10. Turn On the Air Ionizer / Ozone Function And Deactivate The Mist Spray
Function:
When the power of the device is turned o , press the air ionizer / ozone
switch for 3 seconds, release after hearing the "beep", then the air ionizer /
ozone function is activated.
60
Press
3 seconds
50
70
RH
Beep ~~~
11. Low-water Level Warning Light:
When the water level is too low, the low-water level warning light will be
lighted and the device will be shut down automatically. Please follow Step 3
to add some water, and then turn on the power again.
12. Turn O The Power:
Under the continuous spray mode:
Press the power/time setup swtich for 3 seconds, release after hearing the
"beep", then the spray mode swifts to intermittent spray mode. Press again
the power/time setup swtich for 3 seconds, release after hearing the "beep",
then the power is turned o .
Under the intermittent spray mode:
Press the power/time setup swtich for 3 seconds, release after hearing the
"beep", then the power is turned o .
Note:
(1) If the switch doesn't beep or the LED light is not lighted when pressing the switch, please
contact the dealer for repair.
(2) Do not place the device on the surface where it is dangerous, ammable, or slopy, in
order to avoid any danger.
(3) Keep the sharp object away from the mist spray hole, in order to avoid causing any
scratch or damage to the mist spray module.
9
60
50
70
RH

Cleaning Instructions

Please follow Steps 1~14 for regular cleaning. If there is no essential oil to be
added into the water tank, please skip Steps 10 & 11.
If the device is not in use for a long period of time or the mesh module is blocked,
please add drinking water, turn on the power to activate mist spray function, and
follow the cleaning Steps 1~14. If the mist still cannot be sprayed out of the
device, please contact the dealer for assistance.
1. Please refer to the Operating Instructions Steps 1 & 2.
2. Pour out the remained drinking water inside of the large & small water
tanks.
3. Add medicinal alcohol into the small water tank until it's 80% full.
4. Engage the water tank cover with the latch, and press it tightly.
5. Press the power/mist time setup switch to activate the mist spray function,
and adjust the mist spray volume to the largest.
Press
4hr
3 seconds
2hr
8hr
Beep ~~~
1hr
6. The mesh module and its residue will be cleaned throught the mist spray
function
(Keep away from re and other ignition sources during
7. When the low-water warning light is lighted, it indicates that the cleaning is
done (Approx. 20 minutes).