9

FIELD SERVICING

9.1

TROUBLE SHOOTING

The following is a brief diagnostic aid intended to assist the user in determining the nature of problems
encountered during the operation of VideoRay.
1) Check to see that the electrical outlet is live.
2) Ensure all power switches are turned on.
3) Check all the cables for proper connection.
4) Check the main fuse in the power supply. (Disconnect power before checking)
5) Check the tether and connectors for damage.
9.1.1

LIGHTS DO NOT WORK

1) Check for power to the vehicle.
2) Check to see if the bulbs have burned out.
9.1.2

LOSS OF THRUST OR MANEUVERABILITY

1) Ensure the propellers and shafts are clear of debris.
2) Ensure the propellers are securely installed.
3) Check to see if the tether is snagged.
4) Check the thrusters to ensure they function properly with VideoRay out of the water.
9.1.3

VIDEO MONITOR DOES NOT SHOW PICTURE

1) Ensure the Video Monitor is plugged into a live electrical outlet.
2) Check all the video connections.
3) Check to see the VideoRay is turned on.
4) Try a different monitor.
9.1.4

POOR PICTURE QUALITY

1) Check for proper cable connections.
2) Check the condition of the connectors. In our experience, poor video cables and video connectors cause
many video failures.
3) Check for tether damage.
4) Ensure that the view port on VideoRay is clean and free of condensation.
5) Try a different monitor.