I01GeneralVehicleElectronics
2.VoltageSupply
•
2xterminal30B
•
Terminal15N
•
Terminal30F(solderedinthepowerdistributionbox).
Thereisanotherrelayforterminal30FintheBodyDomainController.
AllrelaysareactivatedbytheBDC.
2.3.8.DC/DCconverterintheEME
TheDC/DCconverterforthevoltagesupplyandthechargingofthe12 VbatteryislocatedintheEME.
2.3.9.Groundconnections
Groundconnections
Index
1
2
3
4
Explanation
GroundDrivemoduleattherightspringstrut
GroundLifemoduleintheareaofthepowerdistributionboxinthepassenger
compartment
GroundDrivemoduleattherearcrossmember
GroundDrivemoduleatthefrontcrossmember
43