Download Print this page

Wow WAC 1200PLUS Instruction Manual page 11

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
5 – AUTOMATIC (machine w/ 5" color screen)
Attention: before flushing, recover the refrigerant of the a/c system using a suitable R&R
device, then run at least 20 minutes vacuum. When flushing a system we recommend
disassembling the filter and the expansion valve, in the case of a traditional system, or only the
capillary valve in the case of a flooded system. Use the inlet to the evaporator as washing inlet
and the outlet of the condenser as flushing outlet.
From DEVICES, select A/C SYSTEM FLUSHING, the following screen will be displayed:
If needed, type the new value; then press OK to continue, the following screen will be
displayed:
Connect the flushing kit as described previously, then press OK to begin the flushing operation:
The machine will proceed automatically, displaying the quantity of oil extracted and printing the
total volume at the end of flushing. When flushing is completed, the following screen is
displayed:
Press OK, disconnect all the couplings and disconnect the machine from the power supply.
INSTRUCTIONS MANUAL
R134a
A/C SYSTEM FLUSHING
Amount of gas to use for every cycle:
xxxx
g
Press OK
A/C SYSTEM FLUSHING
R134a
connect flushing-kit as illustrated below and
press OK
A/C SYSTEM FLUSHING
R134a
A/C system flushing in progress...
A/C SYSTEM FLUSHING
R134a
end of flushing, press OK
A/C SYSTEM FLUSHING
-11-
DEVICES
DEVICES
DEVICES
DEVICES

Advertisement

loading

This manual is also suitable for:

Wac 2200