PB 36 & 564 25K CoolSmart TV
564 25K Installation Requirements
Upper Manifold Framing
Ceiling
Min. 1-1/2" (39mm)
Max. 120"
(3048mm)
Min. 70-7/8"
(1801mm)
564 25K Reduced Mantel Height
When using this kit, disregard the combustible
mantel requirements in the manual and follow the
requirements shown to the right.
If you wish to place a TV above the mantel, it must
meet the following requirements:
Minimum 1" air gap behind TV to wall.
The mantel must extend 2" in front of the
TV and 1" to both sides.
Page 6 of 12
1-1/4" (32mm)
1-3/4" (45mm)
3/4" (20mm)
Manifold
3-3/4"
(96mm)
Lower Manifold Framing
Max. 4-1/4"
(108mm)
Min. 1" Clearance from
Flex Duct to Combustibles
Fireplace Header
564 25K
Fireplace
(CF or Std)
17602034- 7/11/19
(sku# 98900778)
Min. 1-1/4" (32mm)
3/8" (10mm)
Clearance from Top, Sides
and Back to Combustibles
Manifold Support Bracket
Max. 1-1/2" (39mm)
Max. 4-1/4" (108mm)
Max. 3"
(77mm)
5" (127mm) Alum. Flex Duct
(included)
Max. 12" (305mm)
Combustible
Mantel
Min.33-1/4"
(844mm)
Min. 3-1/2"
(89mm)
Min. 1/2" (13mm)
Min. 3-1/2"
(89mm)
564 25K
Fireplace
(CF or Std)
© Travis Industries, Inc.