2.2. Special tools for R410A
Tool name
Pressure is high and cannot be measured with a conven-
tional (R22) gauge. To prevent erroneous mixing of other
Gauge manifold
refrigerants, the diameter of each port has been changed.
It is recommended the gauge with seals -0.1 to 5.3 MPa
(30 inHg to 768 psi) for high pressure.
-0.1 to 3.8 MPa (30 inHg to 551 psi) for low pressure.
To increase pressure resistance, the hose material and base
Charge hose
size were changed.
A conventional vacuum pump can be used by installing a
Vacuum pump
vacuum pump adapter.
Gas leakage detector
Special gas leakage detector for HFC refrigerant R410A.
Copper pipes
It is necessary to use seamless copper pipes and it is desirable that the amount of residual
oil is less than 40 mg/10 m (0.004 oz/100 ft.). Do not use copper pipes having a collapsed,
deformed or discolored portion (especially on the interior surface). Otherwise, the expansion
value or capillary tube may become blocked with contaminants.
As an air conditioner using R410A incurs pressure higher than when using R22, it is nec-
essary to choose adequate materials.
Do not use the existing (for R22) piping and fl are nuts.
If the existing materials are used, the pressure inside the refrigerant cycle will rise and
cause failure, injury, etc. (Use the special R410A materials.)
When installing and relocating the air conditioner, do not mix gases other than the
specifi ed refrigerant (R410A) to enter the refrigerant cycle.
If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise to
an abnormally high value and cause failure, injury, etc.
2.3. For authorized service personnel only.
For the air conditioner to operate satisfactorily, install it as outlined in this installation
manual.
Connect the indoor unit and outdoor unit or branch box with the air conditioner piping
and cables available from your local distributor. This installation manual describes the
correct connections using the installation set available from your local distributor.
Do not turn on the power until all installation work is complete.
This installation manual describes how to install the indoor unit only.
To install the outdoor unit or branch box, refer to the installation manual included with
the outdoor unit or branch box.
• Be careful not to scratch the air conditioner when handling it.
• After installation, explain correct operation to the customer, using the operating manual.
1 ] 1
2.4. Accessories
The following installation accessories are supplied. Use them as required.
Name and Shape
Operating Manual
Installation Manual
(This manual)
Wall hook bracket
Contents of change
WARNING
WARNING
CAUTION
Q'ty
Name and Shape
Remote
controller
holder
1
Cloth tape
1
Tapping screw
(M4 × 25 mm)
1
Name and Shape
Remote
controller
Battery
Cable tie
The following items are necessary to install this air conditioner. (The items are not
included with the air conditioner and must be purchased separately.)
Name
Connection pipe assembly
Connection cable (4-conductor)
Wall pipe
Decorative tape
Vinyl tape
1
2.5. Optional parts
Refer to each installation manual for the method of installing optional parts.
Parts name
Wired Remote Controller
Simple Remote Controller
External connect kit

3. GENERAL SPECIFICATION

This INSTALLATION MANUAL briefl y outlines where and how to install the air conditioning
system. Please read over the entire set of instructions for the indoor and outdoor units and
make sure all accessory parts listed are with the system before beginning.
] 1
3.1. Type of copper pipe and insulation material
Refer to the installation manual for the outdoor unit for description of allowable pipe
length and height difference.
MODEL
9,000 Btu/h model
12,000 Btu/h model
15,000 Btu/h model
MAX.
20 m (65 ft.)
Q'ty
Install heat insulation around both the gas and liquid pipes. Failure to do so may
cause water leaks.
Use heat insulation with heat resistance above 120 °C (248 °F). Reverse cycle model
only.
In addition, if the humidity level at the installation location of the refrigerant piping is
1
expected to exceed 70%, install heat insulation around the refrigerant piping. If the
expected humidity level is 70-80%, use heat insulation that is 15 mm (19/32 in.) or
thicker and if the expected humidity exceeds 80%, use heat insulation that is 20 mm
(25/32 in.) or thicker.
If heat insulation is used that is not as thick as specifi ed, condensation may form on
the surface of the insulation. In addition, use heat insulation with heat conductivity of
0.045 W/(m•K) or less (at [20 °C (68 °F)]).
1
] 1
3.2. Additional materials required for installation
A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire (See your local electrical codes.)
C. Putty
9
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping
]
1
Q'ty
Name and Shape
Tapping screw
(M3 × 12 mm)
1
Air cleaning filter
2
1
Q'ty
Name
1
Wall cap
1
Saddle
1
Drain hose
1
Tapping screws
1
Sealant
Model No.
Application
UTY-RNNUM
For air conditioner operation
UTY-RSNUM
For air conditioner operation
UTY-XWZXZ5
For control input/output port
CAUTION
Diameter
Liquid pipe
Gas pipe
6.35 mm (1/4 in.)
9.52 mm (3/8 in.)
6.35 mm (1/4 in.)
9.52 mm (3/8 in.)
6.35 mm (1/4 in.)
12.70 mm (1/2 in.)
Pipe length
MIN.
3 m (10 ft.)
CAUTION
Q'ty
2
2
Q'ty
1
1 set
1
1 set
1
En-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents