Page 1
User Guide This User Guide Applies to E1007...
Page 2
About This User Guide Pls read all the content of the user guide carefully to use the products safely and effectively. You are advised of keeping it properly for your using reference. Disclaimer Please do not dismantle the product or tear up the seal on it, otherwise we won’t provide warranty or replacement service.
Page 3
Version Record Version number Version description Version date V 1.0.0 Initial version 2016-8-23 V 1.2.3 Optimize menu 2016-9-10 V 1.5.1 Optimize decoding performance 2016-12-01 V 2.0.1 Modify performance menu 2017-03-01 V 2.0.2 Perfect overall performance 2017-07-18...
1、Product Introduction This user guide applies to E1005 and E1007, which identify 1D barcodes by red light scanning pattern, and apply the complete set of patent technology developed by Guangzhou YOKO Electron Co., Ltd. The scanners above are of strong identification capability, and support automatic continuous scanning mode with fast and flexible scanning speed.
1.3 Product display 1.3.1 External view 1.3.2 Dimention(mm) Side view Aerial view 1.4 Communication port The scanner must be connected to a host to operate. Host can be a PC, POS machine, intelligent terminal with USB or RS-232 interface. USB interface on host RS-232 RS-232 interface on host 1.5 Interface description...
interfaces can be customized according to customer needs. 1.5.1 Scan module interface CMOS Interface NO. Name Type Description Empty Spare DC power DC3.3V or DC5V(depending on the supply module)± 5% Digital ground Input Serial input port TTL level output Serial input port TTL level USB_D- Input / output USB_D- signal USB_D...
Page 10
According to the actual situation can be divided into two types: usb hid keyboard and usb virtual serial port. When you connect the engine to the host via USB, you can enable the USB HID-KBW feature by scanning the bar code below; then the engine's transfer will be modeled as a USB keyboard input.
1.6 Connect your device 1.6.1 Connect with USB 1: Connect the device interface of USB with scanner ; 3: Connect the host interface (USB interface) of USB with host computer. 1.6.2 Connect with RS-232 Serial Port 1: Connect the device interface of RS-232 serial port with scanner ;...
1、 "√" represents the default parameter is open, "-" denotes the default parameter is close, "X" means this parameter does not exist in the barcode type; 2、 "2" marked on the upper right corner of minimum / maximum length means bar length is fixed;...
2.Command Instruction 2.1 barcode instructions explain 1、Instruction barcodes use code 39 type Full-ASCII codes to design and print. The Command value in instruction barcodes is the same as serial port instructions. 2、The description with an asterisk(*)means factory default。 (1)Scan: Enter setting “YSET”. After enter setting, if you don’t scan any instruction barcodes in 30 seconds, the scanner will exit setting automatically.
2.2 Serial port instructions explain Table 2.2-1 Data format of serial port instructions Message Message Length Reserve Reserve Command beeper Check Sum Source target Table 2.2-2 Serial port instructions analysis Field Format Sub-Field Description command length, not include Length 1 Byte Length Check Sum,...
2.3 Instruction list Table 2.3-1 instruction list instruction Serial port Serial port name describe barcodes instructions reply √ YSET Enter setting mode × × √ √ √ YEND Exit and save √ TRIGGER_SCAN Trigger scan × √+barcode √ √ √ STOP_SCAN Stop scanning √...
2.4 Quick instructions(HEX format) quick instructions must be used in below conditions: Message Source = 0x04(PC or IPC) ; = 0x31(Barcode scanner 0x31 ) ; Message target Beeper = 0xFF(close) 。 quick instructions for PC or IPC to barcode scanner: Table 2.4-1 Host to Decoder function instructions(HEX format)...
3、System setting Option and function setting mainly through reading a series of special barcodes. In this chapter, we will provide you a detailed introduction of the options and functions available for user setting, and the corresponding setup code. This method of setting the scanning is direct, easy to understand and user friendly. 3.1 Mark setting Enter setting 3.2 Setting Steps...
Setting user defaults (Save current setting as user-defined defaults) Read production batch version Read BOOTLOAD version 3.2.1 Interface mode setting RS 232 MODEL USBMODEL 3.2.2 Buzzer and LED setting Shut down start voice Open start voice(default) Successful scanning sound off Successful scanning sound on(default) Buzze Volume low Buzze Volume middle(default)...
900ms 1000ms 1500ms 2000ms 4000ms(default) 6000ms 9900ms 3.2.10 Case switching No case switching(default) Lowercase switch to uppercase Uppercase switch to lowercase 3.2.11 auto sense mode setting Disable(default) 第 18 页 共 36 页...
3.2.15 Start character No start character(default) Space + barcode ID+barcode ID+ user-defined start character + barcode user-defined start character + ID + barcode user-defined start character + barcode 3.2.16 Ending character setting No ending character(default) 0x0D as ending character 第 21 页 共 35 页...
Page 28
0x0A as ending character 0x0D 0x0A as ending character Tab(0x09) Tab(0x09) 0x0D Barcode + user-defined ending character Barcode + user-defined ending character+0x0D Barcode + user-defined ending character+0x0A Barcode + user-defined ending character+0x0D 0x0A Barcode + user-defined ending character + Tab(0x09) 第...
Page 38
YS90 YS91 Arrow Down YS92 Arrow up YS93 Arrow right YS94 Arrow left YS95 Insert YS96 Home YS97 YS98 Page up YS99 Page down YS9A Left Shift YS9B Left Ctrl YS9C Left Alt YS9D Left GUI YS9E Right Shift YS9F Right Ctrl YSA0 Right Alt...
Appendix 2 ASCII table Decimal Octal Hexadecimal character description start of header start of text end of text end of transmission enquiry acknowledge bell backspace horizontal tab line feed vertical tab form feed carriage return shift out shift in data link escape no assignment,but usually XON no assignment,but usually XOFF negative acknowledge...
Page up Page down Left Shift Left Ctrl Left Alt Left GUI Right Shift Right Ctrl Right Alt Right GUI Caps Lock Appendix 3 barcode sample name Barcode sample remarks EAN13 UPC-A EAN8 Default data: 1234565 UPC-E Codabar Encoded data: c01235d Code93 Code39(Regular) Code 39(FullASCII)