WELCOME TO
QUICK START GUIDE
Box Contents
Hose Faucet Timer
Wi-Fi Hub
Quick Start Guide
1) Download the B-hyve App
Search for "B-hyve" and download the
free Android or iOS app. Create an
account to begin timer setup.
Already a B-hyve user? Log in to your
existing B-hyve account and go to devices
under settings to add a new device.
There is a wizard in the app to help
guide you through initial setup.
2) Power and Pair Your Wi-Fi Hub
Write down the MAC address:
12 digit alphanumeric code on the back of the hub.
—— : —— : —— : —— : —— : ——
Hub MAC Address:
Plug the Wi-Fi Hub into an indoor outlet.
Choose an indoor location for your hub
near the outside location of your timer and
within range of Wi-Fi.
Avoid areas where the signal must travel through
more than one wall, dirt, or thick steel barriers.
3) Power Your Hose Faucet Timer
Insert two new AA Batteries*, the timer is now
in pairing mode and will flash a blue light every
5 seconds.
You will also hear two clicks about 6 seconds
apart, this is normal and ensures the valve is
closed before you turn on the water.
Write down the MAC address: 12 digit
alphanumeric code on the bottom of the timer.
—— : —— : —— : —— : —— : ——
Timer MAC Address:
If at any time you need to
re-pair, press the on/off
button quickly 5 times.
*Batteries are sold separately. Replace batteries
when timer flashes a red light every 5 seconds,
or when the app notifies you that batteries
need replacing.
4) Install the Timer
Your timer is now ready to be
used with any product that can be
attached to a standard hose faucet.
Do not place the timer in an
underground valve box.
5) Turn on Your Water
The water must remain on for
the timer to work properly.

Manual Watering

Simply press and hold the on/off
button for 5 seconds to activate
manual watering.
Need to stop watering, even during a
programmed time? Press the on/off
button once to stop watering.
Your B-hyve timer can be programmed using Bluetooth®
or through Wi-Fi with the hub.
Program and operate your
timer even if there is no Wi-Fi
signal available.
Timer
Range: 150 ft without interference
Pressure Operating Range: 10-100 PSI
Temperature Operating Range:
32°F-158°F (0-70°C)
For Outdoor Use With Cold Water Only
Not For Use With Appliances
Do Not Mix Alkaline, Standard (Carbon-Zinc), or
Rechargeable (Nickel Cadmium) Batteries.
Used up or dead batteries must be removed from the
timer and disposed of properly.
Do not dispose of batteries in fire.
Batteries may explode or leak.
FCC Statement: FCC ID: ML6HT25 & ML6-BH1
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC Warning: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device meets the FCC and IC requirements for RF exposure in public or controlled environments.
The end user is advised to maintain a distance 20 cm from the timer and any personnel to ensure
compliance with RF exposure regulations.
IC Statement: IC: 3330A-HT25 & 3330A-BH1
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept
on/off
any interference received, including interference that may cause undesired operation. This Class B digital
apparatus complies with Canadian ICES-003.
Need Help?
If you encounter a problem, please use the following
resources before retuning your B-hyve to the store.
Scan the QR Code for access to a full user manual,
videos, and more.
call us
1-801-299-5555
or visit us at:
mybhyve.com
Make changes from anywhere,
receive instant timer updates,
weather updates, and other
notifications.
Hub
Range: 150 ft without interference
Temperature Operating Range:
32°F-104°F (0-40°C)
Storage Temperature:
-4°F to 140°F (-20 °C to 60 °C)
Humidity Operating Range: 0–90%
Input: 100-240V ~ 50/60Hz 0.2A
Output: 5V-1.0A
For Indoor Use Only
text us
email us
801-905-8260
support@orbitbhyve.com

Advertisement

loading

Summary of Contents for Orbit B-hyve

  • Page 1: Manual Watering

    Wi-Fi Hub Quick Start Guide 1) Download the B-hyve App Your B-hyve timer can be programmed using Bluetooth® or through Wi-Fi with the hub. Search for “B-hyve” and download the free Android or iOS app. Create an account to begin timer setup.
  • Page 2 Guide de demarrage rapide 1) Telechargez l’application B-hyve Votre minuterie B-hyve peut etre programmee a l’aide du BluetoothR ou par Wi-Fi avec la station centrale. Recherchez B-hyve et telechargez l’application iOS ou Android grauite. Creez un compte afin de commencer la configuration de la minuterie.