PESOLA PTS6K-MF User Manual

Multifunctional bench scale
Hide thumbs Also See for PTS6K-MF:

Advertisement

Quick Links

User manual
Multifunctional bench scale
PTS6K-MF
PTS15K-MF 15 kg
6 kg
d=0.2g
d=0.5g

Advertisement

Table of Contents
loading

Summary of Contents for PESOLA PTS6K-MF

  • Page 1 User manual Multifunctional bench scale PTS6K-MF 6 kg d=0.2g PTS15K-MF 15 kg d=0.5g...
  • Page 2 Manual _PTS6-15K-MF_E...
  • Page 3: Table Of Contents

    Table of Contents Instructions for Use ......................1 Preparing to use the Scale ....................1 Chapter 1 Introduction ....................... 3 1-1 Features and Specifications ..................3 1-2 Display Description ....................4 1-3 Keypad Functions Description.................. 5 1-4 Power Description ....................5 1-5 Error Messages ......................
  • Page 4: Instructions For Use

    To guide you to use our product correctly, please read this User Manual carefully to extend the life of scale and to avoid error. Instructions for Use 1. Please keep scale in a cool and dry place. Do not store under high temperatures. 2.
  • Page 5 Introduction of Storage Battery: Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours. 2.
  • Page 6: Chapter 1 Introduction

    Chapter 1 Introduction 1-1 Features and Specifications 1. High performance A/D converter 0.3 uV/D high sensitivity zero point adjustable range -2mV~ +5mV Sampling speed 15 times/second use range -4mV ~ +30mV load cell stimulate power source 5V DC ±2% 100mA non-linear scale 0.01% full scale 2.
  • Page 7: Display Description

    1-2 Display Description High limit value OK value (The value between HI and LO limit value) Low limit value “Zero” indication →O← “Net weight” indication “Low battery power” indication ▼1 “Stable” indication ▼2 “Pre-Tare mode” indication ▼3 (M+) “Accumulation mode” indication ▼4 No function ▼5...
  • Page 8: Keypad Functions Description

    1-3 Keypad Functions Description  10-key model has not key and key. Press this key to select the required unit from the preset units. Press this key to preset the weight and quantity. Press this key to accumulate the weight value or others. Press this key to tare (deduct the container weight) Press this key to preset tare value.
  • Page 9: Error Messages

    Low Power Alarm Please note when the ( ) symbol keeps flashing on the left down corner of the display, the batteries should be recharged.  The scale will turn off automatically after a few hours when the low battery warning symbol shows up.
  • Page 10: Chapter 2 General Operation Description

    Chapter 2 General Operation Description 2-1 Backlight Function Press key to select the display backlight mode: “Auto Backlight” mode. When the weight is over 10d or any key is pressed, the display backlight will be switched on. When the weight returns to zero (the weight on platform is less than 10d), the display backlight will switch off after 10 seconds.
  • Page 11 Preset “Beeper value” ( Refer to Note ) e.g. Beeper value = 22   Press key 1 time the display shows   Press key 2 times the display shows   Press key 1 time the display shows ...
  • Page 12: Totalizing

    c. turn off the scale  LCD indication:            10d Low Limit High Limit ◆ To exit preset mode, press key. 2. Recall Check-weighing Values Recall “Low limit value” Press key then press Recall “High limit value”...
  • Page 13: Zero Function

    2. Clear Totalized Weight Values Press then key to clear all totalized weight values. When changing between weighing and counting mode, or selecting weighing unit, the indicator will automatically clear all the totalized weight values. The indicators will automatically clear all the totalized weight values after turning 3.
  • Page 14: Counting Function

    2. When the weight of the container is known.  Press  key; the display shows keys to input weight value of the container. After finishing the procedures, the Net indication and PreTare (PT) indication (“”) are active.  Place the goods into the container. The indicator shows the net weight of goods. ...
  • Page 15: Chapter 3 General Function Setting

    Chapter 3 General Function Setting Switch on the scale. While the scale is counting down to zero, press and hold until the display shows the software program version number Release the key, the scale enters into the configuration setting mode and is showed on the display.
  • Page 16: Check Weighing Configurations

    Check Weighing Configurations is set, accessing to is denied. key to select F4 function the display shows Press Press key for 5 times to clear HI, OK, LO values Preset “LO value” Press (LO value 10d) Press key to set “ LO value” E.g.
  • Page 17: Rs-232 Interface Output Setting (Option)

    RS-232 Interface Output Setting (option) key to select F5 function the display shows key = Increase the flash value by one (from 0 to 10) or selecting baud rate from 1200, 2400,4800 and 9600(default setting). Press key = Confirm key The display shows the default setting of transmission mode No transmission (RS-232 closed)
  • Page 18 RS-232 Interface Format I . Mode: UART Signal of EIA-RS0232 C II . Format : 1. Baud rate : 1 200, 2 400, 4 800, 9 600 bits/second 2. Data bits : 8 bits 3. Parity bit : None 4. Stop bits : 1 bit 5.
  • Page 19 HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES ) OL - Overload , Under load TR - TARE Mode ST - Display is Stable NT - NET Mode US - Display is Unstable GS - GROSS Mode DATA ( 7 or 8 BYTE ) 2B ( HEX ) = “...
  • Page 20 Press key to transmit (simple mode) WT/UNIT ( kg / lb ) - - - - - - - - - - - - - -  Press 0001 1.0000  Press 0002 1.0000  Press 0003 1.0000  Press 0004 1.0000 ...
  • Page 21 Stable Transmission (totalizing mode) WT/UNIT ( kg / lb ) - - - - - - - - - - - - - -  The scale is stable 0001 1.0000  The scale is stable 0002 1.0000  The scale is stable 0003 1.0000 ...
  • Page 22 Then the printing form is: FR”WT3N ” 1,200 0,700 0,300 0,200 000020001000000020 P1,1 key or key twice to clear the format Then, form of clearing the printing: “ “ <LF> ? <LF> TN TN TN <LF> TW TW TW TW TW TW <LF> TA TA TA <LF>...
  • Page 23: Exit Function Setting Mode

    Exit Function Setting Mode key to select F6 function the display shows Press Counting down to zero and exit setting mode Internal Value Display Mode key to select F7 function the display shows Press Internal value Press Manual _PTS6-15K-MF_E...
  • Page 24: G Value Calibration

    G value Calibration key or key to select F10 function. The display shows  You can input at most 9 sets of G value’s data. The historic data is displayed but can not to be revised. Press After about 1 second Press The screen displays revised times at present and then displays local G value after about 1 second.
  • Page 25: Id Code Setting

    ID Code Setting , , (Use must be in coordination with key or key to select F11 function the display shows Press Machine ID code setting: Press to set 01 ~ 99 Default setting: 00 (1) “00”: RS-232 does not transmit Machine ID (2) “01~99”: RS-232 transmits Machine ID Press RS232 Data format...
  • Page 26: Print Key ( ) Function Setting

    Print Key ( ) Function Setting key or key to select F12 function the display shows Press to set 0 ~ 2 Default setting: 0 Press Press key to print current weight if weight variation is within ±1d ~ ±10d, or to print accumulated weight if weight variation is over ±10d.
  • Page 27: Printing Orders When Is Set As

    Printing orders when is set as No.0 No print. No.1 TICKET NO. No.2 No.3 No.4 No.5 No.6 No.7 No.8 No print No.9 No print Contains a 9-digit code is set as  The format of is as following WT/UNIT (kg / lb) - - - - - - - - - - - - - - ...
  • Page 28 is set as The format of is as following P/N 012345678901 TICKET NO. 0001 75.01kg 0.00kg 0.00kg 75.01kg WT/UNIT ( kg / lb ) - - - - - - - - - - - - - -  Press 0001 1.0000 key or Press...
  • Page 29 Appendix 1 7-Segment Display Characters Number Display Letter Display Letter Display ℃ Manual _PTS6-15K-MF_E...
  • Page 30 Manual _PTS6-15K-MF_E...
  • Page 31 Manual _PTS6-15K-MF_E...
  • Page 32 PESOLA Präzisionswaagen AG Chaltenbodenstrasse 4A 8834 Schindellegi Switzerland Tel +41 (0)41 769 60 40 Fax +41 (0)41 769 60 42 e-mail: info@pesola.com Internet: www.pesola.com Manual _PTS6-15K-MF_E...

This manual is also suitable for:

Pts15k-mf

Table of Contents