PESOLA PTS6K-IP User Manual

Waterproof bench scale ip68 6kg d-1g

Advertisement

Quick Links

User manual
Waterproof bench scale (IP68)
PTS6K-IP
6kg
d=1g

Advertisement

Table of Contents
loading

Summary of Contents for PESOLA PTS6K-IP

  • Page 1 User manual Waterproof bench scale (IP68) PTS6K-IP d=1g...
  • Page 2 Manual_PTS6K-IP_E...
  • Page 3: Table Of Contents

    Table of Content Instructions for Use ......................1 Preparing to use the Scale ....................1 Chapter 1 Introduction ......................3 1-1 Features and Specifications ..................3 1-2 Power Supply ......................4 1-3 Panel and Keyboard Introduction ................5 1-4 Operating the Scale ....................6 1-5 Self-Test Mode ......................
  • Page 4: Instructions For Use

    To guide you to use our product correctly, please read this User Manual carefully to extend the life of scale and to avoid error. Instructions for Use 1. Please keep scale in a cool and dry place. Do not store under high temperatures. 2.
  • Page 5 Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours. 2.
  • Page 6: Chapter 1 Introduction

     Low power indication and auto power off. Specifications: Model Capacity Division Resolution 1/6,000 PTS6K-IP Operating Temperature: -10°C ~ 40°C (14°F ~ 104°F) Dimensions ::270 x 124 x 310mm (W x H x D) Weight of the scale: 3.3 kg approximately; Manual_PTS6K-IP_E...
  • Page 7: Power Supply

    1-2 Power Supply Power Supply and Power Consumption  DC 6V / 4Ah rechargeable battery  AC 100V~240V (±10%) adapter  29 mA (system no backlight) about 153 hours 80 mA (system backlight) about 50 hours  Wireless Charging (ELW Plus Wipower only) Power Supply adapter 100V~240V(50~60Hz) Output:>5W (meets WPC1.12_Qi Wireless Power Supply’s) a.
  • Page 8: Panel And Keyboard Introduction

    1-3 Panel and Keyboard Introduction RANGE 1 RANGE 2 Icon Introduction STABLE : The weight is stable. GROSS : The scale is in the gross mode. The display shows the goods and any container weight. This Gross status indication is on when the TARE function is used.
  • Page 9: Operating The Scale

    1-4 Operating the Scale POWER ON When the scale is off, press the ON/ZERO key, the scale will switch on. POWER OFF When the scale is on, press the OFF key, the scale will switch off. ZERO When the weigh pan is empty (free of load) and the display is not showing zero, press the ON/ZERO key to zero the scale.
  • Page 10: Self-Test Mode

    SIMPLE COUNTING FUNCTION (1) Use the UNITS key to enter into the “PCS” mode (2) Press the NET/GROSS key to select the counting sample size (S = 10, S = 20, S = 50, S = 100, S=200). The LCD shows in order (3) Put the samples on the weigh pan and press the UNITS key, the screen displays “------”.
  • Page 11: Error Messages

    INTERNAL VALUE MODE (must hook up Load Cell to test)  Press to enter, and the display shows internal value TARE  Please check whether the internal value has changed obviously with weight changing.  Please check the backlight.  Press key to back to the last screen , the display shows ON/ZERO KEYPAD TEST MODE...
  • Page 12: Chapter 2 Advanced Functions

    Chapter 2 Advanced Functions 2-1 Advanced Function Setting Table Below is an overview of the advanced functions. For detailed settings refer to the following sections: DISPLAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED FUNCTION setting mode Return to the ADVANCED FUNCTION setting menu Automatic backlight function setting...
  • Page 13: Advanced Function Setting Workflow

    2-2 Advanced Function Setting Workflow In the weighing mode, press the keys at the same time to NET/GROSS ON/ZERO enter the Advanced Function setting mode. The LCD shows Overall workflow of the Advanced Function setting mode: Press UNITS key Press ON/ZERO key Press UNITS key Press ON/ZERO key Press UNITS key...
  • Page 14: General Function Setting

    2-3 General Function Setting Workflow of the General Function setting: DISPLAY NOTE ACTIONS Press TARE ON/ZERO key Upward key (from 0 to 9) UNITS key Downward key (from 9 to 0) TARE key Move the cursor to right Use the keys to select NET/GROSS key Move the cursor to left the function...
  • Page 15: Automatic Backlight Function Setting

    2-3-1 Automatic Backlight Function Setting Select in the General Function setting mode to change the backlight function setting. NOTE ACTIONS DISPLAY Press TARE LCD displays the last saved status ON/ZERO UNITS key to select function “on” or “off” Press TARE Key in the parameter “00”...
  • Page 16: Automatic Power-Off Timer Setting

    2-3-2 Automatic Power-off Timer Setting Select in the General Function setting mode to change the automatic power-off timer setting. DISPLAY NOTE ACTIONS Press TARE key LCD displays the last saved status Use ON/ZERO or UNITS key Automatic power-off timer setting to key in parameter key to key in ON/ZERO...
  • Page 17: Hi/Lo/Ok Function Setting

    2-3-3 Hi/Lo/OK Function Setting Select in the General Function setting mode to set the Hi/Lo/OK function. This function is available in all unit modes. In one specific unit mode, enter to set the Hi/Lo/OK values.  When the high limit and low limit are both set as “0”, the Hi/Lo/OK function is disabled. DISPLAY NOTE ACTIONS...
  • Page 18: Restore To The Default Setting

    2-3-4 Restore to the Default Setting Select in the General Function setting mode to restore to the default setting. DISPLAY NOTE ACTIONS Return (Cancel the Press TARE key restoration) Restore to the default Use ON/ZERO or UNITS keys setting to select “return” or “format” Press TARE key Key in the parameter “00”...
  • Page 19: Noise Filter Setting

    2-3-5 Noise Filter Setting Select in the General Function setting mode to set the noise filter setting.  When modifying , the parameters of remain un-altered. DISPLAY NOTE ACTIONS Returning to zero point setting LCD displays the last saved status Press TARE key Returning to the zero point setting Use ON/ZERO or UNITS key to key in the...
  • Page 20: Hold Function Setting

    2-3-6 Hold Function Setting Select in the General Function setting mode to set the Hold function. ACTIONS NOTE DISPLAY Press TARE key Hold function setting LCD displays the last saved parameter setting Hold function setting Use ON/ZERO or UNITS key keys to key in the ON/ZERO UNITS...
  • Page 21: Auto Unit Weight Averaging Setting

    2-3-7 Auto Unit Weight Averaging Setting Select in the General Function setting mode to set Auto Unit Weight Averaging. ACTIONS NOTE DISPLAY Press TARE key Auto unit weight averaging setting LCD displays the last saved parameter setting Use ON/ZERO or UNITS key Auto unit weight averaging setting to key in the parameters keys to key in the...
  • Page 22: Two Weighing Units Setting

    2-3-8 Two Weighing Units Setting Select in the General Function setting mode to set the two weighing units setting. Two weighing units setting LCD displays the last saved parameter setting Press Two weighing units setting TARE key to key in the ON|ZERO UNITS parameters for two weighing units...
  • Page 23: Unstable Tare

    2-3-9 Unstable Tare Unstable Tare setting LCD displays the last saved parameter setting Press TARE Unstable Tare setting key to key in the ON|ZERO UNITS parameters for second weighing unit Default setting = 0 Disable tare operation while unstable Enable tare operation while unstable ON|ZERO UNITS to key in the parameters...
  • Page 24: Weight Calibration

    2-4 Weight Calibration In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows Use the NET/GROSS or UNITS key to select to enter the weight calibration mode. NOTE DISPLAY ACTIONS...
  • Page 25: Appendix 1 Command Mode &Output Data Format

    Appendix 1 Command Mode &Output data format  only work with models have WIFI card or BLE card installed inside  Command Mode Command Format A Host Command Slave Command Zero Switch to the first weighing unit Tare Switch to the second weighing unit Gross weight Net weight Clear TARE value...
  • Page 26 Note:  (Weighing unit) is various depended on models The first weighing unit WS00HI001000<CR><LF> Write HIGH values ANS: WS00HI001000<CR><LF> Command Format D Host Data Slave Value (e.g. Price) Position of decimal point When the Slave receives this data format, it will transfer the data and display it on its LCD. ˙...
  • Page 27: Appendix 2 7-Segment Display Characters

    Appendix 2 7-Segment Display Characters Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter Manual_PTS6K-IP_E...
  • Page 28 PESOLA Präzisionswaagen AG Chaltenbodenstrasse 4A 8834 Schindellegi Switzerland Tel +41 (0)41 769 60 40 Fax +41 (0)41 769 60 42 e-mail: info@pesola.com Internet: www.pesola.com Manual_PTS6K-IP_E...