Page 2
About This User Guide Pls read all the content of the user guide carefully to use the products safely and effectively. You are advised of keeping it properly for your using reference for the next query. Disclaimer Please do not dismantle the product or tear up the seal on it, otherwise we won’t provide warranty or replacement service.
Page 3
Version record Manual Version number Version description publication date SV1.0 ZS_27 1.1_QRY_P1_20190925_20190 Initial version 2019-9-17 827e021_190827 第 3 页 共 70 页...
Catalog 1.Product Introduction ........................10 1.1 Main feature ........................... 10 1.2 Unpack your device ......................10 1.3 Communication port ......................10 1.4 Start-up, shutdown, standby and restart ................11 1.5 Maintenance ........................... 11 1.6 Reading skills .......................... 11 2. Barcode setting ..........................12 2.1 Mark Setting ...........................
Page 5
2.2.10 Control character escape ................... 18 2.2.11 GS Control character escape(need to turn on the control character escape function) ............................18 2.2.12 Prefix setting ........................18 2.2.13 Suffix setting ........................19 2.2.14 Unicode Output Mode ....................19 2.2.15 Inverse Code Option ...................... 20 2.2.16 Virtual keyboard ......................
Page 6
2.8 Keyboard layout setting ......................25 2.9 Symbologies ..........................28 2.9.1 enable/disable all symbologies ..................28 2.9.2 Codabar ..........................28 2.9.3 Codabar start/ending character setting ............... 28 2.9.4 Codabar limitation of length ..................29 2.9.5 Code 39 ..........................29 2.9.6 Code 39 check bit ......................29 2.9.7 Code 39 Full ASCII ......................
1D&2D barcodes by 2D image scanning pattern, and apply the complete set of patent technology developed by Guangzhou YOKO Electron Co., Ltd. The scanners above are of strong identification capability, and support automatic continuous scanning mode with fast and flexible scanning speed.
1.4 Start-up, shutdown, standby and restart Start-up:Connect host computer with scanner, which will automatically start-up and in working state. Shutdown:Remove the data cable which is connected with scanner; remove the USB which is connected with host computer; remove the power adapter which is inserted into RS-232 serial port.Restart:If the scanner crashes or doesn't respond, please switch it off and restart.
2. Barcode setting This model of laser desktop barcode scanner is designed to change settings by reading some special barcode, which we will give you a detailed introduction and show you all the barcodes for the corresponding setting in this section. The greatest advantage of this setting method is direct, intelligible and user friendly.
2.2.2 Restore factory default Restore Factory Default 2.2.3 Read version number Version Number 2.2.4 Product user configuration Scan the barcode below to save the current parameters of the product as a user configuration. Save User Configuration Scan the barcode below restores the product to a saved user configuration. Restore User Configuration 2.2.5 Upper PC and Notepad upload settings Upper PC Upload...
2.2.6 Interface mode setting The scanning platform supports the interface mode of USB keyboard, USB to serial port and serial port. Scan the barcode below to configure it as a USB PC keyboard and USB MAC keyboard mode. USB Keyboard USB MAC Keyboard (Disable) Host Mode (Command Decoding +...
Device ID Settings USB Upgrade 2.2.7 Wigan interface setting-- Wigan protocol format 26 bit 34 bit 2.2.8 Serial port setting 2.2.8.1 Serial port baud rate setting Baud Rate 4800 Baud Rate 9600 (Default ) Baud Rate 38400 Baud Rate 19200 第...
2.2.10 Control character escape Turn On Control Character Escape Turn Off Control Character Escape (Default) 2.2.11 GS Control character escape(need to turn on the control character escape function) Not Replace The output character "Ç" must Enable virtual keyboard first (mode1)”or(mode2)or(mode3) Replace With Ç...
Cancel prefix (Default) <STX> <Data> 2.2.13 Suffix setting Cancel Suffix <Data> <CR (Carriage Return)> <Data> <LF> <Data> <CR> <LF> (Default) <Data> <\t> <Data> <ETX> 2.2.14 Unicode Output Mode In order to correctly output according to the specified encoding format, the output encoding format needs to be specified,for example, simplified Chinese is configured as GBK encoding in notepad /excel output, and UNICODE encoding in Word output.
keyboard is forced to be virtual keyboard output. English Output ( Default ) Unicode Output (Notepad/ Excel) UNICODE Coding (Word ) 2.2.15 Inverse Code Option (Only 1D/DataMatrix/Aztec) Only Decode Normal Code Only Decode Inverse Code Decode Both Normal Code And Inverse Code(Default) 式...
Good Read Beep Off( Default) 2.3.4 Beep pitch-good read Low Pitch (Default ) Middle Pitch High Pitch 2.3.5 Beep duration-good read Tone Long (Default ) Tone Pip 2.3.6 Error sound You will hear 4 continue alarm sounds when data upload failure, one single alarm sound means scan indistinguishableness barcode.
Error Sound High Pitch 2.3.7 Good-read LED Good-Read LED Off Good-Read LED On( Default) 2.4 Timeout between decodes (Same barcodes)(Self-induction mode) 2.4.1 Timeout between same decode Used to configure the interval time for solving the same barcode. If the setting time is not exceeded, the same barcode will be solved only once.
2.4.2 Reading time Single Reading Time In the inductive reading mode, this parameter refers to the maximum length of time that the reading engine is allowed to continue to collect and recognize before the reading is successful. After a successful reading or a single reading timeout, the reading engine will enter an interval that does not capture the reading.
2.6 OA & LF Setting(USB keyboard) Only 0A(LF) Line Feed Only 0D(CR) Line Feed (Default) Both 0A(LR) And 0D(CR) Line Feed 2.7 USB keyboard text-transform Normal Output (Default) Case Reversal All Caps All Lowercase 2.8 Keyboard layout setting English (United States) 第...
Page 26
French (France) Italian (Italy) Italian 142 (Italy)(Disable) German (Germany) Spanish (Spain) Spanish (Latin America)(Disable) Finnish(Disable) Japanese(Disable) Russian (MS)(Disable) Russian (typewriter)(Disable) 第 26 页 共 70 页...
Greek (MS)(Disable) French (Belgium) English (UK)(Disable) 2.9 Symbologies 2.9.1 enable/disable all symbologies Enable all barcode might slow down scanner decode speed. We suggest enable the barcode you need based on your scene. Enable all barcode is default . Enable All Symbologies (Default) Disable All Symbologies 2.9.2 Codabar Enable Codabar...
ITF25 16 bit Length ITF25 18 bit Length ITF25 20 bit Length ITF25 22 bit Length ITF25 24bit Length 2.9.13 Interleaved 2 of 5 Limitation of length Interleaved 2 of 5 Min Limitation Length (4~128 Bit) Interleaved 2 of 5 Max Limitation Length (4~128 Bit) 2.9.14 Industrial 2 of 5 (Industrial 25code)(4-24bit)...
2.9.15 Industrial 2 of 5 Limitation of length Industrial 2 of 5 Min Length (4~128 bit) Industrial 2 of 5 Max Length (4~128 bit) 2.9.16 Matrix 2 of 5 (matrix 25 code)(4-24 bit) Enable Matrix 2 of 5 Disable Matrix 2 of 5 2.9.17 Matrix 2 of 5 Limitation of length Matrix 2 of 5 Min Length (4~128 bit) Matrix 2 of 5 Max Length (4~128 bit)
2.9.19 Standard 25Limitation of length Standard 25 Min Length(4~128 bit) Standard 25 Max Length (4~128 Bit) 2.9.20 Standard 25 check bit setting Standard 25 Don’t Check (Default) Standard 25 Check Not Output Standard 25 Check And Output 2.9.21 Code 93 Enable Code 93 Disable Code 93 2.9.22 Code 93 Limitation of length...
Disable PDF417 2.9.55 Micro PDF417 Enable Micro PDF417 Disable Micro PDF417 2.9.56 QR Code Enable QR Disable QR 2.9.57 Micro QR Enable Micro QR Disnable Micro QR 2.9.58 Data Matrix Enable Data Matrix Disable Data Matrix 第 43 页 共 70 页...
(Please follow the barcode type ID table and data and edit barcode in the appendix after scanning) 2.12 Barcode prefix&suffix order selection Prefix <Prefix><CODE ID><AIM ID><User-Defined Prefix>(Default) <Prefix><User-Defined Prefix><CODE ID><AIM ID> Suffix <User-Defined Suffix><CODE ID><AIM ID><Suffix> (Default) <CODE ID><AIM ID><User-Defined Suffix><Suffix> 2.13 Code ID setting Output options Disable CODE ID (Default)
(Please follow the barcode type ID table and data and edit barcode in the appendix after scanning) Clear All User-Defined CODE ID 2.14 AIM ID Setting Disable Barcode AIM ID (Default) Enable Former Barcode AIM ID Enable Latter Barcode AIM ID 第...
Appendix 5 Default setting table Parameter name Default setting Remarks Communication settings Serial port baud rate 9600 Serial check bit No check bit TTL-232 Serial data bit 8 bit (default) Serial port stop 1 bit Host mode USB Keyboard layout American keyboard Barcode content contains carriage 0D only (enter character...
Page 58
Lighting mode Normal mode Aiming mode Normal mode Prompt output Power on tone prompt Beep type audio rate low Decoding success Beep volume high tone Beep duration long code read tone setting Allow Decoding success LED prompt Data editing Prefix and suffix Prefix adding No add Prefix content...
Page 59
Barcode symbol parameter Inverted barcode reading Open Valid for all bar code symbol types Code 128 Reading Allow Max length Min length GS1-128(UCC/EAN-128) Reading Allow Max length Min length EAN-8 Reading Allow EAN-13 Reading Allow 2 bit extension code No reading 5 bit extension code No reading must have the extension code...
Page 60
ISBN Reading Not allow UPC-E Reading allow Output check character Output Expand to UPC-A No expand UPC-A Reading allow Output check character Output UPC-A to EAN-13 Interleaved 2 of Reading allow Check No check Max length Min length Matrix 2 of 5 Read Not allow Max length...
Page 61
Reading allow Max length Min length Standard 2 of 5 Reading allow Check No check Output check character No output Max length Min length Code 39 Reading allow Check No check Output check character No output Default (off) Support Full ASCII Support Max length Min length...
Page 62
Check No check No output Send start character and end character Max length Min length Code 93 Reading allow Max length Min length GS1 Databar(RSS14)(Stacked) Reading allow send AI(01) character Send GS1 Databar Limited Reading allow Send AI(01) character Send GS1 Databar Expanded reading allow...
Page 63
Max length Min length Plessey reading Allow Check but don’t Check bit output Max length Min length MSI-Plessey Reading allow Output check Don’t output Check bit mode selection 1 bit MOD10 Max length Min length PDF417 Reading allow Max length 2710 Min length Micro PDF417...
Page 64
2710 Max length Min length QR Code Reading allow Max length 7089 Min length Micro QR Reading allow Max length 7089 Min length Data Matrix Reading allow Max length 3116 Min length 第 64 页 共 70 页...
Appendix 6 Operational character (USB keyboard) No escape Escape corresponding character hexadecimal corresponding function key combination control key (Null char.) Null Ctrl+2 (Start of Header) Keypad Enter Ctrl+A (Start of Text) Caps Lock Ctrl+B (End of Text) Null Ctrl+C (End of Transmission) Null Ctrl+D (Enquiry)
Page 66
(XOFF) (Device Control 3) 13 Delete Ctrl+S (Device Control 4) tab+shift Ctrl+T (Negative Ctrl+U Acknowledgement) (Synchronous Idle) Ctrl+V (End of Trans. Block) Ctrl+W (Cancel) Ctrl+X (End of Medium) Ctrl+Y (Substitute) Ctrl+Z (Escape) Ctrl+[ (File Separator) Ctrl+\ 参见下表 Ctrl+] (Group Separator) (Request to Send) Ctrl+6 (Unit Separator)
Some feature configuration instructions and examples Example of custom prefix and suffix configuration Configure the barcode pre/suffix by scan code. Each prefix or suffix character can be up to 10.(To ensure that custom suffixes can be output, configure the scanner's custom pre/post suffix output option to be turned on.) Example 1.1: Add a custom prefix XYZ to all types of barcode.
Example 1.2:Add a custom prefix R to the QR code Query the appendix barcode type ID table,the HEX value of all code systems is 51.Query the visible character ASCII table,the HEX value corresponding to R is 58, 59, 5A. Scan the configuration code Customize The Prefix, then scan the appendix data and edit the 5, 1, 5, 2 in the barcode to save, that is, complete the configuration.
Page 70
1, 2, and save the barcode to complete the configuration. Example 2.2:Configure Interleaved 2 of 5 barcode length to 14 bits Configuring 14 bits of Interleaved 2 of 5 barcode length can scan directly and configure ITF25 14 bits of barcode lengths for configuration.It can also be configured by the maximum and minimum length of the barcode: Scan configuration code Interleaved 2 of 5 minimum length limit,then scan the appendix data and edit the 1, 4 in the bar code, save.