Download Print this page

CONCORD 85701 User Manual page 2

Advertisement

4.3 Parameter introduction
Parameter
%SpO
2
PRbpm
Calorie
Steps
5 Operation guide
5.1 Installation of batteries
Figure 5
1)
Open the battery compartment cover on the back of the device, shown as Figure 5.
2)
Install the two "AAA" Alkali batteries, pay attention to the direction, shown as Figure 6 also see diagram in
bottom of unit.
3)
Install the battery compartment cover, shown as Figure 7 by sliding the cover back onto the unit. Follow the
tabs on the inside of the cover.
Notice
Please make sure the batteries polarities are installed properly, to avoid any damage to the device.
Please take out the batteries if the device is not used for a long time.
Please replace the batteries in time when low-battery appears on the screen.
Please replace two new batteries with same type at the same time.
After replacing batteries, perform sync time with App again.
Notice
Disposal of scrap batteries should follow local regulations about environment.
5.2 Data measurement
1)
Install the two "AAA" batteries properly, then the device will turn on automatically and enter to
"Synchronous Time..." interface.
Figure 8 Synchronous time interface
Notice
In "Synchronous Time..." interface, Bluetooth will be turned on automatically.
2)
Three methods for "Synchronous Time..." interface.
Notice
Before each measurement, make sure the device has
stored for the data. It indicates that the device needs to perform sync time when it displays "Synchronous
Time..." when you first turn the unit on, otherwise if it not synced it will not store measurement results.
The first method:
If you do not want to perform sync time, simply press the button, then the device will enter to "Steps" interface
from "Synchronous Time..." interface.
The second method:
If you do not want to perform sync time, wait for several minutes, then the device will enter to "Steps" interface
from "Synchronous Time..." interface.
The third method:
To sync the time, push the power button, and the device will turn on automatically. When it enters to
"Synchronous Time..." interface, connect it to the App and then it will automatically adjust time.
3)
In the "Steps" interface, fully insert the finger into the probe and the device will automatically enter to
"SpO
" interface from "Steps" interface, shown as Figure 3.
2
Notice
If the time is wrong, the device will not store data.
Fingernails and the luminescent tube should be on the same side.
During use the user's finger should stay still, and limit movement.
4)
Read SpO
and pulse rate value directly from the screen after inserting the finger for about 4~20s, shown as
2
Figure 3. Pull out the finger after your reading appears on the screen. Only one result is stored each time
your finger is inserted.
5)
In SpO
state, screen direction can be changed automatically by changing the direction of your hand.
2
6)
The interface between "Steps" and "SpO
a.
In "Steps" interface, insert the finger to enter to "SpO
b.
In "SpO
" interface, pull out the finger to enter to "Steps" interface, shown as Figure 4
2
Notice
In "Steps" interface, mode Bluetooth will be in "ON" state all the time.
7)
In "Steps" interface for 1 minute, it will automatically enter standby mode.
Notice
In standby mode, the screen does not display any contents, but the pedometer can work normally.
In standby mode, Bluetooth is in "OFF" state.
8)
In standby mode, press Button to turn on screen display and enter to "Steps" interface shown as Figure 4.
Notice
Before uploading steps data, please do sports for 5 minutes at least.
The Pedometer can only upload stored data for the past 24 hours.
5.3 Data upload
1) The device can transmit SpO
, pulse rate, steps and calorie to your iOS or Android phone or tablet using your
2
Wi-Fi connection.
2) In your IOS or Android App Store search for the free PHMS App by Contec Medical systems.
Figure 1
Download the free App to your phone or tablet.
1
Now you can enter your account number. You will use your 10 digit wireless number. As seen in figure 1
2
Your password will be the last 6 numbers of your wireless number. You can check the Auto Login box for the
3
device to automatically log you in each time you open the App.
Once you have logged into the PHMS App you will want to touch the circle in the middle of the screen that
4
says "NewDevice" Figure 2 to add the device to your App.
The App will now search for your device, once the App has been located your device a pop up will appear on
5
your screen as seen in Figure 3. Choose sure and you will now see your Bluetooth Oximeter in the Data section of
the App.
To upload your most recent readings tap on the small grey box located in the left corner under the image of
6
your Oximeter. It will turn orange as it is connecting to the device and green once it has successfully added the
reading to the Data section in the App.
Description
Unit
Oxygen saturation
%
Pulse rate
bpm
Calorie
Calorie
Step
Step
Figure 6
Figure 7
performed a sync time, to insure the accurate time is
" interface can be switched by inserting the finger.
2
" interface.
2
Figure 2
Figure 3
5.4 Set up My info
1) In the "My Info" Tab you can change your password and set up your BMI information.
5.5 Accessories
A. A lanyard, carrying case and protective boot cover
B. Two batteries
C. A User Manual
6 Maintenance
6.1 Routine maintenance
6.1.1 Cleaning and disinfecting
Turn off the device before cleaning. Use medical Alcohol to clean and disinfect the device, let air-dry or clean it
with a dry clean cloth. Avoid any liquid entering to the device.
6.1.2 Maintenance
1)
Keep the device away from dust, high temperature and humidity, and avoid strong shaking and hitting.
2)
When the device needs to clean, please wipe its surface with neutral detergent, avoid using strong corrosive
liquid, like alcohol and gasoline, etc.
3)
Please clean and disinfect the device before using according to the User Manual (6.1.1).
4)
Please replace the batteries in time when low-battery appears.
5)
Please take out the batteries if the device is not used for a long time.
6)
The device needs to be calibrated periodically. It also can be performed at the state-appointed agent or just
contact us for calibration.
6.2 Transportation and storage
A.
The packed device can be transported by ordinary conveyance or according to transport contract. The device
can not be transported mixed with toxic, harmful, corrosive material.
B.
The packed device should be stored in room with no corrosive gases and good ventilation. Temperature:
-40°C~60°C; Relative Humidity: ≤95%; Atmospheric pressure: 500hPa~1060hPa
7 Troubleshooting
Trouble
Analysis of cause
The SpO
or
2
Pulse Rate can
1) The finger is not properly inserted.
not
be
2) The SpO
value of patient is too low to be
2
displayed
detected.
normally
1) The finger is not inserted inside deep
The SpO
or
2
Pulse Rate are
enough.
2) The finger is shaking or the user is
not
displayed
stably
moving.
1) The batteries are drained or almost
The device can
drained.
not be turned
2) The batteries are installed improperly.
on
3) The device's malfunction.
1) Low voltage
The
display
2) The device enters to standby mode
disappears
automatically if there is no operation for 1
suddenly
minute.
Data can not be
1) False time.
stored.
2) Measurement time is too short.
8 Meaning of Symbol
Symbol
Warning – refer to User Manual
Refer to instruction manual/booklet
%SpO
The pulse oxygen saturation(%)
2
PRbpm
Pulse rate(bpm)
Calorie
Calorie
Low-voltage
Battery anode
Battery cathode
IP22
Ingress of liquids rank
Type BF applied part
9 Specification
Display Information
The Pulse Oxygen Saturation(SpO
)
2
Pulse Rate(PR)
Pulse Intensity(bar-graph)
Calorie
Steps
Time
SpO
parameter
2
Measurement range
Pulse parameter
Measurement range
Pedometer
Measurement range
Safety classification
Pulse Intensity
Range
Power supply
Two "AAA" batteries
Dimension and weight
Dimension
Weight
2.782.404(CHS)ESS/1.0
1.4.01.34.040
Solution
1) Insert the finger properly and try
again.
2) Please try several times more; Go to a
hospital for a diagnosis if you are sure
the device works all right.
1) Insert the finger properly and try
again.
2) Please do not move.
1) Please replace the batteries.
2) Please install the batteries again.
3) Please contact the local service center.
1) Please change the batteries.
2) Normal.
1) Sync time.
2) Normal.
Meaning
Display Mode
2-digit digital OLED display
3-digit digital OLED display
bar-graph
OLED display
5-digit digital OLED display
5-digit digital OLED display
Year-month-day hour-minute
OLED display
0%~99% (resolution: 1%)
30bpm~250bpm (resolution: 1bpm)
0~65535 steps (resolution: one step)
Internally powered equipment, type BF applied part
Continuous bar-graph display, the higher display indicates the
stronger pulse.
58mm(L) x 32mm(W) x 34mm(H)
About 52g (including batteries)

Advertisement

loading