4 OPERATIONAL CONSIDERATIONS

The electronic sensor device LED may be falsely activated by external EMI emitted by power
drills, wire wrap guns, or other AC powered devices located within 12 inches of the inductive
pick-up coil. If such a condition occurs, the electronic sensor device automatically resets after
the change in current state and returns to a constant dc state.

5 TROUBLESHOOTING

The LED on the bay tracer electronic sensor device is designed to light whenever an individual
jack LED is activated on a DSX bay configured with the device.
of common error conditions that may occur due to improper installation.
CONDITION
Battery return conductor inserted into coil
Labeled side of coil is facing away from the power
source
Both –48 Vdc and battery return conductors are
inserted into the coil
–48 Vdc and battery return conductors are mis-wired
on POWER connector
Page 8
© 2000, ADC Telecommunications, Inc.
Table 2. Bay Tracer Troubleshooting
DESCRIPTION
LED activates when jack is removed
LED activates when jack is removed
Bay Tracer Illuminator does not function
Bay Tracer Illuminator does not function
Table 2
provides a description