Installation continued
5. Avoid tilting the machine during installation.
If the machine has been tilted excessively for
more than a few minutes during or before
installation, leave to stand for approximately
one hour before switching on.
6. Allow an air gap of at 100mm each side
and at the front of the machine.
7. Once positioned and levelled remove the
Front panel.
8. Unpack the swan-neck tap, fasten to the sink
top and connect to the water pipework. If

Water Connection

1. Connect the inlet water supply to the 3/4"
threaded connection at the rear. (Fit a Pressure
Reducing Valve to regulate the water pressure
as required. Max 3.5 bar) Ensure a stop tap
valve for the water is easily accessible. We
also recommend the use of a water-block and
non-return valve to be fitted.
2. We recommend that a filter is also fitted to
ensure water of the highest quality. A mounting
bracket is provided inside the cabinet. Always
pre-flush any filter before fitting.
3. Switch on the water and check the water
tightness of all connections and fittings.
4. Open both the swan-neck and bubbler tap
necessary remove the sink top to carry this out.
(See page 3)
9. Install/connect the waste water system as
selected. Do not use the fountain without any
waste system being fitted to the open end of
the waste fitting.
10. An access port hole for services is
provided on the rear of the cabinet and there is
a closed rubber grommet pre-fitted which can
be opened to protect the cabinet and pipe
where it passes through the access port hole.
IMPORTANT!
ALWAYS ENSURE SECURITY CLIPS
ARE USED ON ALL WATER AND
CO2 CONNECTIONS.
to vent the system until the water dispenses.
This may take time while the system fills. Flush
through at least 5 ltrs of clean water. The
fountain is supplied in clean condition but it is
the responsibility of the installer to ensure an
acceptable standard of hygiene. If necessary
carry out a sanitization procedure upon initial
installation at this point taking care to avoid
contaminating any filters as fitted. Continue to
ensure water tightness of all connections and
fittings.
5. Connect the power cord set provided into
the connection point inside the cabinet and
securely fasten the cable in the 2 cable clamps
also provided. Switch on the electrical supply.
GB