Advertisement

Quick Links

English
GA1GB.130101.0
2018-01 Index: 07
ATMOS
Chair 21 D
®
MedizinTechnik

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Chair 21 D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Atmos Chair 21 D

  • Page 1 MedizinTechnik English ATMOS ® Chair 21 D GA1GB.130101.0 2018-01 Index: 07...
  • Page 2: Table Of Contents

    Table of contents Introduction ............3 Notes on operating instructions ......3 Function ..............4 Explanation of symbols .........4 For your safety ............5 Intended use ............6 Setting up and starting up .........7 Mounting ...............7 Adjusting the height of the backrest ......9 Adjusting the position of the backrest ....9 Adjusting the seat height........9 Cleaning and disinfection ........10 General information on cleaning and...
  • Page 3: Introduction

    These operating instructions contain important notes on how to operate the ATMOS ® Chair 21 D safely, correctly and effectively. Therefore, they are intended not only for new operating personnel to be instructed in its use, but also for use as a reference manual.
  • Page 4: Function

    Chair 21 D (for doctors) the examiner can take optimum position ® during examination of the patient. • The ATMOS Chair 21 D is equipped with a mechanical height adjustment. The seat ® height can be varied between 46 and 62 cm. • The ATMOS Chair 21 D is mobile with 5 load dependent braked double castors ®...
  • Page 5: For Your Safety

    • Please observe the ambient conditions stated in the technical data (chapter 9.0). • Prior to use a visual inspection is required. If any parts are defective the ATMOS ® Chair 21 D may not be used. Please contact your service partner.
  • Page 6: Intended Use

    3.0 Intended use Fig. 1. ATMOS Chair 21 D ® Name: ATMOS Chair 21 D ® Main function: This doctor's chair enables the optimum positioning of the doctor with regard to height and access to the patient. Medical indications /...
  • Page 7: Setting Up And Starting Up

    4.0 Setting up and starting up Mounting Prior to assembly check all parts on their perfect technical condition. Insert the double castors , REF 503.0763.0 into the star base REF 503.0761.0 and check on free rotatability. Fig. 2. Insert the chair column , REF 503.0762.0, into the star base.
  • Page 8 4.0 Setting up and starting up Mount the seat cushion with seat support to the cone of the chair column and ensure a tight fi t. Fig. 5. Fix the backrest support 503.0765.0 to the holder of the backrest Fig. 6. Mount the backrest 503.0744.0 to the backrest support with 2 cylinder head screws M6x20...
  • Page 9: Adjusting The Height Of The Backrest

    4.0 Setting up and starting up 4.2 Adjusting the height of the backrest The height of the backrest can be adjusted with the adjusting screw Fig. 8. Adjusting screw for adjusting the height of the backrest 4.3 Adjusting the position of the backrest The position of the backrest can be adjusted with the adjusting screw...
  • Page 10: Cleaning And Disinfection

    5.0 Cleaning and disinfection 5.1 General information on cleaning and disinfection Prior to cleaning Medical chairs such as the ATMOS Chair 21 D must be failsafe at all times. ®  The described measures relating to Do not use cleaning and disinfection resp. sterilisation •...
  • Page 11: Recommended Surface Disinfectants

    5.0 Cleaning and disinfection 5.3 Recommended surface disinfectants The surfaces of the ATMOS Chair 21 D can be cleaned / wiped with disinfectants ® containing the following active ingredients: • QAV (quaternary ammonium compounds) 5.4 Recommended disinfectants for the upholstery...
  • Page 12: Maintenance And Service

    ATMOS recommends: Work should be carried out by an authorized ATMOS service partner. This ensures that repairs and testing are carried out professionally, original spare parts are used and warranty claims remain unaffected.
  • Page 13: Spare Parts

    7.0 Spare parts Name 503.0751.0 Seat cushion ATMOS Chair 21 D basic ® 503.0743.0 Seat cushion ATMOS Chair 21 D special colour ® 503.0742.0 Seat cushion ATMOS Chair 21 D white ® 051.0087.0 Hexagon socket screw M 8 X 20 051.0088.0...
  • Page 14: Technical Data

    8.0 Technical data Height adjustment Manual, gas compression spring Seat diameter 33 cm Seat height 46 - 62 cm Maximum weight load 100 kg Ambient conditions Transport / storage Temperature -10...+50°C Humidity without condensation 30...95 % Air pressure 500...1060 hPa Dimensions •...
  • Page 15: Disposal

    In order to guarantee a proper disposal of your old device, please either pass on your old device to your specialised dealer or send it to ATMOS MedizinTechnik for disposal. Before disposal respectively before transport, all parts, which came into contact with the patient must be thoroughly cleaned, disinfected.
  • Page 16 ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Straße 16 79853 Lenzkirch / Germany Phone: +49 7653 689-0 atmos@atmosmed.de www.atmosmed.com...

Table of Contents