Products Overview; Package Contents - CDVI BO600RP Manual

Horizontal & vertical retrofit housing
Hide thumbs Also See for BO600RP:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION MANUAL
BO600RH
Horizontal retrofit housing
Thank you for buying our products and for the confidence
you placed in our company.

1] PRODUCTS OVERVIEW

NFS 61-937.
Pre-assembled.
Fast installation.
Covers previous installation
fixing holes.
Pre-drilled sections (adjustable).
Ergonomic design.
SAA finish (Satin Anodised Aluminium).
Aesthetic.
Suitable for metal, wood
and glass doors.
Ideal for retrofit applications.
Magnets supplied with terminal
blocks.
Groove at the back of the magnet
housing for cable management.
Magnet housing supplied
with cover.
Options: Aluminium rail spacers, Alu-
minium cable tray, Installation on glass
door (UBK25), RAL colour, Monitored
NO/NC, Cut to size.
Holding force: 2 x 300kg,
Dimensions (L x W x D):
- BO600RH = 925 x 105 x 62mm,
- BO600RPSTD = 2190 x 105 x 63mm,
- BO600RP = 2500 x 105 x 63mm.
Magnet housing for frame mount.
Armature housing with end caps
for door mount.
Input voltage: 12/24/48V dc.
Consumption:
- 12V dc = 500mA (per magnet),
- 24V dc = 250mA (per magnet),
- 48V dc = 250mA (for both magnets).
CE Certification
WEEE
-20°C to +70°C
2
cdvigroup.com
EN
BO600RH
63,2
60
30,9
2,3
5
5
5
28,6
REO
8,8
ALMA
7,7
37
BO600RP
105
43,4
43,4
REO
DOOR
DOOR FRAME
OPENING
FIXED LEAF
LEAF
ALMA
MOUNTING
Recommended
Power supplies
ARD212
BS602
ARD24
BS24
INSTALLATION MANUAL
BO600RH
Horizontal retrofit housing
Product Details
Number of 300Kg magnets
Lock section with cover
Architectural handle with fixing cover
End caps for handle
End caps for lock section
RAL colour (option)
Cut to size (option)
3 or 4 magnetic locks (option)
Monitored (option)
2] INFORMATION & RECOMMENDATIONS
Power Considerations
The handle is designed to house electromagnets
with a holding force of 300Kg each. These units can be
supplied by either 12Vdc or 24Vdc depending upon your
preferred choice (48Vdc supplied on special request).
The current required depends on the amount of
electromagnetic locks, and the voltage chosen – please
see Technical Specification, and ensure you have allocated
sufficient power to BO600RH (2500mm housing with 2
magnetic locks) would require: PSU12/2 or ARD2/12 at
12Vdc PSU24/1 or ARD24 at 24Vdc.
Information
The electromagnets are pre-fitted within the lock section.
The armature plates are pre-fitted within the architectural
handle. Both sections are supplied with end caps.

3] PACKAGE CONTENTS

Profiled
Profiled
Box
handle
handle
section
with end
fixings
back-plate
caps
cover
BO600RP
1
1
1
2500 mm
BO600RPSTD
1
1
1
2190 mm
BO600RH 925
1
1
1
mm
BO600RP
BO600RP
BO600RPSTD
2500MM
2190MM
925 MM
2
2
1
1
1
1
2
2
2
2
-
-
-
-
Wiring
Plan your cable routes before commencing installation. We
recommend a maximum distance of 10m from the power
supply to the electromagnetic locks
(to prevent volt
drop). If the distance is greater, then make sure you have
increased the cross section of the cable to compensate.
General Advice
The 2 parts of the architectural housing are designed to
be surface mounted on the door and frame, where they
should be parallel when the door is closed. If there is a
rebate, then it will be necessary to pack out the lower
part to be parallel to the other (Aluminium rail spacer,
Ref: REO). You can also use the PRP800 (Reinforcement
section) or ALMA (Aluminium Cable tray) to reinforce the
housing mounting.
Handle (BO600RP)
You must secure the handle with the 2 screws which
comes with the retrofit housing.
Box
section
End caps
Handle
screw kit
cover
1
2
1
1
1
2
1
1
1
2
-
1
cdvigroup.com
EN
2
1
1
2
2
-
Manual
1
1
1
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bo600rh

Table of Contents