Error Messages - HTC DURATIQ T5 User Manual

Table of Contents

Advertisement

HTC DURATIQ
Symbol
VOLTAGE LOW

9.5.2 Error Messages

Symbol
CANBUS ERROR
EMERGENCY STOP
ACTIVATED
GENERIC INVERTOR
ERROR
GENERIC........ ERROR
(error code)
HEATSINK
TEMPERATURE HIGH
INVERTER OVERLOAD
MOTOR NOT
CONNECTED
MOTOR OVERHEAT
MOTOR OVERLOAD
MOTOR SHORT
CIRCUIT
54
Warning
Error Message
www.htc-floorsystems.com
Fault description
Low input voltage to
machine.
Fault description
Error on CAN bus.
Emergency stop
activated.
Generic error converter.
Generic error converter.
Cooling flange for
frequency converter is
overheated.
The converter is
overloaded.
Break in grinding
motor/grinding motor
cabling.
Grinding motor is
overheated.
Grinding motor becomes
overloaded. Overload
meter up to 100%.
Grinding motor
short-circuited.
Troubleshooting
Action
Check voltage level
during operation.
Check cable area.
Check electrical supply.
Action
Check cabling. Check
units connected to
HMI.
Reset emergency stop.
Go to
www.htc-
floorsystem.com and
select support.
Fans are not standard.
Recommended for
ambient temperatures
>30°C.
Let the frequency
converter cool down.
Let the machine cool
down.
Check grinding motor
cabling. Check
measure grinding
motor.
Let the motor cool
down.
Let the machine cool
down.
Check grinding motor
cabling. Insulation
measure grinding
motor.
D004753, 01.01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents