Download Print this page

Bosch 715ES Service Bulletin page 2

Descaling the heat exchanger
Hide thumbs Also See for 715ES:

Advertisement

18 | G3-13 | 715ES, C800ES, C920ES, C920ESC, 2400ES, 2700ES
14. Run solution through the heater until the solution returning to
the descaling reservoir/bucket comes out clear. Changing to a
fresh solution may be necessary during this process.
15. Properly discard of dirty descaling solution. Disconnect lines A
and C (Fig. 1). Reconnect cold water supply to the water heater.
16. Open cold supply shutoff valve to flush water heater with clean
water. Allow enough water to flow through the heater to
properly flush it. Filling the 5 gallon descaling bucket once
should be sufficient.
17. Close cold water shutoff valve and disconnect line B (Fig. 1).
Reconnect hot water line to the water heater.
18. Plug in power cord and press On/Off button to "On".
19. Open water shutoff valves, and return water heater to service.
Water Quality
Water quality can have an impact on appliance longevity and may
void the manufacturer's warranty.
For water analysis data, call your local water department. If on a
well, have the well water analyzed periodically. If water quality
exceeds one or more of the values specified in Figure 2, Bosch
recommends consulting a local plumber about installing a water
conditioner or softener.
If the tankless water heater is operating in applications where
the outlet temperature exceeds 140°F, a water softening system
is strongly recommended. The higher the set temperature is on
the appliance, the greater the risk for scale/mineral deposits.
Damage from scale/mineral deposits is not covered under
warranty. Refer to manufacturer's limited warranty.
Data subject to change without notice | Printed in the USA | BTC710002307 A | 01.2009
Description
pH
TDS (total Dissolved
Solids)
Total hardness
Aluminum
Chlorides
Copper
Iron
Manganese
Zinc
Service bulletin
Figure 2
Max. Levels
pH
6.5 - 8.5
mg/l or ppm
500
100
gpg or ppm
(6 gpg)
mg/l or ppm
2.0
mg/l or ppm
250
mg/l or ppm
1.0
mg/l or ppm
0.3
mg/l or ppm
0.05
mg/l or ppm
5.0
Bosch Thermotechnology Corp.
50 Wentworth Avenue
Londonderry, NH 03053
Tel: 1-866-642-3198
Fax: 1-603-584-1681
www.boschhotwater.com