Download Print this page

Current eFlux Quick Start Manual page 3

Accessory wave pump
Hide thumbs Also See for eFlux:

Advertisement

Installation
Step 6. Plug accessorry wave pump into desired pump connection port on wave pump manifold HUB,
ensuring a drip loop is in place.
Step 7. Plug DC transformer into matching pump DC input on wave pump manifold HUB, ensuring drip
loop is in place.
AC Power
GFCI Outlet
Step 8. Follow instructions in Orbit IC manual or eFlux wave pump manual to adjust flow mode and flow
rate on wave pump.
Maintenance and Service
** Always turn wave pump OFF and disconnect DC power when servicing. Unplug and disconnect
wave pump from wave pump manifold HUB and disconnect DC power when servicing **
As your wave pumps continually run in your reef aquarium, it is best to ensure they are cleaned every 3-6
months to ensure the pump runs at optimal speed. High levels of calcium and minerals can often create
calcium deposits on the impeller, shortening the lifespan and causing excessive noise and/or lead to
failure.
To clean:
1. Turn power off to pump, disconnect both the wave pump and DC input from the wave pump manifold
HUB.
2. Carefully disassemble the wave pump from the swivel bracket and twisted the front casing of the pump
off the main pump and place in a small container. BE CAREFUL - the impeller is made of ceramic and is
breakable. Orings are all quite small, so ensure to keep all components in the small container.
3. Create a cleaning solution consisting of a 1:1 mixture of freshwater and white vinegar. Pour solution
into container and allow it to soak overnight. (Ensure connection end of pump is kept dry.)
4. Carefully re-assemble pump, rinse under freshwater and re-install into your aquarium.
24VDC
Transformer
Connect to Pump
DC Input P1, P2, P3
Connect to Pump
Connection P1, P2, P3
Page 3
eFlux Accessory Wave Pump
Wave Pump
Manifold HUB
P3
P1
P2

Advertisement