Janome MyLock 213D Servicing Manual
Hide thumbs Also See for MyLock 213D:

Advertisement

SERVICING MANUAL
MyLock 213D
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MyLock 213D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Janome MyLock 213D

  • Page 1 SERVICING MANUAL MyLock 213D...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TO CHANGE THE - - FACE PLATE UNIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 - - BELT COVER UNIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 - - TOP COVER - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 - - FRONT COVER UNIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6...
  • Page 3: Face Plate Unit

    TO CHANGE THE FACE PLATE UNIT To remove: 1 : Loosen the set screw A and remove the face plate unit. To attach: 2 : Fit the U-groove of the face plate between the set screw A and set plate. Put the rib of face plate into front cover unit and back cover unit and tighten the set screw.
  • Page 4: Belt Cover Unit

    TO CHANGE THE BELT COVER UNIT To remove: 1 : Loosen the set screw A and remove the set screw B. 2 : Remove the belt cover unit. To attach: 3 : Put the ribs of belt cover into front cover unit and tighten the set screws A and B.
  • Page 5: Top Cover

    TO CHANGE THE TOP COVER To remove: 1 : Remove the face plate unit and belt cover unit. 2 : Remove two set screws A and remove the top cover. To attach: 3 : Put the ribs of top cover into front cover unit and tighten set screws A.
  • Page 6: Front Cover Unit

    TO CHANGE THE FRONT COVER UNIT To remove: 1 : Remove the face plate unit and the belt cover unit. 2 : Turn the handwheel toward you with your hand, and set the upper looper at lowest position, remove set screws A, B, C, D and E, and remove front cover unit.
  • Page 7: Side Cover Unit

    TO CHANGE THE SIDE COVER UNIT To remove: 1 : Loosen the set screws A and remove the side cover unit. To attach: 2 : Fit the U-groove of the side cover between the set screws A and set plate. 3 : Tighten the set screws A.
  • Page 8: Machine Base

    TO CHANGE THE MACHINE BASE To remove: 1 : Remove screws A, B, C, D and two hinge screws E, and remove two base cushions F. 2 : Remove the machine base. To attach: 3 : Attach the machine base, and tighten screws A, B, C and D. 4 : A t tach the two base cushions F, washers, and tighten hinge screws E.
  • Page 9: Machine Socket

    TO CHANGE THE MACHINE SOCKET To remove: 1 : Remove the belt cover unit. 2 : Remove the two set screws A, and pull out the cord connectors. 3 : Remove the machine socket To attach: 4 : Insert the cord connectors as shown below. 5 : Attach the machine socket, and tighten the two screws A.
  • Page 10: To Adjust The

    TO ADJUST THE NEEDLE HEIGHT Correct setting: The distance between the tip of needle and the surface of needle plate should be 11.6 mm to 12.2 mm when the needle bar is at the highest position. To adjust: 1 : Remove the face plate unit. 2 : Turn the handwheel toward you with your hand, and set the needle bar at the highest position.
  • Page 11: Presser Bar Height

    TO ADJUST THE PRESSER BAR HEIGHT Correct setting: The distance between the surface of needle plate and bottom of presser foot should be 4.7mm to 5.3 mm when the presser bar lifter is raised. To adjust: 1 : Remove the face plate unit. 2 : Remove set screws A to remove the lamp socket unit.
  • Page 12: Feed Dog Height

    TO ADJUST THE FEED DOG HEIGHT Correct setting: When the presser foot is lowered and feed dogs are at their highest position, the distance between the surface of needle plate and bottom of presser foot should be 0.75 mm to 0.95 mm. To adjust: 1 : S e t t h e s t i t c h l e n g t h d i a l a t “...
  • Page 13: Timing Of The Needle And The Feed Dog

    TO ADJUST THE TIMING OF THE NEEDLE AND THE FEED DOG Correct setting: When the tip of the needle is at 2 - 4 mm above the needle plate in its downward motion, and lowered presser foot, the top of the feed dog teeth should be level to the top surface of needle plate at their rearmost position.
  • Page 14: Timing Of The Needle And The Upper Knife

    TO ADJUST THE TIMING OF THE NEEDLE AND THE UPPER KNIFE Correct setting: The upper knife timing is the same as that of the needle bar. In fact, when the needle bar is at highest position, the upper knife should be also at its highest position. To adjust: 1 : Remove the feed base cover.
  • Page 15: Height Of The Lower Looper

    TO ADJUST THE HEIGHT OF THE LOWER LOOPER Correct setting: The height of lower looper is 65.7 mm from center of lower looper shaft as shown in illustration. To adjust: 1 : Set the upper knife in down position to loosen set screw A. 2 : Turn the handwheel to get the lower looper in rightmost position.
  • Page 16: Clearance Between The Needles And The Lower Looper/Needle Guards

    TO ADJUST THE CLEARANCE BETWEEN THE NEEDLE AND THE LOWER LOOPER / NEEDLE GUARDS. Correct setting: The needle should have an equal clearance between the front edge of the needle holes on the needle plate. The standard clearance between the needle and the lower looper is 0 mm to 0.05 mm. The standard clearance between the needle and the rear needle guard is 0 mm to 0.2 mm.
  • Page 17 TO ADJUST THE CLEARANCE BETWEEN THE NEEDLE AND THE LOWER LOOPER / NEEDLE GUARDS.
  • Page 18: Clearance Between The Needles And The Fixed Needle Guard

    TO ADJUST THE CLEARANCE BETWEEN THE NEEDLE AND THE FIXED NEEDLE GUARD Correct setting: The clearance between needle and the fixed needle guard should be 0.1 mm to 0.4 mm. To adjust: 1 : Remove the foot and needle plate and lower the needle to its lowest position. 2 : Loosen the set screw A and adjust the position of the fixed needle guard.
  • Page 19: Position Of The Chaining Finger

    TO ADJUST THE POSITION OF THE CHAINING FINGER Correct setting: When setting the needle plate setting knob to guide line S, chaining finger should be touch to side of needle plate and tip of chaining finger should be same level to tip of needle on needle plate. To adjust: 1 : Remove the presser foot.
  • Page 20: Position Of The Upper Looper

    TO ADJUST THE POSITION OF THE UPPER LOOPER Correct setting: When the upper looper is at the leftmost position, the distance between the center of needle and the center of looper eye should be 4.8 mm to 8.2 mm To adjust: 1 : Remove the machine base.
  • Page 21: Timing Of The Needle And The Lower Looper

    TO ADJUST THE TIMING OF THE NEEDLE AND THE LOWER LOOPER Correct setting: When the needle comes up 2.8 mm to 3.2 mm from its lowest position, the tip of the lower looper comes just l e f t o f t h e n e e d l e . To adjust: 1 : Remove the presser foot, needle plate.
  • Page 22: Timing Of The Upper And Lower Loopers

    TO ADJUST THE TIMING OF THE UPPER & LOWER LOOPERS Correct setting: When lower looper moves to the right, the lower looper meets the upper looper within 0.2 mm to 1.2 mm from the left of lower looper eye at the right angle as shown in Fig. 1. To adjust: 1 : Before proceeding with this adjustment, check the lower looper timing and the position of upper looper.
  • Page 23: Clearance Between The Loopers

    TO ADJUST THE CLEARANCE BETWEEN THE LOOPERS Correct setting: When the loopers meet as shown in Fig. 2, the clearance should be 0 mm to 0.1 mm as shown in Fig. 1. To adjust: 1 : Remove the presser foot and needle plate. 2 : Turn the handwheel toward you with your hand to bring the loopers as shown in Fig.
  • Page 24: Clearance Between The Needle And The Upper Looper

    TO ADJUST THE CLEARANCE BETWEEN THE NEEDLE AND THE UPPER LOOPER Correct setting: When the upper looper meets with needle. Clearance should be : -0.05 mm to +0.05 mm. To adjust: 1 : Turn the handwheel toward you with your hand to bring the needle just behind the upper looper in downward travel.
  • Page 25: Position Of The Knives

    TO ADJUST THE POSITION OF THE KNIVES Correct setting: The top of the lower knife should be leveled with the surface of needle plate. When the upper knife is at the lowest position, the front lower corner of upper knife should be 0.8 mm to 1.5 mm below the edge of lower k n i f e .
  • Page 26: Position Of The Lower Thread Guide

    TO ADJUST THE POSITION OF THE LOWER LOOPER THREAD GUIDE Lower Looper Thread Guide (3): Loosen the set screw A, and adjust the lower looper thread guide so that the hole of thread guide is in line with the groove of lower looper as shown in Fig. 1. NOTE: After adjustment, check the lower looper thread guide (3) does not touch to arm, feed dog and feed dog base.
  • Page 27: Stitch Length

    TO ADJUST THE STITCH LENGTH Correct setting: The actual stitch length should be 2.8 mm - 3.0 mm when the stitch length dial is set at “3” and differential f e e d d i a l a t “ 0 ” . To adjust: 1 : S e t t h e s t i t c h l e n g t h d i a l a t “...
  • Page 28: Thread Tention Dials

    TO ADJUST THE THREAD TENSION DIAL Thread tension dial are already adjusted for general sewing at factory, however, if you want to adjust much stronger or weaker for special sewing, it can be adjusted as follows: To adjust: 1 : Pull out the thread tension dial. 2 : Turn the dial knob leading screw to adjust the thread tension to direction of : A to get weaker thread tension.