System Settings - gefran eView HD 101 Operating Instructions Manual

Table of Contents

Advertisement

eX Series 700 HMI products have a system settings interface
to allow configuration of system options.
The user interface of System Settings is based on HTML
pages accessible from the HMI screen or remotely using a
Web browser Chrome v44 or higher using port 443. To connect
The active item of menu is highlighted on the left side of the
screen. The right side shows related information and settings.
Depending on the size of the HMI screen, both menu and
content of selected item may be shown on screen at the
same time or not.
System Settings has two modes of operation:
User Mode
GF Designer HD runtime is running or
System Mode
the HMI device is in "factory default"
status.
GF Designer HD runtime is not running
or the HMI device has a software
failure.
System Mode includes all options
available in User Mode and additionally
includes commands dedicated to
system upgrade and recovery not
available when running in User Mode.
Activation of System Settings in User Mode:
Factory default
Press "System Setting" button on the
status
HMI screen
GF Designer HD
Recall context menu and select
runtime running
"System Settings". To recall the
context menu click and hold any
unused area of the touchscreen for a
few seconds. Default hold time is 2
seconds.
80587_eView HD_02-2019_ENG

10. SYSTEM SETTINGS

enter the address https:// IP/machine_config where IP is the
IP address of the HMI device. Default username is "admin",
default password is "admin". Use navigation menu on the left
side of the screen to browse through the available options.
Activation of Systems Settings in System Mode:
Normal
If GF Designer HD runtime is not
operation
running: Press "System Setting" button
on the device screen to recall System
Settings in User Mode. Select "Restart"
-> "Config OS" to reboot in System
Mode.
If GF Designer HD runtime is running:
recall context menu and select
"System Settings". To recall the
context menu click and hold any
unused area of the touchscreen for a
few seconds. Default hold time is 2
seconds to enter in System Settings in
User Mode. Select "Restart" -> "Config
OS" to reboot in System Mode.
Recovery
If device is not responsive, use the so-
operation
called "tap-tap" procedure
This procedure consists in tapping
the surface of the touchscreen during
the device power-up phase. Tapping
frequency must be high.
You have to start tapping the
touchscreen as soon as power has
been applied to the device. When the
sequence has been recognized, the
system shows the message: "TAP-TAP
DETECTED". At this point release
touch to boot in User Mode without
running GF Designer HD runtime or
press and hold few seconds (selecting
so "RESTART: CONFIG OS") to boot in
System Mode.
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eview hd seriesEview hd 156Eview hd 070Eview hd 215

Table of Contents