PR electronics 5420B Manual

Ex power supply
Hide thumbs Also See for 5420B:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Ex interfaces
Interfaces
for
analogue
signals as well as HART
signals between sensors / I/P
®
converters / frequency signals and control systems in Ex
zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.
Isolation
Galvanic isolators for analogue and digital
signals as well as HART
signals. A wide product range
®
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specific to universal transmitters.
Universal
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
and
digital
5 4 2 0 B
E x P o w e r S up p l y
N o . 5 4 2 0 B V 1 0 2 - I N ( 1 0 0 7 )
F r o m s e r . n o . 0 3 0 1 4 5 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 13
UK
Page 25
FR
Seite 37
DE
Messtechnik
MTS
Schaffhausen GmbH
CH- 8260 Stein am Rhein
Telefon + 41 52-672 50 00
Messen Prüfen Automatisieren www.mts.ch

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5420B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PR electronics 5420B

  • Page 1 Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces analogue digital signals as well as HART signals between sensors / I/P ®...
  • Page 2: Table Of Contents

    Ex SPÆNDINGSFORSYNING PRepower 5420B Indholdsfortegnelse Advarsler................Sikkerhedsregler..............EF-overensstemmelserklæring..........Adskillelse.af.SYSTEM.5000..........Anvendelse................Teknisk.karakteristik............. Montage./.installation............Applikationer............... . Bestillingsskema..............Elektriske.specifikationer............ . Tilslutninger................11...
  • Page 3: Sikkerhedsregler

    FaRLIG . Adskillelse.af.modulet.for.indstilling.af.omskiftere.og.jumpere.. Operatører er.personer,.som.under.normal.drift.med.produktet,.skal.indstille. SPÆNDING . Installation,.ledningsmontage.og.-demontage.. og.betjene.produktets.trykknapper.eller.potentiometre,.og.som.er.gjort.bekendt. . Fejlfinding.på.modulet.. med.indholdet.af.denne.manual.. Reparation af modulet og udskiftning af sikringer må kun MODTaGELSE OG uDPaKNING: foretages af PR electronics a/S. Udpak.modulet.uden.at.beskadige.dette,.og.sørg.for,.at.manualen.altid.følger. modulet.og.er.tilgængelig..Indpakningen.bør.følge.modulet,.indtil.dette.er.mon- teret.på.blivende.plads.. Kontrollér.ved.modtagelsen,.at.modultypen.svarer.til.den.bestilte. aDVaRSEL MILjøFORHOLD: Undgå.direkte.sollys,.kraftigt.støv.eller.varme,.mekaniske.rystelser.og.stød,.og. udsæt.ikke.modulet.for.regn.eller.kraftig.fugt..Om.nødvendigt.skal.opvarmning,. SYSTEM.5000.skal.monteres.på.DIN.skinne.efter.DIN.46277.. udover.de.opgivne.grænser.for.omgivelsestemperatur,.forhindres.ved.hjælp.af.
  • Page 4: Ef-Overensstemmelserklæring

    EF-OVERENSSTEMMELSESERKLÆRING INSTaLLaTION: Modulet.må.kun.tilsluttes.af.teknikere,.som.er.bekendte.med.de.tekniske. udtryk,.advarsler.og.instruktioner.i.manualen,.og.som.vil.følge.disse.. Som.producent.erklærer Hvis.der.er.tvivl.om.modulets.rette.håndtering,.skal.der.rettes.henvendelse.til. PR electronics a/S den.lokale.forhandler.eller.alternativt.direkte.til:. Lerbakken 10 PR electronics a/S, Lerbakken 10, 8410 Rønde, Danmark tlf: +45 86 37 26 77. DK-8410 Rønde hermed.at.følgende.produkt: Installation.og.tilslutning.af.modulet.skal.følge.landets.gældende.regler.for. installation.af.elektrisk.materiel.bl.a..med.hensyn.til.ledningstværsnit,.for-sikring. Type: 5420B og.placering.. Navn: Ex Spændingsforsyning Beskrivelse.af.indgang/udgang.og.forsyningsforbindelser.findes.på.blokdia- grammet.og.sideskiltet.. er.i.overensstemmelse.med.følgende.direktiver.og.standarder: For.moduler,.som.er.permanent.tilsluttet.farlig.spænding.gælder:...
  • Page 5: Adskillelse.af.system.5000

    SYSTEM 5000 Ex SPÆNDINGSFORSYNING Husk først at demontere tilslutningsklemmerne med farlig spænding. PRepower 5420B Billede 1: •.2-kanaler.. Modulet.frigøres.fra.DIN-skinnen.ved. at.løfte.i.den.nederste.lås.. •.5-port.3,75.kVAC.galvanisk.isolation. •.Udgangsspænding.>.18.V.til.Ex-område. •.Detektering.af.aktiv.strømsløjfe. •.Universel.forsyning.med.AC.eller.DC anvendelse: •. Spændingsforsyning.med.sikkerhedsbarriere.til.forsyning.af.udstyr.placeret.i. eksplosionsfarligt.område. •. Spændingsforsyning.med.failsafe.detektering.af.aktiv.strømsløjfe.fra.2-tråd- Billede 2: Printet.udtages.ved.at.løfte.i.den. stransmittere.placeret.i.eksplosionsfarligt.område. øverste.lås.og.samtidig.trække.ud.i. Teknisk karakteristik: frontpladen.. Nu.kan.switche.og.jumpere.ændres.
  • Page 6: Bestillingsskema

    Bestillingsskema: 5420B 2-Trådstransmitter Type Kanal Loop alarm 5420B Dobbelt Forsy- ning Elektriske specifikationer: Specifikationsområde: 2-Trådstransmitter -20°C.til.+60°C Loop Fælles specifikationer: alarm Sikring............400.mA.T./.250.VAC Isolationsspænding,.test/drift......3,75.kVAC./.250.VAC Kalibreringstemperatur........20...28°C Forsy- ning EMC-Immunitetspåvirkning........<.±0,5% Udvidet.EMC-immunitet:. NAMUR.NE.21,.A.kriterium,.gniststøj....<.±1% . flerkoret.ledning Ledningskvadrat.(max.).........
  • Page 7 Indgang: Forsyningsspænding.universel...... 21,6...253.VAC 50...60.Hz. 19,2...300.VDC Egetforbrug........... ≤.2.W.(2.kanaler) Max..forbrug..........≤.4.W.(2.kanaler) udgange: Udgangsspænding........>.18.VDC.ved.20.mA Udgangsstrøm,.pr..kanal.(Max.)....28.mA Relæudgange: Trukket.indenfor.grænse....... >.3,8...<.20,5.mA V-max............. 2 50.VRMS I-max.............. 2 .ARMS Max..AC.effekt..........1 00.VA Max..belastning.ved.24.VDC......1.A EEx- / I.S.-godkendelse: DEMKO.99ATEX126256........II.(1).GD [EEx.ia].IIC.
  • Page 8 Ex POWER SuPPLY PRepower 5420B Table of contents Warnings................14 Safety.instructions..............15 EC.Declaration.of.Conformity..........17 How.to.demount.SYSTEM.5000......... . 18 Application................19 Technical.characteristics............19 Mounting./.installation............19 Applications................20 Order...................
  • Page 9: Warnings

    VOLTaGE . and.jumpers.. RECEIPT aND uNPaCKING: . General.mounting,.wire.connection.and.disconnection.. Unpack.the.module.without.damaging.it.and.make.sure.that.the.manual.always. . Troubleshooting.the.module.. follows.the.module.and.is.always.available..The.packing.should.always.follow. the.module.until.this.has.been.permanently.mounted.. Repair of the module and replacement of circuit breakers Check.at.the.receipt.of.the.module.whether.the.type.corresponds.to.the.one. must be done by PR electronics a/S only. ordered.. ENVIRONMENT: WaRNING! Avoid.direct.sun.light,.dust,.high.temperatures,.mechanical.vibrations.and. shock,.and.rain.and.heavy.moisture..If.necessary,.heating.in.excess.of.the. SYSTEM.5000.must.be.mounted.on.DIN.rail.according.to.DIN. stated.limits.for.ambient.temperatures.should.be.avoided.by.way.of.ventilation.. 46277.. All.modules.fall.under.Installation.Category.II,.Pollution.Degree.1,.and.Insulation.
  • Page 10: Ec.declaration.of.conformity

    EC DECLaRaTION OF CONFORMITY MOuNTING: Only.technicians,.who.are.familiar.with.the.technical.terms,.warnings,.and. instructions.in.the.manual.and.who.are.able.to.follow.these,.should.connect.the. As.manufacturer module..Should.there.be.any.doubt.as.to.the.correct.handling.of.the.module,. PR electronics a/S please.contact.your.local.distributor.or,.alternatively,.. Lerbakken 10 PR electronics a/S, Lerbakken 10, DK-8410 Rønde, Denmark, DK-8410 Rønde tel: +45 86 37 26 77. hereby.declares.that.the.following.product: Mounting.and.connection.of.the.module.should.comply.with.national.legislation. Type: 5420B for.mounting.of.electric.materials,.i.e..wire.cross.section,.protective.fuse,.and. Name: Ex power supply location..Descriptions.of.input/output.and.supply.connections.are.shown.in.the.
  • Page 11: How.to.demount.system.5000

    HOW TO DEMOuNT SYSTEM 5000 Ex POWER SuPPLY First, remember to demount the connectors with hazardous voltages. PRepower 5420B Picture 1: •.2.channels. By.lifting.the.bottom.lock,.the.module. is.detached.from.the.DIN.rail.. •.5-port.3.75.kVAC.galvanic.isolation. •.Output.voltage.>.18.V.to.Ex.area. •.Active.current.loop.detection. •.Universal.supply.by.AC.or.DC application: •. Voltage.supply.with.safety.barrier.for.the.supply.of.equipment.mounted.in. hazardous.area. Picture 2: •. Voltage.supply.with.failsafe.detection.of.active.current.loop.from.2-wire. Then,.by.lifting.the.upper.lock.and. transmitters.mounted.in.hazardous.area. pulling.the.front.plate.simultaneously. the.PCB.is.removed..
  • Page 12: Order

    Order : 5420B 2-wire transmitter Type Channel Loop alarm 5420B Double Supply Electrical specifications: Specification range: 2-wire transmitter -20°C.to.+60°C Loop Common specifications: alarm Fuse............... 400.mA.SB./.250.VAC Isolation.voltage,.test/operation....3.75.kVAC./.250.VAC Calibration.temperature........ 20...28°C Supply EMC.-.immunity.influence........<.±0.5% Extended.EMC.immunity: NAMUR.NE.21,.A.criterion,.burst......<.±1% Max..wire.size.
  • Page 13: Connections

    Connections: Input: Supply.voltage.universal....... 21.6...253.VAC 50...60.Hz Supply: 19.2...300.VDC Internal.consumption........≤.2.W.(2.channels) Max..consumption........≤.4.W.(2.channels) Outputs: Output.voltage..........>.18.VDC.at.20.mA Output.current.per.channel.(max.)....28.mA Relay outputs: Safe area: ON.within.limit..........>.3.8...<.20.5.mA Vmax.............. 2 50.VRMS Loop alarm Imax..............2 .ARMS Max..AC.output..........1 00.VA Max..load.at.24.VDC........1.A EEx / I.S.
  • Page 14 Ex PRepower 5420B SOMMaIRE Avertissements..............26 Consignes.de.sécurité............27 Déclaration.de.conformité.CE..........29 Démontage.du.SYSTEME.5000.......... . 30 Applications................31 Caractéristiques.techniques..........32 Montage./.installation............32 Applications................32 Référence................33.
  • Page 15: Avertissements

    TENSION RECEPTION ET DEBaLLaGE pour.régler.les.commutateurs.DIP.et.les.cavaliers,.montage. DaNGE- Déballez.le.module.sans.l’endommager..Le.guide.doit.toujours.être.disponible. général,.raccordement.et.débranchement.de.fils.et.recherche. REuSE et.se.trouver.à.proximité.du.module..De.même,.il.est.recommandé.de.conserver. de.pannes.sur.le.module.. l’emballage.du.module.tant.que.ce.dernier.n’est.pas.définitivement.monté..A. la.réception.du.module,.vérifiez.que.le.type.de.module.reçu.correspond.à.celui. Seule PR electronics SaRL est autorisée à réparer le module que.vous.avez.commandé.. et à remplacer les fusibles. ENVIRONNEMENT N’exposez.pas.votre.module.aux.rayons.directs.du.soleil.et.choisissez.un. endroit.à.humidité.modérée.et.à.l’abri.de.la.poussière,.des.températures. aVERTISSEMENT ! élevées,.des.chocs.et.des.vibrations.mécaniques.et.de.la.pluie..Le.cas.échéant,. Il.convient.de.monter.l’appareil.SYSTEM.5000.sur.un.rail.DIN. des.systèmes.de.ventilation.permettent.d’éviter.qu’une.pièce.soit.chauffée.au- en.se.conformant.à.la.norme.DIN.46277..Le.connecteur.de. delà.des.limites.prescrites.pour.les.températures.ambiantes...
  • Page 16: Déclaration.de.conformité.ce

    En.tant.que.fabricant Bron.Cedex.(tél..:.(0).472.140.607).ou.à.PR.electronics.A/S,.Lerbakken.10,.DK- PR electronics a/S 8410.Rønde,.Danemark.(tél..:.+45.86.37.26.77)... Lerbakken 10 Le.montage.et.le.reccordement.du.module.doivent.être.conformes.à.la. DK-8410 Rønde législation.nationale.en.vigueur.pour.le.montage.de.matéri. a ux.électriques,.par. déclare.que.le.produit.suivant.: exemple,.diamètres.des.fils,.fusibles.de.protection.et.implantation.des.modules.. Les.connexions.des.alimentations.et.des.entrées./.sorties.sont.décrites.dans.le. Type : 5420B schéma.de.principe.de.la.fiche.technique.et.sur.l’étiquette.de.la.face.latérale.du. Nom : alimentation Ex module.. Les.instructions.suivantes.s’appliquent.aux.modules.fixes.connectés.en. correspond.aux.directives.et.normes.suivantes.: tensions.dangereu. s es.:. Le.fusible.de.protection.doit.être.de.10.A.au.maximum..Ce.dernier,. La.directive.CEM.(EMC).2004/108/CE.et.les.modifications.subséquentes ainsi.que.l’interrupteur.général,.doivent.être.facilement.accessibles.et. EN 61 326-1 à.proximité.du.module..Il.est.recommandé.de.placer.sur.l’interupteur. général.une.étiquette.indiquant.que.ce.dernier.mettra.le.module.hors.
  • Page 17: Démontage.du.systeme.5000

    DEMONTaGE Du SYSTEME 5000 aLIMENTaTION Ex Tout.d’abord,.n’oubliez.pas.de.démonter.les.connecteurs.où.règnent.des. PRepower 5420B tensions.dangereuses. •.Deux.voies.. Figure 1 : Débloquez.le.verrou.inférieur.pour. •.Isolation.galvanique.5-port.de.3,75.kVca.. dégager.le.module.du.rail.DIN.. •.Alimentation.Ex.>.18.V.. •.Surveillance.de.la.boucle.Ex. •.Alimentation.multi-tension.ca.ou.cc applications : •. Alimentation.de.tension.avec.la.barrière.SI.pour.l’alimentation.des.modules. situés.en.zone.dangereuse. •. Alimentation.Ex.avec.surveillance.de.la.boucle.de.courant. Figure 2 : Caractéristiques techniques : Puis,.débloquez.le.verrou.supérieur. tout.en.extrayant.la.plaque.avant.:. •. Le.PR5420B.dispose.d’un.relais.par.voie.en.zone.non.dangereuse..Les.relais. la.carte.à.circuits.imprimés.est.alors. s’ouvrent.quand.le.courant.de.la.boucle.SI.correspondante.est.en.dehors.des. dégagée...
  • Page 18: Référence

    Transmetteur 2-fils Référence : 5420B Alarme de boucle Type Voie Alimen- 5420B Deux tation Spécifications : Transmetteur 2-fils Plage de température : Alarme de boucle -20°C.til.+60°C Caractéristiques communes : Fusible............400.mA.T./.250.Vca Alimen- Tension.d’isolation,.test/opération....3,75.kVca./.250.Vca tation Température.d’étalonnage......20...28°C Immunité.CEM............<.±0,5% Immunité.CEM.améliorée.:.
  • Page 19: Connexions

    Connexions : Entrée : Tension.d’alimentation.multi-tension.... 21,6...2530.Vca 50...60.Hz. Alimentation : 19,2...300.Vcc Consommation.interne........ . ≤.2.W.(2.voies) Consommation.max........≤.4.W.(2.voies) Sorties : Sortie.tension..........>.18.Vcc.à.20.mA Sortie.courant.par.voie.(max.)....... 28.mA Sorties relais : Zone non dangereuse : Actif.en.dehors.limite........>.3,8...<.20,5.mA V.max............. 2 50.VRMS Alarme de boucle I.max.
  • Page 20 Ex-SPaNNuNGSVERSORGuNG PRepower 5420B Inhaltverzeichnis Warnung................38 Sicherheitsregeln..............39 EG-Konformitätserklärung........... . 41 Zerlegung.des.SYSTEMs.5000..........42 Verwendung................43 Technische.Merkmale............43 Montage./.Installation............43 Anwendungen..............44 Bestellangaben..............45.
  • Page 21: Warnung

    LICHE Drucktasten.oder.Potentiometer.des.Produktes.einstellen.bzw..bedienen.und. SPaNNuNG . Überbrückern.. die.mit.dem.Inhalt.dieses.Handbuches.vertraut.gemacht.wurden..Installation,.Montage.und.Demontage.von.Leitungen.. . Fehlersuche.im.Modul.. EMPFaNG uND auSPaCKEN: Packen.Sie.das.Modul.aus,.ohne.es.zu.beschädigen.und.sorgen.Sie.dafür,.dass. Reparaturen des Moduls und austausch von Sicherungen das.Handbuch.stets.in.der.Nähe.des.Moduls.und.zugänglich.ist... dürfen nur von PR electronics a/S vorgenommen werden. Die.Verpackung.sollte.beim.Modul.bleiben,.bis.dieses.am.endgültigen.Platz.. montiert.ist... Kontrollieren.Sie.beim.Empfang,.ob.der.Modultyp.Ihrer.Bestellung.entspricht.. WaRNuNG uMGEBuNGSBEDINGuNGEN: Das.System.5000.muss.auf.eine.DIN-Schiene.nach.DIN.46277. Direkte.Sonneneinstrahlung,.starke.Staubentwicklung.oder.Hitze,.mechanische. montiert.werden.. Erschütterungen.und.Stöße.sind.zu.vermeiden;.das.Modul.darf.nicht.Regen. Der.Verbindungsstecker.im.SYSTEM.5000.ist.an.
  • Page 22: Eg-Konformitätserklärung

    PR electronics a/S Sollten.Zweifel.bezüglich.der.richtigen.Handhabung.des.Moduls.bestehen,.sollte. Lerbakken 10 man.mit.dem.Händler.vor.Ort.Kontakt.aufnehmen..Sie.können.aber.auch.direkt. mit.PR electronics GmbH, Im Erlengrund 26, D-46149 Oberhausen, (Tel.: (0) DK-8410 Rønde 208 62 53 09-0).oder.mit.PR electronics a/S, Lerbakken 10, DK-8410 Rønde, hiermit.für.das.folgende.Produkt: Dänemark (Tel. : +45 86 37 26 77) Kontakt.aufnehmen.
  • Page 23: Zerlegung.des.systems.5000

    ZERLEGuNG DES SYSTEMS 5000 Ex-SPaNNuNGSVERSORGuNG PRepower 5420B Zunächst ist gefährliche Spannung von den anschlussklemmen zu trennen. •.2.Kanäle.. abbildung 1: •.5-Port.3,75.kVAC.galvanische.Isolation. Das.Modul.wird.von.der.DIN- Schiene.gelöst,.indem.man.den. •.Ausgangsspannung.>.18.V.für.Ex-Bereich. unteren.Verschluss.löst.. •.Gleichrichtung.von.aktiver.Stromschleife. •.Universelle.Versorgung.mit.AC.oder.DC Verwendung: •. Spannungsversorgung.mit.Sicherheitsbarriere.für.Geräte.in.explosionsgefähr- deten.Bereichen. •. Spannungsversorgung.mit.betriebssicherer.Gleichrichtung.der.aktiven. Stromschleife.von.2-Leiter-Signalgebern.in.explosionsgefährdeten.Bereichen. abbildung 2: Die.Platine.wird.daraufhin.heraus- Technische Merkmale: genommen,.indem.man.den.oberen. Verschluss.anhebt.und.gleichzeitig.
  • Page 24: Elektrische.daten

    2-Draht-Umformer Schleifen- alarm Versorg- Elektrische Daten: 2-Draht-Umformer umgebungstemperatur: -20°C.bis.+60°C Schleifen- alarm allgemeine Daten: Sicherung............400.mA.T./.250.VAC Isolationsspannung.Test/Betrieb....3,75.kVAC./.250.VAC Versorg- Kalibrierungstemperatur........ 20...28°C EMV-Immunitätseinwirkung........ <.±0,5% Erweiterte.EMV-Immunität:. NAMUR.NE.21,.A.Kriterium,.Burst..... <.±1% Leitungsquerschnitt.(max.)......1.x.2,5.mm .Litzendraht Klemmschraubenanzugsmoment....0,5.Nm Relative.Luftfeuchtigkeit.
  • Page 25 Eingang: Versorgungsspannung.universelles....21,6...253.VAC 50...60.Hz. 19,2...300.VDC Eigenverbrauch..........≤.2.W.(2.Kanäle) Stromverbrauch.Max........≤.4.W.(2.Kanäle) ausgänge: Ausgangsspannung........>.18.VDC.bei.20.mA Ausgangsstrom,.pro.Kanal.(Max.)....28.mA Relaisausgang: Innerhalb.Grenze.gezogen......>.3,8...<.20,5.mA Umax.............. 2 50.VRMS Imax..............2 .ARMS Max..AC-Leistung.......... 1 00.VA Max..Belastung.bei.24.VDC......1.A EEx- / I.S.-Zulassung: DEMKO.99ATEX126256........
  • Page 27 Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digitale France signalbehandlingsmoduler til industriel automation. Programmet PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, 4, allée des Sorbiers tel. +33 (0) 4 72 14 06 07 Universaltransmittere mfl.