Section 5: Reporting Formats; + 2" Standard; Ademco Contact Id - Honeywell NOTIFIER UDACT-2 Instruction Manual

Universal digital alarm communicator
Table of Contents

Advertisement

The formats sent by the UDACT-2 to the Central Station are set out in this section. Event codes are defined for each protocol.
Use Ademco Contact ID for specific zone or point identification.
Pulsed formats typically require 15 to 20 seconds for message transmission.
Refer to Section 6.1, "Compatible UL Listed Receivers", on page 33 for a list of compatible receivers.

5.1 "4 + 2" Standard

Standard "4 + 2" reporting consists of the following format:
XXXX EE
XXXX = 4-digit Customer Account Code.
EE = Event Code Refer to Table 5.1 for code definitions.
The table below shows the data reporting format for the "4+2 Standard" pulsed format.

5.2 Ademco Contact ID

Ademco Contact ID reporting consists of the following format:
SSSS 18 QXYZ GG CCC
SSSS = 4-digit Customer Account Code.
18 = Identifies transmission as Ademco contact ID to the receiver at the Central Station.
Q = Event Qualifier
• 1 = New Event
29

Section 5: Reporting Formats

Data Description
General Alarm
Zone/point alarm code
General Supervisory
Zone/point supervisory code
General Fault
AC Fault
Zone/point fault code
Low Battery fault
Telco Primary Line Fault
Telco Secondary Line Fault
NAC Fault
Communication Trouble Primary #
Communication Trouble Secondary #
485 Communication Trouble
System Off Normal
Reserved
Reserved
Reserved
Reserved
Security alarm
General Alarm restore
Zone/point alarm restore
General Supervisory restore
Zone/point supervisory restore
General Fault Restore
AC Fault Restore
Zone/point fault restore
Low Battery Fault Restore
Telco Primary Line Fault Restore
Telco Secondary Line Fault Restore
NAC Fault Restore
Communication Trouble Primary Number Restore
Communication Trouble Secondary Number Restore
485 Communication trouble restore
System Off Normal Restore
Reserved
System 24 Hour Test
System 24 Hour Test with Active Event
Manual Test
Security alarm Restore
Note: Zero event entries prevent the transmission of the report to the Central Station.
Table 5.1 4+2 Standard Data Reporting Format
Data Reporting Format
4-digit Customer
Account Code
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
UDACT-2 — Instruction Manual P/N 54089:B3 10/29/2019
Event
Code
11
00
81
00
F1
F6
00
F8
FA
FB
FC
FD
FE
FE
FF
00
00
00
00
11
E1
00
E2
00
E3
E6
00
E8
EA
EB
EC
ED
EE
EE
EF
00
99
91
92
E1