase.
  • Page 26 PTIMA 32 Postage WARRANTY REGISTRATION ARCHGARD INDUSTRIES LTD. 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE f i r e - p a r t s . c o m FOLD DOWN AT LINE & TAPE CLOSED...