Advertisement

Quick Links

User Guide
This User Guide Applies to E1007

Advertisement

Table of Contents
loading

Summary of Contents for YOKO E1007

  • Page 1 User Guide This User Guide Applies to E1007...
  • Page 2 About This User Guide Pls read all the content of the user guide carefully to use the products safely and effectively. You are advised of keeping it properly for your using reference. Disclaimer Please do not dismantle the product or tear up the seal on it, otherwise we won’t provide warranty or replacement service.
  • Page 3 Version Record Version number Version description Version date V 1.0.0 Initial version 2016-8-23 V 1.2.3 Optimize menu 2016-9-10 V 1.5.1 Optimize decoding performance 2016-12-01 V 2.0.1 Modify performance menu 2017-03-01 V 2.0.2 Perfect overall performance 2017-07-18...
  • Page 5: Table Of Contents

    CATALOG 1、Product Introduction ............................1 1.1 Main feature ..............................1 1.2 Unpack your device ............................ 1 1.3.1 External view ......................错误!未定义书签。 1.4 Communication port ........................... 2 1.5 Interface description ........................... 2 1.5.1 Scan module interface CMOS ....................... 3 1.5.2 Standard serial port(DB9) ......................3 1.5.3 USB interface ...........................
  • Page 6 3、System setting ..............................12 3.1 Mark setting ............................... 12 3.2 Setting Steps ............................. 12 3.2.1 Interface mode setting ........................13 3.2.2 Buzzer and LED setting ....................... 13 3.2.3 Baud rate setting ........................... 14 3.2.4 Serial port instructions response setting ..................14 3.2.5 Trigger scan and stop scan setting .....................
  • Page 7: 1、Product Introduction

    1、Product Introduction This user guide applies to E1005 and E1007, which identify 1D barcodes by red light scanning pattern, and apply the complete set of patent technology developed by Guangzhou YOKO Electron Co., Ltd. The scanners above are of strong identification capability, and support automatic continuous scanning mode with fast and flexible scanning speed.
  • Page 8: External View

    1.3 Product display 1.3.1 External view 1.3.2 Dimention(mm) Side view Aerial view 1.4 Communication port The scanner must be connected to a host to operate. Host can be a PC, POS machine, intelligent terminal with USB or RS-232 interface. USB interface on host RS-232 RS-232 interface on host 1.5 Interface description...
  • Page 9: Scan Module Interface Cmos

    interfaces can be customized according to customer needs. 1.5.1 Scan module interface CMOS Interface NO. Name Type Description Empty Spare DC power DC3.3V or DC5V(depending on the supply module)± 5% Digital ground Input Serial input port TTL level output Serial input port TTL level USB_D- Input / output USB_D- signal USB_D...
  • Page 10 According to the actual situation can be divided into two types: usb hid keyboard and usb virtual serial port. When you connect the engine to the host via USB, you can enable the USB HID-KBW feature by scanning the bar code below; then the engine's transfer will be modeled as a USB keyboard input.
  • Page 11: Connect Your Device

    1.6 Connect your device 1.6.1 Connect with USB 1: Connect the device interface of USB with scanner ; 3: Connect the host interface (USB interface) of USB with host computer. 1.6.2 Connect with RS-232 Serial Port 1: Connect the device interface of RS-232 serial port with scanner ;...
  • Page 12: Start-Up, Shutdown And Restart

    1、 "√" represents the default parameter is open, "-" denotes the default parameter is close, "X" means this parameter does not exist in the barcode type; 2、 "2" marked on the upper right corner of minimum / maximum length means bar length is fixed;...
  • Page 13 Barcode scanning example: 第 7 页 共 35 页...
  • Page 14: Command Instruction

    2.Command Instruction 2.1 barcode instructions explain 1、Instruction barcodes use code 39 type Full-ASCII codes to design and print. The Command value in instruction barcodes is the same as serial port instructions. 2、The description with an asterisk(*)means factory default。 (1)Scan: Enter setting “YSET”. After enter setting, if you don’t scan any instruction barcodes in 30 seconds, the scanner will exit setting automatically.
  • Page 15: Serial Port Instructions Explain

    2.2 Serial port instructions explain Table 2.2-1 Data format of serial port instructions Message Message Length Reserve Reserve Command beeper Check Sum Source target Table 2.2-2 Serial port instructions analysis Field Format Sub-Field Description command length, not include Length 1 Byte Length Check Sum,...
  • Page 16: Instruction List

    2.3 Instruction list Table 2.3-1 instruction list instruction Serial port Serial port name describe barcodes instructions reply √ YSET Enter setting mode × × √ √ √ YEND Exit and save √ TRIGGER_SCAN Trigger scan × √+barcode √ √ √ STOP_SCAN Stop scanning √...
  • Page 17: Quick Instructions(Hex Format

    2.4 Quick instructions(HEX format) quick instructions must be used in below conditions: Message Source = 0x04(PC or IPC) ; = 0x31(Barcode scanner 0x31 ) ; Message target Beeper = 0xFF(close) 。 quick instructions for PC or IPC to barcode scanner: Table 2.4-1 Host to Decoder function instructions(HEX format)...
  • Page 18: 3、System Setting

    3、System setting Option and function setting mainly through reading a series of special barcodes. In this chapter, we will provide you a detailed introduction of the options and functions available for user setting, and the corresponding setup code. This method of setting the scanning is direct, easy to understand and user friendly. 3.1 Mark setting Enter setting 3.2 Setting Steps...
  • Page 19: Interface Mode Setting

    Setting user defaults (Save current setting as user-defined defaults) Read production batch version Read BOOTLOAD version 3.2.1 Interface mode setting RS 232 MODEL USBMODEL 3.2.2 Buzzer and LED setting Shut down start voice Open start voice(default) Successful scanning sound off Successful scanning sound on(default) Buzze Volume low Buzze Volume middle(default)...
  • Page 20: Baud Rate Setting

    Volume high Successful setting sound off Successful setting sound on(default) 3.2.3 Baud rate setting 2400 baud 4800 baud 9600 baud(default) 19200 baud 38400 baud 57600 baud 115200 baud 3.2.4 Serial port instructions response setting NO response(default) 第 14 页 共 36 页...
  • Page 21: Trigger Scan And Stop Scan Setting

    response 3.2.5 Trigger scan and stop scan setting Trigger scan Stop scan 3.2.6 Trigger scan model and reading mode setting Single trigger scan model(default) Continue scan model Not allowed Repeat reading allowed Repeat reading(default) Enable/disable allowed Repeat reading 第 15 页 共 35 页...
  • Page 22: Same Barcode Scanning Interval Setting

    3.2.7 Same Barcode Scanning Interval setting 0ms(default) 100ms 200ms 500ms 900ms 1000ms 1500ms 2000ms 9900ms 3.2.8 Scan time setting for key trigger scan mode 0ms(default) 100ms 200ms 第 16 页 共 36 页...
  • Page 23: Scan Time Setting For Serial Command/Auto Scan Mode

    500ms 900ms 1000ms 1500ms 2000ms 4000ms 6000ms 9900ms 3.2.9 Scan time setting for serial command/auto scan mode 100ms 200ms 500ms 第 17 页 共 35 页...
  • Page 24: Case Switching

    900ms 1000ms 1500ms 2000ms 4000ms(default) 6000ms 9900ms 3.2.10 Case switching No case switching(default) Lowercase switch to uppercase Uppercase switch to lowercase 3.2.11 auto sense mode setting Disable(default) 第 18 页 共 36 页...
  • Page 25: Usb Upload Speed Setting

    Enable high sensitivity(default) low sensitivity 3.2.12 USB upload speed setting USB upload speed slow(default) USB upload speed middle USB upload speed fast 3.2.13 Decode setting Disable Read(EAN) Enable Read(EAN) (default) Disable Read(Codabar) Enable Read(Codabar) (default) Disable Read(Code 93) 第 19 页 共 35 页...
  • Page 26: Disable/Enable Read All Barcodes

    Enable Read(Code 93) (default) Disable Read(Code 128) Enable Read(Code 128) (default) Disable Read(Code 25) Enable Read(Code 25) (default) 3.2.14 Disable/Enable read all barcodes Disable Read All Barcodes Enable Read All Barcodes 第 20 页 共 36 页...
  • Page 27: Start Character

    3.2.15 Start character No start character(default) Space + barcode ID+barcode ID+ user-defined start character + barcode user-defined start character + ID + barcode user-defined start character + barcode 3.2.16 Ending character setting No ending character(default) 0x0D as ending character 第 21 页 共 35 页...
  • Page 28 0x0A as ending character 0x0D 0x0A as ending character Tab(0x09) Tab(0x09) 0x0D Barcode + user-defined ending character Barcode + user-defined ending character+0x0D Barcode + user-defined ending character+0x0A Barcode + user-defined ending character+0x0D 0x0A Barcode + user-defined ending character + Tab(0x09) 第...
  • Page 29: User-Defined Start Character/Ending Character

    3.2.17 User-defined start character/ending character User-defined start character User-defined ending character remark: User-defined start character/ending character please refer to appendix 1 第 23 页 共 35 页...
  • Page 30: Appendix 1 User-Defined Start Character/Ending Character

    Appendix Appendix 1 User-defined start character/ending character Control character barcode ^@(NULL) YS00 ^A(SOH) YS01 ^B(STX) YS02 ^C(ETX) YS03 ^D(EOT) YS04 ^E(ENQ) YS05 ^F(ACK) YS06 ^G(BEL) YS07 YS08 ^H(BS) YS09 ^I(HTab) ^J(LF) YS0A ^K(VTab) YS0B ^L(FF) YS0C ^M(CR) YS0D ^N(SO) YS0E ^O(SI)...
  • Page 31 ^P(DLE) YS10 ^Q(DC1) YS11 ^R(DC2) YS12 ^S(DC3) YS13 ^T(DC4) YS14 ^U(NAK) YS15 ^V(SYN) YS16 ^W(ETB) YS17 ^X(CAN) YS18 ^Y(EM) YS19 ^Z(SUB) YS1A ^[(ESC) YS1B ^\(FS) YS1C ^](GS) YS1D ^^(RS) YS1E ^_(US) YS1F YS20 第 25 页 共 35 页...
  • Page 32 character barcode YS21 " YS22 YS23 YS24 YS25 & YS26 YS27 YS28 YS29 YS2A YS2B YS2C YS2D YS2E YS2F YS30 YS31 YS32 第 26 页 共 36 页...
  • Page 33 YS33 YS34 YS35 YS36 YS37 YS38 YS39 YS3A YS3B < YS3C YS3D > YS3E YS3F YS40 YS41 YS42 YS43 YS44 YS45 YS46 第 27 页 共 35 页...
  • Page 34 YS47 YS48 YS49 YS4A YS4B YS4C YS4D YS4E YS4F YS50 YS51 YS52 YS53 YS54 YS55 YS56 YS57 YS58 YS59 YS5A 第 28 页 共 36 页...
  • Page 35 YS5B YS5C YS5D YS5E YS5F YS60 YS61 YS62 YS63 YS64 YS65 YS66 YS67 YS68 YS69 YS6A YS6B YS6C YS6D YS6E 第 29 页 共 35 页...
  • Page 36 YS6F YS70 YS71 YS72 YS73 YS74 YS75 YS76 YS77 YS78 YS79 YS7A YS7B YS7C YS7D YS7E YS7F 第 30 页 共 36 页...
  • Page 37 barcode Function keys YS80 YS81 YS82 YS83 YS84 YS85 YS86 YS87 YS88 YS89 YS8A YS8B YS8C Backspace YS8D YS8E Return(ENTER) YS8F Enter(Numeric Keypad) 第 31 页 共 35 页...
  • Page 38 YS90 YS91 Arrow Down YS92 Arrow up YS93 Arrow right YS94 Arrow left YS95 Insert YS96 Home YS97 YS98 Page up YS99 Page down YS9A Left Shift YS9B Left Ctrl YS9C Left Alt YS9D Left GUI YS9E Right Shift YS9F Right Ctrl YSA0 Right Alt...
  • Page 39: Appendix 2 Ascii Table

    Appendix 2 ASCII table Decimal Octal Hexadecimal character description start of header start of text end of text end of transmission enquiry acknowledge bell backspace horizontal tab line feed vertical tab form feed carriage return shift out shift in data link escape no assignment,but usually XON no assignment,but usually XOFF negative acknowledge...
  • Page 40 & < > 第 34 页 共 36 页...
  • Page 41 第 35 页 共 35 页...
  • Page 42 delete Backspace Return Enter Arrow Down Arrow up Arrow right Arrow left Insert Home 第 36 页 共 36 页...
  • Page 43: Appendix 3 Barcode Sample

    Page up Page down Left Shift Left Ctrl Left Alt Left GUI Right Shift Right Ctrl Right Alt Right GUI Caps Lock Appendix 3 barcode sample name Barcode sample remarks EAN13 UPC-A EAN8 Default data: 1234565 UPC-E Codabar Encoded data: c01235d Code93 Code39(Regular) Code 39(FullASCII)
  • Page 44 第 38 页 共 36 页...
  • Page 45 第 39 页 共 35 页...

This manual is also suitable for:

E1005

Table of Contents