REMOTE UP/DOWN CONTROL INSTALLATION (optional)
When to use the Remote UP/DOWN Control
The Remote UP/DOWN Control should be used when your cooktop
has a burner that is within 4 inches of the UP/DOWN Button on the
downdraft chimney.
The Remote UP/DOWN Control can be used for convenient UP/DOWN
operation of the downdraft chimney (even when a burner is more
than 4 inches from the UP/DOWN Button of the downdraft chimney).
How to use the Remote UP/DOWN Control
Do not place the remote control where it will interfere with cooking,
where hot pans could be set, or where hot liquids could be spilled
on the control.
The Remote UP/DOWN Control disables the UP/DOWN function of
the UP/DOWN Button on the downdraft chimney.
Installation
1. Using the template at right, lay out the 3-hole pattern on the
counter top. Mark the centers of the three holes to be drilled.
2. Carefully drill the three holes through the counter top. Be careful
not to damage or chip the counter top surface when drilling the
holes.
3. Remove the control from the plastic bag. Line the control up with
the three holes and position the control so it is parallel with the
front of the counter top.
4. Remove the two nylon thumbnuts from the plastic bag and thread
onto the two studs on the control from below the counter top.
Hand tighten only.
WARNING: To reduce the risk of burns or ignition of cloth-
ing by reaching across burners, the remote control must
be mounted at least 4" away from any cook top burner.
5. Remove the blower, clamp channels, and gearmotor cover from
downdraft (see"Prepare the Downdraft" on page 5). Remove the
large panel to expose the downdraft's wiring.
6. At the lower right hand corner of downdraft, unplug the cable
from the left side of the wiring box.
7. Remove remote cable from the plastic bag and plug into back of
control from below counter top. Route cable through cabinet to
lower right hand corner of downdraft and through the clearance
holes in the side of downdraft and wiring box. Plug cable into
circuit board plug, as shown.
8. Stuff excess cable out of the way, secure the cable so it is not
damaged by items stored in the cabinet, and reassemble down-
draft.
.625
2.000
0.438
DIA. HOLE
1.000
CUT OUT ON DOTTED LINE
CUT OUT ON DOTTED LINE
WIRING
BOX
WIRING
BOX
10
2.000
.625
0.250
DIA. HOLES
DOWNDRAFT
CABINET
FLOOR
REMOTE
CABLE
.750
.750
LOWER
RIGHT
SIDE
OF

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents