2 Parameters

2.1 Limit Parameters

Main Parameters
Input Voltage(V)
Blocking Power(dBm)
Working Temp.(℃)
Storage Temp.(℃)

2.2 Working Parameters

Main Parameters
Working Voltage(V)
Tx Electrical Level(V)
Working Temp(℃)
Working Frequency Channel(MHz)
TX Current(mA)
Power
RX Current(mA)
Consumption
Sleeping Current(μA)
Max TX Power(dBm)
RX Sensitivity(dBm)
Air Rate(kbps)
Air Rate Range
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd
Value
Min.
Max
0
3.6
-
10
-40
+85
-60
+150
Value
Mi
Typical
Max.
n.
1.8
3.3
3.6
-
3.3
-
-40
25
+85
400
433
525
70
80
90
12
13
14
0.05
0.5
1
16
17
18
-
-135
-
-120
-121
-122
0.1k
-
125
Remarks
Permanent damage occurred when voltage is over 3.6V
Low chance to be damaged for short-distance transceiving
Industrial Grade
Remarks
DC 3.3V-3.6V can guaranty Max TX power
5V TTL could cause permanent damage
Industrial Grade
Applicable for ISM channel
Instantaneous power(could be different due to different Antenna
performance)
Current when module receiving data.
Deep sleep at ultra low power consumption(low frequency)
-
At 0.1 kbps air rate
At 1.2kbps air rate(FSK/FEC)
Adjustable by user