Honeywell VXP System Maintenance Manual page 60

Vibration analysis system
Table of Contents

Advertisement

Maintenance
Error
Code Component Condition
00001
N/A
Monitor Memory Usage
00002
Database Memory Usage
00003
P/U Message
10101
EPROM Checksum
101xx
10102
(Main
VXPBP DRAM Bad
10103
Board)
IRAM Bad
10104
Watchdog Fail
10105
VXPOP RAM Bad
10106
Flash Checksum
10201
102xx
Command Not Sent To DSP
10202
(Main
Data Not Sent To DSP
10203
Board)
Sent Bad Packet To DSP
10204
Receive Bad Packet From DSP
10205
DSP Receive Timeout
10206
No Ack Msg From DSP
10207
DSP Program Load Error
10208
DSP Not Active
10301
103xx (P/S&
Logic Power (5v Bad)
10302
Exp Board)
Not Used
10303
Battery Low or Dead
10304
Not Used
10501
Velo Rail Fault
105xx
10502
(Main
Velo Rail Failure
10503
Board)
Out of Calibration
106xx
None Currently Assigned
(Main
Board)
11001
110x
Velo Fault
11002
(Vib
Velo Fail
11003
Sensors)
Signal Clipped
11004
Unsteady Balance Data
11010
ICP Fail
11011
HTA Fail
11101
111xx
No Mag P/U Signal
11102
(Mag P/U)
RPM Out Of Range
4-16 Honeywell
Table 4-10. VXP Error and Action Codes
Over-
Level
write Recovery Action
I
Y
none
I
Y
none
I
N
none
E
N
user
E
N
user
E
N
user
E
N
user
E
N
user
E
Y
user
W/E
Y
internal
W/E
Y
internal
W/E
Y
internal
W/E
Y
internal
W/E
Y
internal
W/E
Y
internal
E
N
user
E
N
user
W
Y
user
E
Y
user
W
Y
internal
E
Y
user
E
N
user
W
Y
internal
E
Y
user
W
Y
prompt
W
Y
prompt
E
Y
user
E
Y
user
E
Y
user
W
Y
user
A001
A002
none
A003
A003
A003
A003
A003
A003
A004
A004
A004
A004
A004
A004
A003
A003
A004
A020
A004
A003
A007
A004
A008
A018
A018
A008
A008
A009
A010

Hide quick links: