Joinwit JW3116 Manual

Handheld optical light source

Advertisement

Quick Links

Handheld Optical Light Source-JW3116
NOTICE
All the trademarks mentioned in this manual are registered property
of Joinwit. The right to interpret this manual is reserved by Joinwit.
This publication is protected by the copyright laws of the People's Republic of China and
other countries, with all rights reserved. No part of this publication may be reproduced,
stored in a retrieval system, translated, transcribed, or transmitted, in any means manual,
electric, electronic, electromagnetic, or otherwise, without prior explicit written permission
of Joinwit Optoelectronic Technology Co., Ltd.
.............................................................................................
The information contained in this document is assumed to be correct
and current. The manufacturer is not responsible for errors of omissions
and reserves the right to change specifications at any time without
notice.
Shanghai Joinwit Optoelectronic Co.,Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for Joinwit JW3116

  • Page 1 NOTICE All the trademarks mentioned in this manual are registered property of Joinwit. The right to interpret this manual is reserved by Joinwit. This publication is protected by the copyright laws of the People’s Republic of China and other countries, with all rights reserved. No part of this publication may be reproduced,...
  • Page 2 Handheld Optical Light Source-JW3116 Safety Sign: When using the optical power meter, always take bask safety precautions to reduce the harm for the testers, and injury to persons. All the safety sign may not mark in this manual. Warning:Prohibited misconduct and operation, to prevent any improper conduct and operation of the damage.
  • Page 3 Handheld Optical Light Source-JW3116 Safety Advice 1.When the tester use Disposable alkaline batteries, do not charge it. Ensure the correct polarity installation,when replace the battery. 2. When the products are not in use, please remove the batteries and kept separate to avoid instrument damage caused by battery leakage.
  • Page 4: Table Of Contents

    Handheld Optical Light Source-JW3116 Contents Chapter 1 Standard Configuration --------------------------------------------------------------------------------- 1 Chapter 2 Overview --------------------------------------------------------------------------------------------------- 1 Features ------------------------------------------------------------------------------------------------------------ 1 Chapter 3 Specifications ------------------------------------------------------------------------------------------ 2 Chapter 4 Function ------------------------------------------------------------------------------------------------ 3 4.1Front ------------------------------------------------------------------------------------------------------------ 3 4.2 Left Side ------------------------------------------------------------------------------------------------------- 4 4.3 Top -------------------------------------------------------------------------------------------------------------- 5 4.4 Backside ------------------------------------------------------------------------------------------------------- 6...
  • Page 5: Chapter 1 Standard Configuration

    Carry Bag Chapter 2 Overview JW3116 is a handheld optical light source, the new released tester in 2010, designed for the fiber optical network installation, acceptance, and maintenance. Used with JW3216, can provide a accurate fiber network solution. According with client’s requirements,...
  • Page 6: Chapter 3 Specifications

    Handheld Optical Light Source-JW3116 Chapter 3 Specifications Model JW3116 Operating wavelength(nm) 1310/1550 (others specify on requests) Applicable fiber SM ,MM Laser type FP-LD(others specify on requests) Maximum Output Power(dBm) -5(can be adjustable, others specify) <0.5 (adjustable between -5~-12dBm) Adjustable step size(dBm)...
  • Page 7: Chapter 4 Function

    After on the tester, first press to laser on, then press to select the wavelength and display the current wavelength on the left top of the screen. backlight control. JW3116 have two type of backlight control, press to choose one mode: “LDR”...
  • Page 8: Left Side

    Handheld Optical Light Source-JW3116 Rated power: Rated output power Down the rated power Down the rated output power Modulation adjustment/wavelength identifying Laser on. After on the tester, firstly press , to laser on the light source. Short press shift the frequency.
  • Page 9: Top

    Handheld Optical Light Source-JW3116 Connect the AC adaptor with the port 4.3 Top (1) Dust cap In order to protect the optical connector, avoid damage on the connector, so when not in use make sure that you place the dust cap over the connectors.
  • Page 10: Backside

    。 Chapter 5 Operation Instruction 5.1 Ways of power supply JW3116 can be either battery powered or AC adaptor powered, giving total flexibility for most testing sites and situations 5.1.1 AA battery 5-1。...
  • Page 11 Handheld Optical Light Source-JW3116 Battery Power indicate There are 5 Grades for the battery power indication: left 70%~100% electricity left 40%~70% electricity left 30%~40% electricity left 20%~30% electricity。 not enough electricity, left less than 20%,the power meter will be forced power off.
  • Page 12: Power On The Laser Source

    Handheld Optical Light Source-JW3116 AC power supply sign When use the AC adaptor, connect the power plug as pic, and insert to the AC socket. AC adaptor Power Supply Power Plug Notice:Please use only the power supply unit supplied with the tester, use other kind of PSU may cause damage for the instruments.
  • Page 13: Backlight Setting

    Handheld Optical Light Source-JW3116 When the tester is standby, press key can cancel or choos auto-off function.If auto-off fucniton are choosed, the “Auto-off” will display on the left bottom of the screen. 5.3 Backlight Setting After open the optical power meter, long press , choose backlight control mode.
  • Page 14: Output Power

    5.4.2 Laser on the light source. When open JW3116, the laser source still laser off, only after press laser on the diode (5-8 & 5-9)
  • Page 15 Handheld Optical Light Source-JW3116 Press , select the output wavelength, display at the top of the screen. 5-10 Output wavelength 5-10 5.4.4 Output power Every selected wavelength can adjust the output power within the range (-5~-12dBm), and also can load with the output frequency.
  • Page 16: Wavelength Automatic Identification

    270Hz、 330Hz、 1KHz、 2KHz accordingly, which will be shown on the upper right of the LCD in JW3116 light source. In the mean time, the JW3216 power meter will detect the corresponding frequency automatically from JW3116 light source. Please refer to below figure...
  • Page 17: Power Off

    Handheld Optical Light Source-JW3116 270Hz 270Hz 330Hz 330Hz 1KHz 1KHz 2KHz 2KHz JW3116 Light Source JW3216 Power Meter 5-15 Note:Frequency ID and wave ID cannot be operated at the same time. To avoid risk of serious eye damage, please do not look into the optical port of laser source at any time.
  • Page 18: Chapter 7 General Maintenance

    Joinwit. will pay the shipping cost from customer side to Joinwit. and pay the import taxes in China. Customer will pay the shipping cost from Joinwit. to customer side and its local import taxes accordingly.
  • Page 19 Handheld Optical Light Source-JW3116 An important message from JOINWIT JOINWIT guarantees that any information you supply will remain confidential. By returning this card, you will automatically be notified about updates, modifications, and recalibration. CUSTOMER SERVICE Phone: 86-21-51591648 Fax: 86-21-51591519 info@joinwit.com www.joinwit.com...