Contents Product Identification C4000 Futra Processor ......................iii Symbols and Units of Measure ............................1 Safety - C400 Controller ..............................2 Mechanical Safety ..............................2 Electrical Safety ............................... 2 Safety Precautions ..............................2 Setting up the Futra on site .............................. 3 Setting up the C4000 Futra ...............................
Compac Industries Limited reserves the right to revise or change product specifications at any time. This publication describes the state of the C4000 Futra processor at the time of publication and may not reflect the product at all times in the past or in the future.
Symbols are used in this manual to highlight information that is critical to the safety of people and equipment, and for the safe and correct operation of the Compac equipment An extreme hazard that may result in death or injury if proper precautions are not taken.
(Class 1 Zone 1, Group IIA T3). Only parts identical to those covered by the certification may be used where the integrity of the intrinsic safety may be affected. All circuit boards are to be repaired only by Compac Industries Ltd.
Once the pump/dispenser is received on site, check for any damage that may have occurred in transit, in particular damage to electronics due to vibration and jarring. This includes the checking of all terminations and plugs - including integrated circuit chips. Compac Industries Ltd. Page 3 www.compac.co.nz...
The Configuration Switch settings for the Futra software are the same as for standard pump software. Refer to the main C4000 Service Manual. These are set at Compac during manufacture and should not be changed. In the event of the Configuration code being lost and having to be re- entered, it is written on the yellow label on the C4000 Processor board cover.
The Futra Software also has several options only available when used in conjunction with a host computer running Compac NETBASE software. See the section 'Using a Host Computer with the Futra Controller' for more details.
C4000 Futra Head Futra Management Functions Futra Management Functions To enter the utility mode of operation press the ‘YES’ button or the 'NO' button on the PIN pad display when the display is showing PASS CARD. When in utility mode the Controller options are: ...
C4000 Futra Head Audit Trail Printout Audit Trail Printout After each transaction if the report printer is connected and left ON LINE, it will print a one line report including: Account/Card Number, Fleet Number (Track 1 Only), Date, Time, Reference Number, Dollars, Litres, Product, Odometer Reading (if prompted).
C4000 Futra Head Report Options Report Options The following reports are accessed via the PIN pad mounted on the pump/dispenser and will only print to a report printer set-up for current loop communications as detailed in the 'Electrical Connection' section of this manual.
Page 15
C4000 Futra Head Report Options printing of all transactions not overwritten. Print One Card Transactions This report is as for the 'Print Transactions' report except that a specific card is singled out. Delete Printed Transactions Transactions stored in the C4000 memory can only be deleted once they have been report 'printed'.
Page 16
C4000 Futra Head Report Options Accounts. Extended Validation The printout includes the following in this order: Invalidated Comcards, Invalidated (Standard) Cards and Invalidated Accounts. Limited Validation Cards The printout includes the following in this order: Validated Comcards and Validated (Standard) Cards.
This section details the Management Functions' purpose and how to set Management Functions each function manually on site. Unless stated otherwise, all of these functions can also be remotely changed by a host computer. Compac Industries Ltd. Page 11 www.compac.co.nz...
Display Load Card number and 'Enter' (Repeat until all (In)Validations are complete and press 'Clear' For Limited Validation Accounts the account must be first validated by entering 000 before the cards can be validated. Compac Industries Ltd. Page 12 www.compac.co.nz...
'Yes or 'No' to achieve the desired result Display Load Cost/Employee number Once all the Cost Centre and Employee Numbers are updated, push 'CLEAR' or leave the PIN pad to time-out from the Management Functions after ten seconds. Compac Industries Ltd. Page 13 www.compacngv.com...
Validated Cards 0000123-456-7890 Account Sub PIN No * Validated Cards 123-456 Card PIN No * 7890 * PIN numbers do not print out on the audit trail, receipts, or reports (except the card status report). Compac Industries Ltd. Page 14 www.compacngv.com...
Page 21
Load PIN # & Press 'Enter' Continue until update of PIN status is complete. Press 'Clear' to exit PIN pad Management Functions Valid User I.D. Pins are printed under a separate heading on the card status printout. Compac Industries Ltd. Page 15 www.compac.co.nz...
Four digit Price (in 1/10ths of cents) and press 'Enter' Display Load Grade # & Press 'Enter' This means the price change has been accepted. To exit Management mode press 'Clear' or wait 10 seconds for the system to time out. Compac Industries Ltd. Page 16 www.compac.co.nz...
Pass Card (This indicates that the new Pump Grade has been accepted) Grade Number Standard Setup BP Fuel Card Setup Super Diesel Unleaded Super Diesel T/Wash C/Park Kerosene AVGAS Unleaded 91 JET A1 W/bridge Water Compac Industries Ltd. Page 17 www.compacngv.com...
The pass code must be changed at the host computer as well as on site, to allow communications to take place. The Compac factory default pass code is 000000 . If the pass code is 000000, then only one 0 needs to be entered to gain access to PIN Pad, otherwise all six pass code numbers need to be entered ).
To Change Site Number Each site has a unique number. The Compac factory default site number is 000001 Site Number is arbitrary and can be set for customer convenience. Site number must be set for the Futra Controller to communicate with NETBASE.
To Change Access Code To Change Access Code The Compac Futra software can often support two Track 2 card systems simultaneously, therefore, when the system is set to Track 2 the operator will be prompted for Access Code 1 followed by Access Code 2.
'YES' OR 'NO' for the desired result Display Valid networks: XXX change? Repeat the above process until all networks are in their correct (valid or invalid) states If all networks are blocked the Controller reverts to ALL NETWORKS VALID status. Compac Industries Ltd. Page 21 www.compac.co.nz...
System And 'enter' Display Load Number & Push ENTER Load/Press The new ISO number for the second card system and press 'ENTER' Display Pass Card (this indicates the new ISO number has been accepted) Compac Industries Ltd. Page 22 www.compacngv.com...
Load number & Enter Load The new eleven digit system set-up number (obtained from the table on the next page) and push 'ENTER' Display Pass Card (this indicates that the new system number has been accepted) Compac Industries Ltd. Page 23 www.compacngv.com...
The System Set-up options are given in the following table along with their respective digit and place in the set-up code. Changing the system setup may affect the memory resulting in lost transactions. Check with Compac before changing the system setup on an existing system. Set-up...
Page 31
*Cannot be set using a host computer. i.e. The down-loaded signal is ignored by the Futra Controller. Note: The system set-up (or configuration) code is set up by Compac and should not need changing. If changes are necessary, transaction and/or totals must be printed out before hand as memory formatting may vary between different set-up modes.
Futra Controller to record certain events in the Events Log which can be uploaded on to the Host Computer for viewing and/or reporting. Events which may be recorded include: Secure PIN pad Fault Compac Controller Powered On Compac Controller Powered Off Host Computer Logged On ...
At present the following options are available COMMUNICATION METHOD Direct connection using a Compac supplied cable (BAUD RATE = 1200 Host Direct mode or 9600 for Fast Host/Cell mode) Cell connection using Wavecom modem (BAUD RATE = 1200 or 9600)
Press XX 'Enter' (e.g. 32) Display Pass Card (this indicates that the new date and time setting has been accepted) Date and Time will now be set to: 28-02-08 21:32 (28th February 2008 9:32 Compac Industries Ltd. Page 28 www.compac.co.nz...
(depending on the set up (eg odometer prompt ) is approximately 314. All transactions are uploaded to the iButton each time an upload operation is performed but are flagged as if they have been deleted or invoiced (ie. previously uploaded). Compac Industries Ltd. Page 29 www.compac.co.nz...
Check that an RS232 interface board CI-157 board has been installed (Piggy backs underneath the C4000 Power Supply This may need to be done if iButton is being retro-fitted) Wire Colour Connection on J12 Black White DTRP Green / Yellow Compac Industries Ltd. Page 30 www.compac.co.nz...
Go to the PIN pad keypad on the dispenser. Press <NO>. Enter Pass Code ( Compac factory default passcode is 000000 . If the passcode is 000000, then only one 0 needs to be entered to gain access to PINPad, otherwise all six passcode numbers need to be entered ).
If the buffer fills up, BUFFER FULL appears on the PINPad display. To delete transactions: Go to the PINPad keypad on the dispenser Press <NO> Enter Pass Code ( Compac factory default passcode is 000000) Press <ENTER> Repeatedly Press <NO> until "DELETE PRINTED TRANSACTIONS" appears on PINPad display.
1200 baud 8 bit No parity If the printer is Compac supplied it will already be setup There are no dip switches to set. All settings are made using the TEAR OFF and LF/FF buttons. To print the necessary information to set the configuration, hold down the TEAR OFF button while turning on the printer.
Outside of these time settings calls are ignored. Where more information on the above functions is required please consult the Compac NETBASE System manual. Host Computer Direct to C4000 As with the report printer the Host Computer may be temporarily or permanently connected.
Using a Host Computer Indicator LEDs Modems The C4000 Futra Controller can be fitted with a Modem to allow communications with a host computer to take place. It is important that the Futra head is configured for the type of modem being...
Page 42
Cell Modem Diagnostic LED There is a red diagnostic LED on the Cell modem. When powered up this stays ON for approx 10 seconds, it will then FLASH slowly. During a comms session it will flash faster. Compac Industries Ltd. Page 36 www.compac.co.nz...
Figure 5. Location of Power, Watchdog, RXD & TXD LEDs Power LED The Power LED (refer Figure 5) lights when the processor board has power. If this LED flashes, this indicates that the processor has a fault on Compac Industries Ltd. Page 37 www.compac.co.nz...
Page 44
When the pump is idle and in 'stand-alone' mode, the LED flashes slowly and consistently. When the pump is idle and communicating with a controller the LED flashes slowly but erratically. Compac Industries Ltd. Page 38 www.compac.co.nz...
Page 45
Indicator LEDs Indicator LEDs When the nozzle is lifted from its holster, the LED flashes quickly. Compac Industries Ltd. Page 39 www.compac.co.nz...
These include: Configuration Error The 11 digit configuration needs to be entered Clock Error Re-enter the Date and time. If the error remains, replace the memory IC. Refer to upgrade procedure for retaining data. Compac Industries Ltd. Page 40 www.compac.co.nz...
Turn on power to the C4000. Check the Pass Code, Site Number, Configuration Switch settings and Parameter Switch settings. Reset to the correct values if they have changed. If the Futra Controller Functions are not accessible using the normal Compac Industries Ltd. Page 41 www.compac.co.nz...
Page 48
Software Upgrade Procedure Software Upgrade Pass Code, enter the 'Back Door' Pass Code or contact Compac for assistance. If the PINpad display shows CONFIGURATION ERROR this means that the Futra Controller has lost the original set-up code. Enter a temporary set-up code of 000000002 for Controllers which...
Page 49
If the Futra Controller Functions are not accessible using the normal Pass Code, enter the 'Back Door' Pass Code or contact Compac for assistance. Repeat the transactions and/or totals print-out and check against the earlier print-out. Show any differences to the relevant people on site and leave them copies.