Fault Diagnosis Guide

Fault
Not Cooling
The power is on but not
cooling
Water leakage
Slow water flow
No water dispenses from the
taps
Drainage waste blocked
In the event of any other breakdown, please call your service engineer.

Electrical Diagram

Fuse
Possible Cause
The compressor is not running
The thermostat is set too high
The pipes or connections are
leaking
The filter is blocked
Water inlet valve(s) closed
or other blockage
Debris has blocked up the
waste system
Cold Thermostat
Compressor
Suggested Action
Check the power is switched
on
Reduce the thermostat
temperature setting
Switch off power turn off water
and call your service engineer
Change the filter
Open and/or reset the water
inlet valve(s) and/or check
water supply pipe
Clear the obstruction