Page 1
User Guide This User Guide Applies to EP3000, EP5000 第 1 页 共 45 页...
Page 2
About This User Guide Pls read all the content of the user guide carefully to use the products safely and effectively. You are advised of keeping it properly for your using reference. Disclaimer Please do not dismantle the product or tear up the seal on it, otherwise we won’t provide warranty or replacement service.
1、Product Introduction This user guide applies to EP3000 and EP5000, which identify 1D&2D barcodes by 2D image scanning pattern. The scanners above are of strong identification capability, and support automatic continuous scanning mode with fast and flexible scanning speed. In this chapter, we will introduce the instruction of scanner with pictures, please compare to the scanner you bought when reading this user guide, which is good for your understanding.
EP5000 1.4 Communication port The scanner must be connected to a host to operate. Host can be a PC, POS machine, intelligent terminal with USB、TTL、RS232、RS485 or Wiegand interface. 第 3 页 共 22 页...
Page 9
Signal Name Note Number USB_D- USB bus minus - disable - disable Ground cathode voltage - disable USB bus plus USB_D+ USBVBUS USB voltage +5V anode voltage TXD-Wiegan 3.3V TTL、RS232、RS485A+、Wiegand 1 - disable 3.3V TTL compatible with 5V input、RS232、 RXD-Wiegan RS485B-、Wiegand 0 USB interface on host RS-232...
1.5 Start-up, shutdown, standby and restart Start-up:Connect host computer with scanner, which will automatically start-up and in working state. Shutdown:Remove the data cable which is connected with scanner; remove the USB which is connected with host computer; remove the power adapter which is inserted into RS-232 serial port.
2、Barcode Menu This model of laser desktop barcode scanner is designed to change settings by reading some special barcode, which we will give you a detailed introduction and show you all the barcodes for the corresponding setting in this section. The greatest advantage of this setting method is direct, intelligible and user friendly.
product batch version 2.2.4 Read user defaults Save the current menu settings as user-defined menu settings W rite user defaults You can restore the menu settings for the user-defined menu settings. Restore user defaults 2.2.5 working mode 1(auto sense + USB keyboard/physical serial port)...
8 data bits,2 stop bits,odd-parity check 2.2.9 Character escape Enable characte r esc ape Disable cha rac ter escape ( default) 2.10 Code ID output Disable CODE ID(default) Enable CODE ID before barcode Enable CODE ID after barcode edit User-defined CODE ID (After scan this code you can set the prefix you want based on the data and barcode in table ID)...
Add ETX 2.2.14 Chinese output mode English output(default) Chinese output(TXT/excel) Chinese output(Word) 2.2.15 invoice (For China) Disable invoice code(default) Enable invoice code In order to make sure the invoice output correctly, when you use invoice function please set Chinese output to “Chinese output(TXT/excel)”。 2.2.16 invoice type (for China) Special invoice(default)...
Only decode inverse code Decode both normal code and inverse code 2.3 virtual keyboard Mode 1: The characters between 0x20 and 0xFF do not support the virtual keyboard mode output under the current keyboard layout. The characters between 0x00 and 0x1F are output according to the control characters (see Appendix).
LINUX 2.4 Beeper and LED notifications 2.4.1 Beeper Volume setting Volume low Vol ume high( default) 2.4.2 startup beep Shut do wn s tartup be ep Open sta rtup be ep( default) 2.4.3 good read beep good read beep good read beep off ( default) 2.4.4 Beep pitch-good read Low pitch Middle pitch (...
High pitch 2.4.5 beep duration-good read Tone long( default) Tone pip 2.4.6 error sound You will hear 4 contin ue alarm sounds whe n data upload failure , one single alarm sound means scan indistinguishableness b arcode. Alarm sound low pitch ( default) Alarm sound middle pitch Alarm sound high pitch 2.4.7 good-read LED...
Normal mode LED always off LED alwa ys on Timeout between decodes 2.5.1 Timeout between decodes (Same barcodes) By default, the interval time between first scanning and second scanning for same barcode is 200ms. To avoid being repeatedly with a barcode, you can set the scan interval. 500ms 750ms(default)...
800ms 2.6 USB keyboard setting 2.6.1 USB keyboard update speed setting The barcode is used to set the update speed when scanner is in USB keyboard pattern. If the performance of your PC is lower, we suggest you choose slow update speed to make sure the scanner update the right data.
Only 0A(LF) line feed Only 0D(CR)line feed(default) Both 0A(LR) and 0D(CR) line feed 2.6.3 USB keyboard text-transform Normal output(default) Case reversal all Caps All lower case 2.7 Keyboard layout setting English (United States) French (France) Italian (Italy) 第 18 页 共 27页...
Page 24
Italian 142 (Italy) German (Germany) Spanish (Spain) Spanish (Latin America) Greek (MS) Finnish Japanese Russian (MS) Russian (typewriter) Arabic (101) Irish Polish (214) 第 19 页 共 27页...
2.8.1 enable/disable all symbologies Enable all barcode might slo w do wn scann er decode speed. W e suggest enable the ba rc ode you need based on your scene . Enable all barcode is default Enable all symbologies Disable all symbologies 2.8.2 Codabar Enable Codabar Disable Codabar...
ITF25 Fixed Length of 18 Digits ITF25 Fixed Length of 20 Digits ITF25 Fixed Length of 22 Digits ITF25 Fixed Length of 24 Digits 2.8.13 Industrial 2 of 5 Limitation of length Interleaved 2 of 5 min length (0~50 bits) Interleaved 2 of 5 max length(0~50 bits)...
Configuration Code Turn on configuration instruction and example Barcode length limit configuration example When configuring the minimum barcode length limit, you must ensure that the minimum length of the configuration is not greater than the current maximum length configuration. Otherwise, an error will be displayed.