2 – AUTOMATIC (machine w/ alphanumeric screen)
Switch the machine on. The MAIN MENU will appear after a few seconds:
Select ASSISTED PROCEDURE.
Scroll with the down arrow (↓) and select A/C SYSTEM FLUSHING.
You may type in the vehicle license plate number and confirm with ENTER.
select the desired amount of refrigerant, then press ENTER
Press ENTER.
Empty the used oil container, the press START.
At this point, the machine will proceed automatically. When flushing is completed, disconnect
all the couplings and disconnect the machine from the power supply.
INSTRUCTIONS MANUAL
AUTOMATIC PROCEDURE
ASSISTED PROCEDURE
DATA AND CONFIGURAT.
MAINTENANCE
RECOVERY / RECYCLING
VACUUMN
X min
OIL
X ml
TRACER
X ml
FILLING
XX g
A/C SYSTEM FLUSHING
INSERT PLATE NO.
. . . . . . . . . .
Amount of gas to use for
every cycle
xxx g
press ENTER
Connect the flushing kit
and open HP and LP.
press ENTER
A/C SYSTEM FLUSHING
Empty the container
Used oil and
press START
A/C System flushing.
Gas inject.
xx g
ACp
xxx bar