CHERUBINI CLIMA PLUS RX Instructions Manual

Rolling shutters with tilting mechanism with/without coupling system or opening of the slats
Table of Contents

Advertisement

Quick Links

CLIMA PLUS RX: tapparelle con meccanismo di basculamento
CLIMA RX: tapparelle con meccanismo di basculamento
CLIMA PLUS RX: rolling shutters with tilting mechanism
with/without coupling system or opening of the slats
CLIMA RX: rolling shutters with tilting mechanism
CLIMA PLUS RX
CLIMA PLUS RX
avec/sans crochet d'attache ou d'ouverture des lames
CLIMA RX
sans crochet d'attache ou d'ouverture des lames
CLIMA PLUS RX: persianas con mecanismo de basculación
CLIMA RX: persianas con mecanismo de basculación
ISTRUZIONI - INSTRUCTIONS - EINSTELLANLEITUNGEN
CLIMA PLUS RX
CLIMA RX
con/senza aggancio o apertura delle lame
senza aggancio o apertura delle lame
without coupling system or opening of the slats
:
Rollladen mit Kippmechanismus
mit/ohne Einhaken oder Lamellenöffnung
:
CLIMA RX
Rollladen mit Kippmechanismus
ohne Einhaken oder Lamellenöffnung
:
volet avec mécanisme de basculement
:
volet avec mécanisme de basculement
con/sin enganche o apertura de las lamas
sin enganche o apertura de las lamas
INSTRUCTIONS - INSTRUCCIONES
I
GB
D
F
E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLIMA PLUS RX and is the answer not in the manual?

Questions and answers

Summary of Contents for CHERUBINI CLIMA PLUS RX

  • Page 1 CLIMA PLUS RX CLIMA RX CLIMA PLUS RX: tapparelle con meccanismo di basculamento con/senza aggancio o apertura delle lame CLIMA RX: tapparelle con meccanismo di basculamento senza aggancio o apertura delle lame CLIMA PLUS RX: rolling shutters with tilting mechanism...
  • Page 3: Table Of Contents

    TRANSLATION OF THE ORIGINAL INSTRUCTIONS Table of contents How to prepare the motor ......................p. 43 Electrical connections ........................ p. 44 CHOICE OF THE PROGRAMMING MODES To be read before starting the programming! . p. 45 Motor programming from the remote control ..............p. 46 Compatible remote controls / Key to symbols ................
  • Page 4: How To Prepare The Motor

    HOW TO PREPARE THE MOTOR STOP RING NUT ADAPTOR DRIVING PULLEY STOP RING NUT 1. Insert the adaptor in the stop ring nut mating the groove with the reference notch and push till they touch. 2. Fix the driving pulley on the motor pin until the stop pin clicks.
  • Page 5: Electrical Connections

    ELECTRICAL CONNECTIONS - In order to prevent dangerous situations or malfunctioning, the electrical command elements wired to the motor must be sized according to the motor’s electrical features. - Means for disconnection must be incorporated in the fixed wiring in accordance with the national installation standards.
  • Page 6 CHOICE OF THE PROGRAMMING MODES: RADIO - WHITE WIRE - WHITE WIRE with the radio function active The motor may be programmed using 3 modes: - RADIO PROGRAMMING: Once the programming has been completed the motor enables use either by white-wire, by radio, or using both modes (radio/wire). - WHITE WIRE PROGRAMMING: ·...
  • Page 7: Motor Programming From The Remote Control

    MOTOR PROGRAMMING FROM THE REMOTE CONTROL COMPATIBLE REMOTE CONTROLS LED - Skipper Skipper Skipper Skipper Skipper Skipper Display - Skipper Skipper Skipper Skipper Skipper stop Channel selector down Activating/ Deactivating the Sun sensor Check the specific Skipper instruction book Skipper GIRO GIRO Wall stop...
  • Page 8: Command Sequences Example

    COMMAND SEQUENCES EXAMPLE Most of the command sequences have three distinct steps, at the end of which the motor indicates if the step has been concluded positively or not, by turning in different ways. This section is provided to demonstrate the motor indications. The buttons must be pressed as shown in the sequence, without taking more than 4 seconds between one step and the next.
  • Page 9: Function Open/Close Programming Remote Control

    FUNCTION OPEN/CLOSE PROGRAMMING REMOTE CONTROL SKIPPER PLUS - SKIPPER LUX - SKIPPER P-LUX To prevent accidental changes to the programming of the motor during the daily use of the remote control, the possibility of programming is disabled automatically 8 hours after sending the last sequence (A+B or B+C).
  • Page 10 FUNCTION OPEN/CLOSE PROGRAMMING REMOTE CONTROL SKIPPER - SKIPPER WALL - SERIES GIRO To prevent accidental changes to the programming of the motor during the daily use of the remote control, the possibility of programming is disabled automatically 8 hours after sending the last sequence (A+B or B+C).
  • Page 11: Setting The First Remote Control

    SETTING THE FIRST REMOTE CONTROL This operation can only be performed when the motor is new, or after a total delete of the memory. During this step, power up only one motor at time! T1: First remote control to be set T1 (2 sec) AUTOMATIC DISABLING OF THE FIRST REMOTE CONTROL SETTING FUNCTION...
  • Page 12: Example 1: Setting First The Opening Position

    EXAMPLE 1: Setting first the opening position SETTING THE OPENING POSITION If the rolling shutter is completely open, you have first to drive it down by around 20 cm. Hold the button A or C pressed and drive the rolling shutter to the opening position. With physical stops: press button A or C until the motor stops automatically.
  • Page 13: Example 2: Setting First The Closing Position

    EXAMPLE 2: Setting first the closing position SETTING THE CLOSING POSITION If the rolling shutter is completely closed, you have first to drive it up by around 20 cm. Hold the button A or C pressed and drive the rolling shutter to the closing position. With lockdown hangers: press buttons A or C until the motor stops automatically.
  • Page 14: Mode 2: Limit Switch Setting (Semi-Automatic)

    MODE 2: LIMIT SWITCH SETTING (semi-automatic) To do the settings in this mode the rolling shutter has to be equipped with lockdown hangers in the closing position, but the rolling shutter does not need to have physical stops in the opening position. This mode of setting is helpful in cases where the factory will set the opening position and the closing position will be set automatically during the normal use.
  • Page 15: Setting A Middle Position / Deleting The Middle Position

    SETTING A MIDDLE POSITION This function allows the rolling shutter to be set at a favourite middle position. When this middle position is memorised, you just press the STOP button for 2 seconds and automatically the motor will move the shutter to this position. To memorise the middle position, move the rolling shutter to the desired position and then hold the STOP button down (for about 2 sec) until the motor gives confirmation.
  • Page 16: Closing Force Adjustment

    CLOSING FORCE ADJUSTMENT 40 % 20 % This system is the only one of its kind and it guarantees that rolling shutters (which are equipped with lockdown hangers) remain perfectly closed without any danger of the slats suffering excessive pressure. 10 % The system works in all kinds of applications because of the opportunity of manually adjusting the closing...
  • Page 17: Setting Of Additional Remote Controls / Remote Control Memory Clearing

    SETTING OF ADDITIONAL REMOTE CONTROLS Up to 15 remote controls can be set. Tn: Already programmed remote control Tx: Additional remote control Tx (2 sec) REMOTE CONTROL MEMORY CLEARING It is possible to delete singly all the memorised remote controls. When the last one is deleted the motor initial condition is restored.
  • Page 18: Full Memory Clearing

    FULL MEMORY CLEARING This full memory clearing does not delete the setting of the limit switch. The full memory clearing can be performed in two ways: 1) WITH THE REMOTE CONTROL Tn: Already programmed remote control Tn (4 sec) 2) WITH THE WHITE WIRE Do this operation only in case of emergency, if all remote controls are no longer operating.
  • Page 19: Special Functions: Short-Term Setting Of A Remote Control

    SPECIAL FUNCTIONS SHORT-TERM SETTING OF A REMOTE CONTROL This function makes it possible to store a remote control temporarily, for example, with the purpose of setting the limit switches during assembly in the factory. A later final saving of the remote control will be possible using the appropriate command sequence (see: “SETTING THE FIRST REMOTE CONTROL”).
  • Page 20: Slat Tilting Mechanism Setting (Remote Control Progr.)

    SLAT TILTING MECHANISM SETTING (Not available on Clima RX) MODE 1 Orientable roller shutter with coupling point for tilting function above the lower limit. Only for roller shutter type Persyroll / Multiroll / Supergradhermetic / Supernova. Not suitable for centralised control units. Not available on motors Ø 35. After having memorised the limit switches, perform the following command sequence: 2 sec At the end of the sequence, wait until the rolling shutter is completely lowered.
  • Page 21 SLAT TILTING MECHANISM SETTING MODE 2 Orientable roller shutter without coupling point with tilting function adjustable below the lower limit. Only for roller shutter type Solomatic. Not suitable for centralised control units. Not available on motors Ø 35. After having memorized the limit switches, perform the following command sequence: 2 sec At the end of the sequence, wait until the rolling shutter is completely lowered.
  • Page 22 SLAT OPENING MECHANISM SETTING MODE 3 Orientable roller shutter with slats opening below the lower limit without adjustable tilting function. Only for roller shutter type Orienta / Rollflap / Biroll / Gelosia / Girasole / Easyroll / Inklina /Estella / Luxor Noon, where the customer doesn’t need to adjust the number of open slats.
  • Page 23: Mode 1 - 2- 3

    SLAT TILTING MECHANISM SETTING (Not available on Clima RX) MODE 4 Orientable roller shutter with coupling point for tilting function above the lower limit. Only for roller shutter type Persyroll / Multiroll / Supergradhermetic / Supernova. Suitable for centralised control units. After having memorized the limit switches, perform the following command sequence: 2 sec At the end of the sequence, wait until the rolling shutter is completely lowered.
  • Page 24 SLAT TILTING MECHANISM SETTING MODE 5 Orientable roller shutter without coupling point with tilting function adjustable below the lower limit. Specific for roller shutter type Rolltek and suitable aswell for roller shutter Orienta / Rollflap / Biroll / Gelosia / Girasole / Easyroll / Inklina / Alika / Luxor Noon, if the customer wants to set the number of opening slats.
  • Page 25: Deleting The Tilting Functions / Slat Tilting Adjustment Impulse

    DELETING THE TILTING FUNCTIONS To deactivate the tilting functions, perform the command sequence: 2 sec SLAT TILTING ADJUSTMENT IMPULSE Use the following sequence to enable the slat tilting adjustment impulse with a double duration (long) compared to what it’s normally set in the factory (short): 2 sec in this way fewer impulses will be needed to adjust the opening of the slats from their minimum to their maximum.
  • Page 26: Notes For The Contemporaneous Use Of The Middle Position

    NOTES FOR THE CONTEMPORANEOUS USE OF THE MIDDLE POSITION AND THE TILTING / ORIENTATION FUNCTIONS In the sections above, situations were discussed in which either only the tilting / orientation function or only the middle position function were to be used. If only one of the functions has been programmed the commands for its use are the same (long B from the UP/DOWN on the remote control, or UP/DOWN on the button panel).
  • Page 27: Motor Programming From The White Wire

    MOTOR PROGRAMMING FROM THE WHITE WIRE KEY TO SYMBOLS Press the Press the UP-button DOWN-button DOWN down short motor DOWN DOWN rotation in one direction Press the buttons quickly according to the sequence indicated long motor rotation in other direction DOWN DOWN Press the buttons quickly according to the sequence indicated.
  • Page 28: Motor Programming From The White Wire

    MOTOR PROGRAMMING FROM THE WHITE WIRE PLEASE NOTE. If the motor is programmed from the white wire without first having memorised at least one remote control, the remote function will be deactivated automatically (to reactivate it, see page 45 - ACTIVATION/DEACTIVATION OF THE REMOTE CONTROL MOTOR FUNCTION).
  • Page 29: Example 1: Setting First The Opening Position

    EXAMPLE N.1 Setting first the opening position SETTING THE OPENING POSITION If the rolling shutter is completely open, you have first to drive it down by around 20 cm. Bring the rolling shutter to the opening position using the UP or DOWN button. (Open position) With physical stops: press UP or DOWN button until the motor stops automatically.
  • Page 30: Example 2: Setting First The Closing Position

    EXAMPLE N.2 Setting first the closing position SETTING THE CLOSING POSITION If the rolling shutter is completely closed, you have first to drive it up by around 20 cm. Bring the rolling shutter to the closing position using the UP or DOWN button. (Closed position) With lockdown hangers: press UP or DOWN button until the motor stops automatically.
  • Page 31: Mode 2: Limit Switch Setting (Semi-Automatic)

    MODE 2: LIMIT SWITCH SETTING (semi-automatic) To do the settings in this mode the rolling shutter has to be equipped with lockdown hangers in the closing position, but the rolling shutter does not need to have physical stops in the opening position. This mode of setting is helpful in cases where the factory will set the opening position and the closing position will be set automatically during the normal use.
  • Page 32: Setting/Deleting A Middle Position

    SETTING/DELETING A MIDDLE POSITION MOVEMENT TO MIDDLE POSITION From the OPENING position From the CLOSING position After the sequence the motor will go into “Dead Man” mode so as to enable the exact adjustment of the middle position desired. To memorise the position chosen, confirm with this sequence: MOVEMENT TO MIDDLE POSITION To bring the shutter to the middle...
  • Page 33: Closing Force Adjustment

    CLOSING FORCE ADJUSTMENT This system is the only one of its kind and it guarantees that rolling shutters (which are equipped with lockdown hangers) remain perfectly closed without any danger of the slats suffering excessive pressure. The system works in all kinds of applications because of the opportunity of manually adjusting the closing force.
  • Page 34: Deleting The Opening And Closing Limit Switch

    DELETING THE OPENING AND CLOSING LIMIT SWITCH From the OPENING position DOWN From the CLOSING position DOWN DOWN DOWN DOWN DOWN After deletion of the limit switches the radio function automatically resets. SPECIAL FUNCTIONS SLAT TILTING OR SLAT OPENING MECHANISM SETTING OPERATIONAL NOTES - MODE 1-2-3: What is meant by a short command to the button (UP, DOWN) is the pressure on the...
  • Page 35: Slat Tilting Mechanism Setting (Progr. From The White Wire)

    SLAT TILTING MECHANISM SETTING (Not available on Clima RX) MODE 1 Orientable roller shutter with coupling point for tilting function above the lower limit. Only for roller shutter type Persyroll / Multiroll / Supergradhermetic / Supernova. Not suitable for centralised control units. Not available on Ø 35. After having memorised the limit switches, drive the rolling shutter to the opening position and then perform the following command sequence: At the end of the sequence, wait until the rolling shutter is completely lowered.
  • Page 36 SLAT TILTING MECHANISM SETTING MODE 2 Orientable roller shutter without coupling point with tilting function adjustable below the lower limit. Only for roller shutter type Solomatic. Not suitable for centralised control units. Not available on motors Ø 35. After having memorized the limit switches, drive the rolling shutter to the opening position and then perform the following command sequence: At the end of the sequence, wait until the rolling shutter is completely lowered.
  • Page 37 SLAT OPENING MECHANISM SETTING MODE 3 Orientable roller shutter with slats opening below the lower limit without adjustable tilting function. Only for roller shutter type / Rollflap / Biroll / Gelosia / Girasole / Easyroll / Inklina /Estella / Luxor Noon, where the customer doesn’t need to adjust the number of open slats. Not suitable for centralised control units.
  • Page 38: Mode 1 - 2- 3

    SLAT TILTING MECHANISM SETTING (Not available on Clima RX) MODE 4 Orientable roller shutter with coupling point for tilting function above the lower limit. Only for roller shutter type Persyroll / Multiroll / Supergradhermetic / Supernova. Suitable for centralised control units. After having memorised...
  • Page 39 SLAT TILTING MECHANISM SETTING MODE 5 Orientable roller shutter without coupling point with tilting function adjustable below the lower limit. Specific for roller shutter type Rolltek and suitable aswell for roller shutter Orienta / Rollflap / Biroll / Gelosia / Girasole / Easyroll / Inklina / Alika / Luxor Noon, if the customer wants to set the number of opening slats.
  • Page 40: Deleting The Tilting Functions

    DELETING THE TILTING FUNCTIONS To deactivate the tilting functions, perform the command sequence: From the OPENING position From the CLOSING position SLAT TILTING ADJUSTMENT IMPULSE Use the following sequence to enable the slat tilting adjustment impulse with a double duration (long) compared to what it’s normally set in the factory (short): From the OPENING position From the CLOSING position This way fewer impulses will be needed to adjust the opening of the slats from their...
  • Page 41: Command Management From White Wire Up-Down Continuous Movement/ Up-Down Dead Man

    2 sec EU DECLARATION OF CONFORMITY CHERUBINI S.p.A. declares that the product is in conformity with the relevant Union harmonisation legislation: Directive 2014/53/EU, Directive 2011/65/EU. The full text of the EU declaration of conformity is available upon request at the...