AEG SCB61816NS User Manual page 11

Hide thumbs Also See for SCB61816NS:
Table of Contents

Advertisement

Available languages

Available languages

Problem
There is too much frost and
ice.
The compressor does not
start immediately after
pressing the FROSTMATIC,
or after changing the tem-
perature.
Water flows on the rear
plate of the refrigerator.
Water flows inside the refrig-
erator.
Water flows on the floor.
Temperature cannot be set.
The temperature in the ap-
pliance is too low/too high.
Possible cause
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The door is not closed cor-
rectly.
The FROSTMATIC is
switched on.
The door is not closed cor-
rectly or the gasket is de-
formed/dirty.
This is normal, no error has
occurred.
During the automatic de-
frosting process, frost
melts on the rear plate.
The water outlet is clog-
ged.
Food products prevent
that water flows into the
water collector.
The melting water outlet is
not connected to the
evaporative tray above the
compressor.
The FROSTMATIC or
COOLMATIC function is
switched on.
The temperature regulator
is not set correctly.
The door is not closed cor-
rectly.
ENGLISH
Solution
Wait some hours and then
check the temperature again.
Refer to climate class chart on
the rating plate.
Allow food products to cool to
room temperature before stor-
ing.
Refer to "Closing the door".
Refer to "FROSTMATIC func-
tion".
Refer to "Closing the door".
The compressor starts after a
period of time.
This is correct.
Clean the water outlet.
Make sure that food products
do not touch the rear plate.
Attach the melting water out-
let to the evaporative tray.
Switch off FROSTMATIC or
COOLMATIC manually, or wait
until the function resets auto-
matically to set the tempera-
ture. Refer to "FROSTMATIC
or COOLMATIC function".
Set a higher/lower tempera-
ture.
Refer to "Closing the door".
11

Advertisement

Table of Contents
loading

Table of Contents