3
Select configuration method
The Click 112/114 can be configured in three ways: DIP switches, the front panel menu and Click Super-
visor. These three different configuration methods can configure different sets of options; some of these
parameters can be set using multiple configuration methods, and some of them can only be set using one
Baud Rate
Channel Input Map
Autobaud
Reset to Default
Description
Location
Device ID
To use this
configuration method:
4
Configuration option 1: DIP switches
The DIP switches on the circuit board can be used to change input mapping and the baud rates used for bus
1 and bus 2. These parameters can also be changed using the two other configuration options.
Note. For each parameter, if any of the switches are turned on, that parameter is in Hardware mode. If
Hardware mode is selected, the parameter can only be configured using the switches.
Look at the figure below to see how to set the switches in order to configure the parameter. To turn a switch
on, flip it up.
Channel Input Mapping
This function lets you map two (Click
112) or four (Click 114) of the input data
channels coming from the sensor to the
output channels on the device. The out-
puts are assigned sequentially, so if you se-
lect 13–14, then input 13 will be mapped
to channel 1, and 14 to channel 2.
Baud Rate for Bus 1 and Bus 2
This function lets you set the baud rate for bus 1 and bus 2. The two buses can be configured separately. Flip
the switches up and down according to the diagram to set the baud rate for each bus.
Front Panel
DIP Switch
Menu
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
Hardware
Software
Mode
Mode
particular method. This table lists how each
Click
parameter may be accessed and configured.
Supervisor
The final row on the table refers to configu-
Yes
ration modes. The DIP switches are used
Yes
to choose between Hardware and Software
modes. If any of the switches are on, that
No
particular parameter is set to Hardware
Yes
mode and only the DIP switches can be used
Yes
to change its configuration options. If no
Yes
switches are on for a particular parameter,
Yes
it is in Software mode and the front panel
Software
menu and Click Supervisor must be used to
Mode
configure it.
Input Mapping
Click
Click
112
114
SW
SW
SW
1–4
1–2
5–8
3–4
9–12
5–6
13–16
7–8
17–20
9–10
21–24
11–12
25–28
13–14
Click
112
Baud Rate
15–16
17–18
19–20
21–22
23–24
25–26
27–28
Bus 1
Bus 2
SW
9600
19200
38400
57600