Jøtul FS 73 Installation Instructions Manual page 42

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 38
ENGLISH
2. Fit the fireproof boards and make sure that the knockouts
are centred in relation to the outside air connection and
smoke outlet (rear outlet).
Outside air connection (optional)
If an outside air connection has been ordered, it should be
installed at this point. See the instruction manual for the outside
air connection (item no. 51046710)
4.2 Installation
Log store and base
Fig. 5
1. Centrally position the log store (A) approx. 120 mm in front
of the fireproof board (B).
Fig. 6
42
B
A
A
2. Apply acrylic adhesive along the front edge (A).
Fig. 7
3. Apply adhesive along the vertical edges (B) of the base (A).
Push the base against the fireproof board. It is important
to maintain the minimum allowable clearance of 70 mm
between the fireproof board and the wall (see Fig. 1).
Fig. 8
B
B
A