Whirlpool GLS3064R S Manual page 13

Hide thumbs Also See for GLS3064R S:
Table of Contents

Advertisement

6.
To convert the gas valves for use with
L.P. gas:
a) Remove the control knobs from the
gas valves.
b) Reach inside the control panel open-
ings with your fingers, and slide
the rubber guards off the gas valve
stems.
c) Using a small screwdriver, unscrew
and remove the bypass jet pins from
the gas valves.
d) Install the L.P. bypass jet pins in the
gas valves until they are just snug. Do
not overtighten the pins.
e) Reinstall the control knobs on the gas
valves.
f) Remove the backing from the L.P. con-
version sticker, and press the sticker
onto the bottom of the cooktop chassis
near the model/serial number label.
Bypass Jet Pin
2-3
7.
To check the burner operation:
a) Turn on the power and gas supply to
the cooktop.
b) Light a burner, and quickly turn the gas
valve from low to high, and then back
to low. Both the high and low flames
should be on steady and not go out.
If the flame should go out at the high
or low setting, it should automatically
reignite.
c) Repeat the previous step for the re-
maining burners.
d) Reinstall the cooktop grates.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gls3665r s

Table of Contents