Page 1
Check the Bair Paws system website to ensure you have the most recent version of this document. www.bairpaws.com reorder #200744F Bair Paws ® Model 850 Warming Unit Operator’s Manual...
Table of Contents Introduction to the Bair Paws® Patient Adjustable Warming System .......1 Important Information about the Bair Paws Model 850 Warming Unit ......2 Indications/Intended Use ...................2 Contraindication ....................2 Warnings ......................2 Precautions ......................3 Proper Use and Maintenance ................3 Read Before Servicing Unit ................3 Preparing the Bair Paws Model 850 Warming Unit for Use ..........4...
850 can provide comfort warming. This manual includes operating instructions and unit specifications for the Model 850 warming unit. Please refer to the Instructions for Use included with the Bair Paws warming gown for more information about the gown. Bair Paws Model 850 Warming Unit...
Important Information about the Bair Paws Model 850 Warming Unit Indications/Intended Use The Model 850 warming unit is indicated for patient warming. This warming unit has been designed for use with the Bair Paws warming gowns in all preoperative and postoperative settings. Contraindication Do not apply heat to lower extremities during aortic cross-clamping.
Precautions • Do not initiate patient warming unless the Model 850 warming unit is safely placed on a hard surface or securely mounted. Otherwise, injury may result. • The Model 850 warming unit meets the international electronic interference requirements of EN 60601-1-2 and EN 55011.
Preparing the Bair Paws Model 850 Warming Unit for Use Before you begin using the warming unit, make sure that it is safely placed on a flat, hard surface such as a table, or securely mounted on a wall, IV pole, or bedrail.
Mounting the Warming Unit on an IV Pole Caution: To prevent tipping, mount the Model 850 warming unit on an IV pole at a height that ensures stability. We recommend mounting the warming unit no higher than 44 in. (112 cm) from the floor on an IV pole with a minimum wheelbase radius of 14 in.
Mounting the Warming Unit with a Rail-mount to the Wall Precaution: For use only with the Model 850 warming unit. Hook the warming unit with the attached rail-mount to the rail-to-wall bracket. Rail-to-wall bracket Bair Paws Model 850 Warming Unit Operator’s Manual...
Operating Information Instructions for Use The instructions below describe how to use the Bair Paws Model 850 warming unit with a Bair Paws gown. For more information about the Bair Paws warming gowns, refer to the Instructions for Use that is shipped with the warming gowns.
Page 10
40±3˚C. To disconnect the hose nozzle from the warming gown, press the two buttons on the sides of the nozzle and withdraw the nozzle from the hose port. Bair Paws Model 850 Warming Unit Operator’s Manual ®...
Allow the warming unit to run for at least 5 minutes. • If the “Over -Temp” light illuminates again, return the warming unit to Arizant Healthcare for service. onnect the warming unit hose to the Bair Paws gown to resume patient • Otherwise, rec warming. Arizant Healthcare Inc.
WINDEX is a registered trademark of S.C. Johnson & Son, Inc. ENVIROCIDE is a registered trademark of Metrex Research Corporation. ALCONOX is a registered trademark of Alconox, Inc. Bair Paws Model 850 Warming Unit Operator’s Manual ®...
952-947-1200 When You Call for Technical Support Please be ready to give the Technical Support Representative the serial number of your Bair Paws warming unit. The serial number is located on the back of the unit. See figure below. Repair and Exchange Call Arizant Healthcare customer service if your Model 850 warming unit requires service.
1 year This limited warranty applies only to User and is valid only for the use of Units with Bair Paws gowns. The use of any gowns or other products not manufactured or approved y Company for use with Units invalidates this limited warranty.
Technical Specifications Physical Characteristics dimensions of warming unit 11 in. high x 2.5 in. deep x 7.7 in. wide 27.9 cm high x 6.4 cm deep x 19.6 cm wide dimensions of temperature controller 2.5 in. wide x 5.8 in. long 6.4 cm wide x 14.7 cm long weight of warming unit 6.3 l;...
Page 16
285W Resistive power cord 15-foot, SJT, 3 cond., 10A device ratings 110-120 VAC, 60 Hz, 3.0 A fuses 3.0 A temperature controller cord 32” from hose collar, 4 cond., Max. voltage: 5V Bair Paws Model 850 Warming Unit Operator’s Manual ®...
Definition of Symbols The following symbols may appear on the product, on the exterior packaging, or in the product labeling. Class II Equipment Arizant Healthcare Inc.
Page 18
FAX 800-775-0002 • 952-947-1400 www.bairpaws.com Bair Hugger, Bair Paws, Arizant, Arizant Healthcare, bright ideas that work,and the Bair Paws and Arizant logos are trademarks of Arizant Healthcare Inc., registered or pending in the U.S. Patent & Trademark Office and in other countries.
Need help?
Do you have a question about the 850 and is the answer not in the manual?
Questions and answers